background image

 

27250006  REV 06-06-12 

 
 

Marschalk 

Model # 94000 

12-volt  DC Portable oil-less 

Air  Compressor 

Operation Manual 

 
 
 

 

Содержание Marschalk 94000

Страница 1: ...27250006 REV 06 06 12 Marschalk Model 94000 12 volt DC Portable oil less Air Compressor Operation Manual...

Страница 2: ...System Components 5 Chapter 2 System Installation 6 Chapter 3 System Operation 7 Low Flow Purging and Sampling 8 Chapter 4 System Maintenance 9 Chapter 5 System Specifications 10 Chapter 6 System Sche...

Страница 3: ...proceed until you read and thoroughly understand the WARNING message A raised hand icon indicates CAUTION information that relates to a situation or condition that could lead to equipment malfunction...

Страница 4: ...ibration will occur which can cause fittings to come loose Inspect and tighten as necessary as part of a normal maintenance program and prior to each use of the unit Never operate a damaged unit Befor...

Страница 5: ...standards for quality reliability and portability in a compressed air package for groundwater monitoring It is one of the very few packages available today that is designed and built specifically to...

Страница 6: ...e fittings including a male plug quick connect fitting on the tank discharge for connection of the controller air hose which is also included A Gast 1 6th horsepower heavy duty motor mounted oil less...

Страница 7: ...VE BLACK NEGATIVE 5 This is a standard connection for 12 volt D C power and is found on virtually every vehicle battery 6 Close the ball valve located on the discharge side of the air storage tank han...

Страница 8: ...dicated on the pressure switch label the compressor will shut off when tank pressure reaches 90 psig and will come back on when tank pressure drops to about 70 psig Connect the quick connect end of th...

Страница 9: ...of each pump cycle For 100 mls minute flow rate use 1 x 1 minute pump cycle If Low Submergence operation of the pump controller is necessary longer pump cycles become even more important as the vacuu...

Страница 10: ...o drain the tank simply open drain petcock on the bottom of the air tank for a few seconds then close the petcock Periodically check for loose hardware and tighten as necessary This includes all nuts...

Страница 11: ...22 Amps Starting Amperage 160 Amps Storage Capacity 3 Gallons Max Pressure 100 PSI SCFM Atmosphere 1 25 SCFM 50 PSI 0 65 SCFM 90 PSI 0 40 Case Height 12 in Length 24 in Width 20 in Tank Height 8 1 2 i...

Страница 12: ...11 Chapter 6 System Schematic Check Valve SS Hose Air Filter Handle 12vdc Motor Pressure Switch Air Out Off Auto Air Tank Compressor Head Pressure Relief Tank Drain Gauge Valve Starter Solenoid...

Страница 13: ...tor 17250017 Air Tank 17250018 Pressure Gauge 17250019 Starter Solenoid 17250020 Pressure Switch 17250021 Ball Valve 17250022 Check Valve 17250024 Rubber Feet 17250026 Stainless Steel Hose 27250003 We...

Страница 14: ...prior to return of any equipment to our facilities please call our 800 number for appropriate location An RMA will be issued upon receipt of your request to return equipment which should include reaso...

Страница 15: ...Geotech Environmental Equipment Inc 8035 East 40th Avenue Denver Colorado 80207 303 320 4764 800 833 7958 FAX 303 322 7242 email sales geotechenv com website www geotechenv com...