background image

 

 

COMPACT 50M-230 · TOTEM 50M-230 INSTRUCTION MANUAL 

 

 

 

 

No.

 

DESCRIPTION

 

CODE

 

No.

 

DESCRIPTION

 

CODE

 

 

 

 

 

 

 

 

M-4x12 DIN. 912 SCREW 

805400035 

12 

CONNECTION BOX 

000201503 

PUMP BODY COVER 

003504000 

13 

SWITCH 

000206017 

58x3 NBR JOINT 

803101061 

14 

FAN 

000201504 

F211 ROLLER 

000002210 

15 

FAN COVER 

000201507 

5-BLADE SET 

000002109 

16 

0.25 kW MOTOR 

000201502 

SEGER RING INT.30 

800303012 

17 

M-6x126 STUD 

000201506 

7 PUMP 

FILTER 

003502001 

18  BEARING 

804603004 

BYPASS VALVE 

805606102 

19 

OUTSIDE RETENTION RING 

804600013 

12x26x7 RETAINER 

804600012 

20 

IRON-50 230 V BYPASS SPRING 

000002007 

10 

4x4x10 SHAFT KEY 

000002002 

21 

IRON-50 230 V PUMP BODY 

003503002 

11 

3 m 230 V CONNECTION CABLE WITH INJECTED PLUG 

800900010 

 

 

 

 

TECHNICAL SPECIFICATIONS

 

- IRON-50 230 V pump of grey foundry with filter built-in. Self-suction.

 

- Eccentric with self-adjusting blades

 

- With bypass recirculation

 

- Motor: 0.25 kW 230 VAC self-ventilated 50/60 Hz single-phase

 

- Noise level: L

EQA

 < 85 dBA (1 m) 

- Continuous duty – IP-55 Protection

 

- Consumption: 1.2-2 A

 

- 3000 rpm

 

- Bypass pressure: 2-2.5 bar

 

- Connection through  F1” threads and flanges

 

- It has a self-cleaning steel filter of 350 µm (micron)

 

 

- NOTE: When using an automatic nozzle, the flow will be reduced.

 

 

 

FLUID COMPATIBILITY 

 

The IRON-50 230 V pumps are especially for the diesel transfer; they must not be used to transfer other liquids.

 

This pump is suitable for its use on the agriculture, building, public works and industry.

 

 

Содержание Compact 50M-230

Страница 1: ...ding to possible dangers The instruction manual must be considered as a part of it and keep it for future inquiries during all its working life We suggest keeping it in a dry and protected place The m...

Страница 2: ...must be fixed by 4 point with M8 screws with its own washers Please see the drawing COMPACT MSGM KIT FIXATION The COMPACT must be fixed in a pedestal or wall support with M6 screws The hole placing de...

Страница 3: ...be determined whether the responsibility is from the manufacturer the user the installer or the delivery transport 3 The warranty does not cover Inadequate use negligence corrosion abuse manipulation...

Страница 4: ...21 IRON 50 230 V PUMP BODY 003503002 11 3 m 230 V CONNECTION CABLE WITH INJECTED PLUG 800900010 TECHNICAL SPECIFICATIONS IRON 50 230 V pump of grey foundry with filter built in Self suction Eccentric...

Страница 5: ...s of dirt in filter problem in suction line or in delivery the bypass is blocked blade friction blade or roller wear dirtiness on the red adaptor disassemble and clean the filter verify suction line t...

Страница 6: ...2 MEASURING BOX SUPPORT 320002006 15 M 5x22 DIN 912 SCREW 805400008 33 GEAR MEASURING UNIT PINION 320002005 16 RESET DRIVE 320005001 34 D 7 x D 4x6 SLEEVE 320004016 17 D 4 2x9 5 DIN 7981 ZINC PLATED S...

Страница 7: ...ted 2 4 To make this operation take out the plug 4 and turn the screw 6 clockwise Then the flow percentage decreases If you turn it anticlockwise it increases A complete turn varies the measurement mo...

Отзывы: