EX11x/21x Series
Quick Start Guide
253.872.0284 seametrics.com
Components
Sensor with Electronics or
Blind Housing, depending on
options ordered.
Recommended Tools
Recommended:
• Pipe drill or hole cutting saw
• 5/32” allen wrench
• Crescent Wrench
Optional:
• Channel locks
Warnings
•
This meter is sensitive to heat. Do not weld or flame cut within
10’ of meter. Heat will damage electronics. (Heat will void
warranty.)
•
Never attempt to remove a flow sensor when there is pressure
in the pipe unless it is specifically designed for hot tap
installation and removal. Loosen the compression nut slowly
to release any trapped pressure. If fluid sprays out when
removing the sensor, stop turning and depressurize the pipe.
Failure to do so could result in the sensor being thrown from
the pipe, resulting in damage or serious injury.
• Improper sealing of cables or cable glands will void warranty.
• Not recommended for installation downstream of a boiler
feedwater pump where installation fault may expose the
flow sensor to boiler pressure and temperature. Maximum
recommended temperature is 130°F (Plastic), 200°F (Metal).
• The EX11x/21x has a strong start and run current. When
using solar panels and VRSLA batteries as a power source, use
caution to insure the EX-Series sensor has the -50 Low-power
Option and that all Seametrics products on the power circuit
receive sufficient voltage and current under all conditions.
Failure to do so will lead to unreliable operation and possible
damage to the unit(s).
Refer to instruction manual for further details.
Seametrics supplied saddle or user
supplied saddle or weldolet with
1.5” female pipe threads