P.14
型號
Model
MAC-10
電壓/頻率
Voltage / Frequency
220-240 V / 50 Hz
製冷能力
Cooling Capacity in BTU
10,000 BTU / hr
製暖能力
Heating Capacity in BTU
10,000 BTU / hr
匹數
Cooling Capacity in HP
1 .1
匹
HP
電流
Current
4.95 A
空氣流量
Airflow Volume
400 m³/ h
淨重
Net Weight
23.0 kg
機身尺寸
Dimensions
(H) 730 (W) 320 (D) 360 mm
技術規格
TECHNICAL SPECIFICATIONS
常見故障及處理
TROUBLESHOOTING
故障現象
Phenomenon
檢查要點
Possible Causes
處理方法
Solution
不能運作本機。
Machine cannot work.
已關機。
Power off.
開機。
Power on.
「水滿」顯示燈在顯示屏上閃動。
“
Water Full” indicator flashes on screen.
排水。
Drain water out.
已達之前所設定之定時關機時間。
Timer-off turns on.
待關機3分鐘後重新開機。
Wait for 3 minutes, then restart it.
本機經常自動重開。
Machine auto-restarts
frequently.
陽光直射。
Direct sunlight.
拉窗簾。
Draw the curtains.
開啟了門和窗,或室內有很多
熱量來源。
Door and windows are open;
many heat sources exist in the room.
關門及窗,清除熱源。
Close the door and windows, remove
heat sources.
進氣口或出氣口被阻塞。
Air inlet or air outlet is blocked.
清除阻礙。
Remove blockage.
過濾網太骯髒。
Filters are too dirty.
清潔或更換過濾網。
Clean or replace filters.
操作時聲音太大。
Too noisy.
本機並非放於平坦地面。
Machine is not put on flat ground.
將本機置於平穩地面,避免搖晃。
Place it on flat and solid ground to
avoid shaking.
壓縮機不運作。
Compressor does not
work.
壓縮機正在自動延遲啟動以保障
安全。
Compressor time-delay protection
turns on.
待3分鐘後,當壓縮機溫度下降,
再重新開啟本機。
Wait for 3 min until the compressor cools
down. Then restart the machine.
注意:如問題持續發生,請關機及拔除電源插頭,並送回本公司維修。
Note: If the problem persists or other abnormal situations occur, turn off the machine and pull out the plug. Then contact our Repair Centre for help.
使用中如發現本機操作上有問題,請依照下表進行檢查。
When you run into any problems operating this product, use the table below to troubleshoot the problems.
產品規格及設計如有變更,恕不另行通知。
中英文版本如有出入,一概以英文版為準。
Specifications are subject to change without prior notice
.
If there is any inconsistency or ambiguity between the English version and the Chinese version, the English version shall prevail.