GV-Reader 1251 and 1352 V2

The GV-Reader includes transmit-receive antenna and electronics. It has both 

Wiegand and RS-485 outputs that can be connected to any standard access 

control panel. The GV-Reader has a bi-color LED indicator, which is 

controllable by the host system and changes from red to green to indicate 

access granted. The GV-Reader also has a host-controllable buzzer. 

1

2

Packing List

GV-Reader x 1

Bag of screws x 1  

Switch Setting 

Default settings are all ON. 

ID  0 1 2 3 4 5 6 7 

SW5 OFF

OFF

OFF

OFF

ON ON ON ON 

SW6 OFF

OFF

ON ON OFF

OFF

ON ON 

SW7  OFF

ON OFF

ON OFF

ON OFF ON 

 

SW 1    Beeper Control

The default mode for the Beeper Control is the internal control. When the setting 

is “On”, the Reader is sounded after a card is read. When the setting is “Off”, the 

Beeper is controlled externally. You can use the external beeper control line to 

activate the beeper. 

SW2-SW3    Green/Red LED Control

The default mode for the Green/Red LED Control is the internal control. The 

LED is normally red. When a card is read, the LED flashes green. When the 

setting is “Off”, the Green/Red LED is controlled externally. The external control 

lines can then be used to operate the LEDs.

SW4    Master/Slave

The switch is used to select the Reader’s communication interface. When the 

setting is “On”, the Reader is controlled by Wiegand signal. When the setting is 

“Off”, the Reader is for RS-485 signal.

SW5-SW7    ID Setting

Switch 5 to switch 7 is used to set the Reader’s ID during a chain connection. 

SW8    RS-485 Terminal Resistor

When the setting is “On,” a 120-ohm resistor is connected between RS-485+ 

and RS-485-. This setting is used in the last device when multiple RS-485 

devices are connected together.

NOTE: 

After changing the dip switch settings, the unit must be reset by 

powering down then up again before the new switch setting will take effect.

Overview

1

2

3

4

5

6

7

8

ON

ECE

1

2

3

4

5

6

7

8

ON

ECE

Electric Wire

Switch

Electric Wire

GV-Reader Software CD

GV-Reader Installation Guide

3

4

Red

7.5 ~ 12 V DC

Black

GND

Green

Wiegand Data0

White

Wiegand Data1

Blue

RS-485 +

Light Blue

RS- 485 -

Yellow

Beeper

Orange

Green LED

Light Red

Red  LED

Содержание GV-Reader 1251

Страница 1: ...internal control The LED is normally red When a card is read the LED flashes green When the setting is Off the Green Red LED is controlled externally The external control lines can then be used to operate the LEDs SW4 Master Slave The switch is used to select the Reader s communication interface When the setting is On the Reader is controlled by Wiegand signal When the setting is Off the Reader is...

Страница 2: ...o connect the GV Reader to third party access controllers and GV System After you wire the connection between the GV Reader and the access controller ensure the related switch setting on the GV Reader is configured correctly ECE SW4 must be turned ON GV AS Controller 1 2 3 4 5 6 7 8 ON ECE Switch Setting for RS 485 Connection SW4 must be turned OFF Multiple GV Readers can be connected to the GV AS...

Страница 3: ...or the reader under Function Click Submit Light blue Connecting to GV System and Third Party Access Controllers GV System GV COM GV Hub GV NET IO Card V3 1 Access Controller third party power supply 7 5 12 V Red Black Blue USB Green White GV Reader is also compatible with third party access controllers With its compatibility you can also add a GV System to this connection to empower your managemen...

Страница 4: ...5 mm with enclosure 35 D mm 3 x 4 5 x 0 6 in with enclosure 1 38 D in Weight 150 g 0 33 lb Ingress Protection IP54 GV Reader 1251 V1 GV Reader 1352 V2 Operation Temperature 13 56 MHz for ISO14443A Mifare Class The number of GV Readers supported by GV AS Controllers GV AS Controller Model GV Reader Interface Wiegand RS 485 1 1 GV AS100 1 Not supported GV AS110 120 2 4 GV AS100 110 120 with GV ASBox...

Отзывы: