![Gerus Gerupress HP20 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/gerus/gerupress-hp20/gerupress-hp20_operating-manual_2217290012.webp)
GERUS
Seite/ page 12 von/ of 12
5 Technical data
Air pressure (pB):
1,5
– 7,0 bar (pBmax = 15,0 bar)
Output pressure (pA):
2000 bar (max. pressure for permanent
operating)
Test pressure (pprüf):
2000 bar (test operating)
Gadget connections:
Output pressure:
CEJN high pressure coupling
(type series 116)
Air pressure:
compressed air connection
9mm
Masses:
empty:
42 kg
filled:
57 kg
Dimensions:
height:
900 mm
length:
340 mm
width:
320 mm
Volume of tank:
15 l (dm³)
Performance and consumption of air:
0,8 l/ min for 5 bar compressed air
6 After-Sales service and self-help
If the pressure at pressure gauge
F
doesn’t remain constant and drops (as described under point
2.1.
12.), the pump is not air-tight or the decompression valve
B
is not fully closed.
In most cases, this is due to the fact that the O-rings are old/worn-out. It is possible to exchange
the O-rings.
It is recommendable to have the pump overhauled by its manufacturer
GERUS APPARATEBAU GmbH & Co. KG,
Engelschalkstraße 16
D-86316 Friedberg
Tel.: 0049
– (0)821 - 588 662-0
FAX: 0049
– (0)821 - 588 662-10