Gesan G 10 TF V Скачать руководство пользователя страница 1

 

 

INSTRUCTION 

MANUAL

 

 

 
 
 
 
 
 
 

MODELS: 

G 3000 H 
G 5000 H 
G 7000 H 
G 12000 H 
G 5 TF H 
G 7 TF H 
G 12 TF H 
 
G 3000 V 
G 5000 V 
G 7000 V 
G 10000 V 
G 12000 V 
G 5 TF V 
G 7 TF V 
G 10 TF V 
G 12 TF V 
 

Содержание G 10 TF V

Страница 1: ...INSTRUCTION MANUAL MODELS G 3000 H G 5000 H G 7000 H G 12000 H G 5 TF H G 7 TF H G 12 TF H G 3000 V G 5000 V G 7000 V G 10000 V G 12000 V G 5 TF V G 7 TF V G 10 TF V G 12 TF V...

Страница 2: ......

Страница 3: ...o perform maintenance in ideal conditions Please keep this manual at hand for consultation at all times and ensure it is included with the machine should it be re sold GRUPOS ELECTROGENOS GESAN S A is...

Страница 4: ...Generators sets GESAN Petrol INDEX SAFETY PRECAUTIONS GENERAL DESCRIPTION CONTROL CARDS LABELS BEFORE OF OPERATION OPERATION HANDLING AND STORAGE MAINTENANCE WIRING DIAGRAMS TROUBLESHOOTING...

Страница 5: ...ried out by a qualified electrician in accordance with applicable standards and regulations A poorly made connection may cause current returns which could lead to the electrocution of anybody working...

Страница 6: ...n cause severe burning Wear protective clothing and a protective mask If electrolyte comes into contact with skin wash with water If electrolyte comes into contact with eyes wash eyes with water for a...

Страница 7: ...Generators sets GESAN Petrol GENERAL DESCRIPTION STATIONARY MOBILE...

Страница 8: ...mains fails and generator parameters are O K the generator lights will come on Three seconds later the mains contactor will open and the generator contactor will close The lights will illuminate Up t...

Страница 9: ...is O K the load will be returned to mains MANUAL OFF RESET Shuts down the generator and cancels all alarm signals mains contactor closed The lamp lights up SERV 1 START The load is supplied by the mai...

Страница 10: ...light will flash POTENTIOMETERS Factory adjusted values Potentiometer 1 Adjusts generator voltage monitor 200 250 V Potentiometer 2 Adjusts generator frequency 48 54 Hz Potentiometer 3 Adjusts min mai...

Страница 11: ...Generators sets GESAN Petrol Flow chart for operation of an emergency automatic generator set...

Страница 12: ...r generator you will find the following labels LABEL 2 LABEL 3 EARTH LABEL 4 ELECTRICAL HAZARD LABEL 5 For your safety and the safety of the others please replace immediately all these labels in case...

Страница 13: ...d can harm the engine If using these types of oils check the oil level ona more regular basis If using oils SAE30 below 4 C 40 F start up will be more difficult and can harm the engine due to lack of...

Страница 14: ...Fill the fuel tank where there is sufficient ventilation and with the engine is switched off Do not smoke or allow sparks or flames in the area where the engine is refuelled or where fuel is stored Do...

Страница 15: ...ect equipment using a voltage different from that supplied by the generator set It is not advisable to use this generator set for equipment such as television sets hi fi systems computers etc If an el...

Страница 16: ...e that the machine is ventilated sufficiently for the engine to run d Allow enough space for supervision servicing and maintenance We recommend that at least 1 metre is left free around the machine CO...

Страница 17: ...and control cables 3 Check that the circuit breaker inside the control panel is disconnected 4 Check oil and radiator water levels Fill if necessary 5 Check fuel level 6 Connect up the battery first...

Страница 18: ...engines with choke push the lever in For automatic start or start up via signal the choke is automatic ELECTRIC START WARNING a Check that nothing is connected to the generator set outputs b Turn the...

Страница 19: ...e does not start up release the key and wait ten seconds before trying again STOPPING THE ENGINE MANUAL START UP a Disconnect all apparatus connected to the generator output b Use the choke where fitt...

Страница 20: ...tied to the chassis as shown on the diagram in fig 1 It is important that the slings are secured firmly to the chassis and that they do not give For skid baseframes with a seat form should be loaded u...

Страница 21: ...the generator set is not to be used for more than six months drain the engine oil and remove the oil filter Replace when the set is to be used again c Remove injectors and pour a small amount of oil...

Страница 22: ...s or every 50 hours Every 6 months or every 100 hours Annually or every 300 hours Engine Oil Check level Change Air filter element 1 Check Clean Sediment cup Clean Oil filter Replace At 200 hours Spar...

Страница 23: ...other flammable liquids to clean the air filter elements Such liquids can catch fire and lead to the deterioration of said elements ATENCION Do not use the generator set without air filter as this ca...

Страница 24: ...ush Do not clean by sanding c Measure the distance between the electrodes with thickness guage This should measure between 0 7 and 0 8 mm If an adjustment needs to be made simply turning the lateral e...

Страница 25: ...Generators sets GESAN Petrol WIRING DIAGRAM WIRING DIAGRAM PETROL AUTOMATIC 400 230 V DIAGRAM N 1337...

Страница 26: ...Generators sets GESAN Petrol WIRING DIAGRAM PETROL MANUAL 400 230 V DIAGRAM N 1029...

Страница 27: ...Generators sets GESAN Petrol WIRING DIAGRAM PETROL AUTOMATIC 230V DIAGRAM N 1027...

Страница 28: ...Generators sets GESAN Petrol WIRING DIAGRAM PETROL MANUAL 230V DIAGRAM N 1376...

Страница 29: ...fuel circuit 7 Ventilate Varying speed 1 Zip caught 2 Check and consult technician 2 High oil level 2 Check and adjust level Black smoke 1 Air filter blocked 1 Replace 2 Incomplete runninng in 2 Chec...

Страница 30: ...pacity Tension too low without load 1 Diodes or varistor damaged 1 Change 2 Faulty winding 2 Check and change 3 Capacity condensor too low 3 Check capacity 4 Potentiometro not set to maximum 4 Set to...