background image

Operating Instructions

X4 atom free connect

Version: 1.2 (2018-10-12) - en-us

[email protected]

www.germanlightproducts.com

Содержание X4 atom free connect

Страница 1: ...Operating Instructions X4 atom free connect Version 1 2 2018 10 12 en us Support germanlightproducts com www germanlightproducts com ...

Страница 2: ... Set up device 9 7 Operation 11 7 1 Recharge battery 11 7 2 Switch on the device 11 7 3 Establish wireless connection 11 7 4 Control device 12 7 5 Menu structure 12 7 5 1 DMX start address 12 7 5 2 DMX LED start address 12 7 5 3 DMX channel layout 12 7 5 4 Special 17 7 5 5 Self test program 18 7 5 6 Live time 18 7 5 7 Set DMX mode 19 7 5 8 Reset 19 7 6 Switch off device 19 8 Cleaning and maintenan...

Страница 3: ...rd with a medium level of risk that may result in severe injury or death if it is not avoided Attention Risk of equipment damage Advice Indicates a helpful note in the current context One or more bolded words indicate a term that can be found exactly the same on the product One or more italicized words indicates an index entry or an important technical term 1 Instructions are numbered As are resul...

Страница 4: ...ent or expose it to severe mechanical pressure The equipment can sustain heavy damage from the impact Keep equipment safe from moisture splashing water and heat exposure Maintain an adequate distance from surfaces sensitive to hear min 20 cm Regularly check equipment for damage If damaged turn the equipment off and fully dis connect from the power supply Contact customer service or retailer Mainte...

Страница 5: ...t and storage Attention Do not drop equipment or expose it to severe mechanical pressure The product can sustain damage from the impact Only store equipment in dry areas Use the supplied or appropriate packaging material for storage and transport To lift the device grasp the casing with both hands ...

Страница 6: ...e of delivery for completeness after unpacking Check device for visible damage Number component Description 1 x X4 atom free connect 1 x Power cable To charge the battery 1 x Operating instructions Advice Order optional accessories directly from your specialist retailer List to be found online at www germanlightproducts com ...

Страница 7: ... view 1 2 3 4 2 5 6 7 Image 1 Description X4 atom free connect 1 Thumb screw 5 Antenna 2 Fixing rails 6 On off latching switch 3 XLR cable 7 2 x safety eyelet 4 XLR connection Underside 1 2 3 3 3 3 4 Image 2 Description underside 1 Mains connection 3 4 x rubber feet 2 Firmware Update Cover 4 3 x M10 threaded connections ...

Страница 8: ...fixing rails of the X4 atom free connect until the release buttons click into place 3 Plug the XLR cable into the XLR socket on the back of the X4 atom The X4 atom is assembled on the X4 atom free connect click click Image 3 Assembly X4 atom Swivel the X4 atom 1 Loosen the side thumb screw with just 1 to 2 turns until the fixation is released 2 Swing the X4 atom into the desired position The swing...

Страница 9: ... ground Place the device on the ground with 4 rubber feet The device is now ready for use Fix the device sideways Conditions Half coupler M10 threaded screws max 11 mm long 1 Screw a half coupler with M10 threaded screws on the underside of the X4 atom free connect in one of the M10 threaded connections 2 Attach the half coupler to a suitable scaffold with the X4 atom free connect 3 Secure the X4 ...

Страница 10: ...ew a half coupler with M10 threaded screws on the underside of the X4 atom free connect into the center M10 threaded connection 2 Attach the half coupler to a suitable scaffold with the X4 atom free connect 3 Secure the X4 atom free connect using the safety eyelets The device is now ready for use ...

Страница 11: ...n the device Conditions The battery is charged Press the on off switch so that it clicks into place After a few seconds the device is ready for use 7 3 Establish wireless connection Conditions DMX Transmitter LumenRadio CRMS or compatible systems The X4 atom free connect is switched on At this time there is no connection to the X4 atom free connect Press the left button on the DMX transmitter The ...

Страница 12: ...atom free connect with a DMX control 7 5 Menu structure The menu structure consists of up to 5 menu levels 7 5 1 DMX start address Level 2 Level 3 Level 4 Level 5 1 511 7 5 2 DMX LED start address Level 2 Level 3 Level 4 Level 5 1 504 7 5 3 DMX channel layout GLP X4 Atom RGBW Free Connect 12 Way Channel Function Description Range DMX Comments 1 Master Intensity Master fixture intensity 0 100 0 255...

Страница 13: ...t 1 pixels 0 100 0 255 Intensity for fixture 1 only Shutter Closed 0 5 5 0 15 Random strobe Slow to Fast 6 18 5 16 47 Fade on Snap off Random Slow to Fast 19 31 48 79 Snap on Fade off Random Slow to Fast 32 43 80 111 Fade on Fade off Random Slow to Fast 44 56 112 143 Strobe with b o pause 63 77 144 199 Strobe Slow to Fast 78 94 200 239 4 Fixture 1 Shutter Shutter Open 95 100 239 255 No effect 0 2 ...

