130830-03

GC 304 R

Содержание GC 304 R

Страница 1: ...130830 03 GC 304 R...

Страница 2: ...tion 5 2 1 Supplied by GEZE 6 3 Work to be done before installation 6 3 1 Installing the drive 6 3 2 Positioning the sensor 7 4 Installation 8 4 1 Installation without accessories 8 4 2 Installation w...

Страница 3: ...cts as defined in the German Product Liability Act compliance with the infor mation contained in this brochure product information and intended use misuse product performance product maintenance oblig...

Страница 4: ...or combinations with third party products Only original GEZE parts may be used for repair and maintenance work Observe the latest versions of directives standards and country specific regulations in p...

Страница 5: ...the drive Danger of injury during installation through freely moving parts 1 4 Environmentally conscious working When disposing of the door system separate the different materials and have them recycl...

Страница 6: ...o be done before installation GC 304 R 6 2 1 Supplied by GEZE 3 Work to be done before installation 3 1 Installing the drive X X Make sure that the weather hood of the drive is fitted correctly and ea...

Страница 7: ...se of sliding curved sliding folding and revolving doors Ideally the flow of people will walk directly towards the sensor If the scanning area does not cover the entire opening width or if the flow of...

Страница 8: ...ibrations X X Do not cover the sensor X X Keep away from fluorescent lamps X X Keep away from moving objects 4 1 Installation without accessories X X Remove the rear panel 1 2 3 X X Glue the sensor dr...

Страница 9: ...9 Installation GC 304 R X X Insert the cables and route them properly X X Wire up see Section 4 4 Cabling on page 13 X X Attach the weather hood...

Страница 10: ...Installation GC 304 R 10 4 2 Installation with ceiling installation set 128 mm 190 mm 62 mm DOOR SENSOR ANTENNA 1 1 3 2 2 4 5 5 3...

Страница 11: ...11 Installation GC 304 R 6 7 7 4 30 30 0 8 9 10 5...

Страница 12: ...Installation GC 304 R 12 4 3 Installation with rain cover 1 2 1 3 4 4 2 5 6 7 8 3...

Страница 13: ...iagrams for the drives Upon activation the output of the GC 304 R is closed 24V applied to the KI input X X Set the type of contact for KI and KA to normally opened contact WH YE BN GN 80 mA UB UB GC...

Страница 14: ...Commissioning GC 304 R 14 5 Commissioning 0 0 1 1 1 2 15 15 0 2 2 3 3 3 2 2 m 0 0 1 1 1 2 2 2 3 30 45 15 2 2 m 0 0 1 1 1 2 2 2 3 3 3 2 2 m 0 0 1 1 1 2 2 2 3 3 3 2 2 m 4 m x 2 m 2m x 2 5 m 1 2 3...

Страница 15: ...rection even in the case of persons with limited mobility uni WEG detection of direction away from the sensor Output config Normally opened contact Normal ly closed contact Hold open time 0 5 sec 1 se...

Страница 16: ...ect Cause Elimination The door remains closed The LED is off The power supply is off X X Check cabling and voltage of the power supply The door controller parameter F2 is set to value 3 closed X X Set...

Страница 17: ...the immunity filter In interlocking door systems the sensor detects the move ment of the opposite door X X Change the antenna angle X X Replace the antenna X X Increase the immunity filter The LED fl...

Страница 18: ...tial free relay contacts Max switching voltage 42 V AC DC Max switching current 1 A resistive Max switching power 30 W DC 60 VA AC Installation height from 1 8 m to 4 m Protection rating IP54 Temperat...

Страница 19: ...19 Accessories Spare parts GC 304 R 9 Accessories Spare parts Material no Remote control 100061 Ceiling installation kit 130653 Rain cover 130654...

Страница 20: ...njin Co Ltd Branch Office Beijing E Mail chinasales geze com cn www geze com cn France GEZE France S A R L E Mail france fr geze com www geze fr Hungary GEZE Hungary Kft E Mail office hungary geze com...