Страница 14: ...o narrow 50 to 7 degrees 0 100 0 255 No Function 0 3 0 7 Colors determined via RGBW channels 11 Fixture 1 CTO Variable CTO 10000K 2700K 3 100 8 255 GLP X4 Atom White Free Connect 12 Way Channel Function Description Range DMX Comments 1 Master Intensity Master fixture intensity 0 100 0 255 Primary Intensity Channel over all fixtures connected No Function 0 19 5 0 50 Activate Silent Mode hold value ...

Страница 15: ...3 Strobe with b o pause 63 77 144 199 Strobe Slow to Fast 78 94 200 239 4 Fixture 1 Shutter Shutter Open 95 100 239 255 5 Fixture 1 Color white Color white Intensity 0 100 0 255 6 Fixture 1 warm white warm white Intensity 0 100 0 255 7 Fixture 1 Zoom Variable wide to narrow 50 to 7 degrees 0 100 0 255 No Function 0 3 0 7 8 Fixture 1 CTO Variable CTO 10000K 2700K 3 100 8 255 9 Fixture 2 Dimmer Inte...

Страница 16: ...WM Frequency hold value for more than 1 second 39 78 5 100 200 Variabally adjust PWM frequency from 582 to 618 Hz All control hold value for more than 0 5 seconds 79 97 201 247 Copy 1 channel to all channel 2 Special Control All fixtures Reset all fixtures hold value for more than 0 5 seconds 97 5 100 248 255 Shutter Closed 0 5 5 0 15 Random strobe Slow to Fast 6 18 5 16 47 Fade on Snap off Random...

Страница 17: ...ster intensity 0 255 Fixture 1 12 Zoom 0 255 Special 0 255 White temperature 0 255 Dimmer 0 255 Shutter 0 255 White 0 255 Blue 0 255 Green 0 255 Red 0 255 Manual DMX Color wheel 0 255 Key code 0 255 Display contrast 8 8 PWM frequency adjust 582 618 Max zoom adjust 99 99 Self inspection White adjust red 99 99 White adjust green 99 99 White adjust blue 99 99 White adjust white 99 99 Offset adjust re...

Страница 18: ...OFF Set image if DMX off ON OFF Set DMX image Save image in memory Linear dimming Extr soft dimming Set dimming mode Soft dimming Master intensity 0 255 Fixture 1 12 Zoom 0 255 Special 0 255 White temperature 0 255 Dimmer 0 255 Shutter 0 255 White 0 255 Blue 0 255 Green 0 255 Red 0 255 DMX input monitor Color wheel 0 255 7 5 5 Self test program Level 2 Level 3 Level 4 Level 5 ON OFF 7 5 6 Live tim...

Страница 19: ...nnect page 19 24 7 5 7 Set DMX mode Level 2 Level 3 Level 4 Level 5 DMX RGBW mode DMX white mode DMX compressed mode 7 5 8 Reset Level 2 Level 3 Level 4 Level 5 ON OFF 7 6 Switch off device Disconnect the device from the power supply The device is switched off ...

Страница 20: ...cables can cause serious injury if they come into contact with cleaning agents Disconnect the mains plug before cleaning Observe local health and safety regulations Wait until the device has cooled down after previous operation Do not repair the device yourself Contact the customer service or retailer see chapter 11 1 Clean the surface with a dry soft and clean cloth Attention Do not use aggressiv...

Страница 21: ...x 5 51 inch Weight net 4 1 kg 9 04 lbs Compatible systems LumenRadio CRMX and compatible systems Battery Capacity 7 650 mAh Input 42 5 VAC 3 A Output 42 VDC 15 A Power supply Power input 100 240 VAC 50 60 Hz 1 2 A 120 VA Output power 42 5 VAC 2 A Antenna S W R 2 5 2400 2500 MHz Frequency range 2400 2500 MHz Impedance 50 Ohm Profit max 2 8 dBi 2400 2500 MHz Polarization Vertical Operating condition...

Страница 22: ...omponents these must be disposed of in agreement with the manufacturer according to local regulations Do not dispose of batteries and rechargeable batteries in household waste Dispose of batteries and rechargeable batteries at designated collection points This device is marked in accordance with the European Directive 2012 19 EU on waste electrical and electronic equipment Electrical and electroni...

Страница 23: ... Products Inc 1145 Arroyo Ave Unit A San Fernando CA 91340 Support Online www germanlightproducts com To use the online support it is required to go through a one time registration process Then log into the online support using your registered user account E mail support germanlightproducts com Phone 1 818 767 8899 ...

Страница 24: ...GLP German Light Products Inc 1145 Arroyo Ave Unit A San Fernando CA 91340 Phone 1 818 767 8899 E mail Support germanlightproducts com Website www germanlightproducts com ...

Отзывы: