7
Reverse Coil Method
When lowering the pump into the well, it is important to reverse the natural bend of the
coiled tubing so that the tubing will straighten out as it is lowered (see figure 2-1). As the
pump and tubing are lowered into the well, the direction of the bend should be reversed
from the direction in which it is coiled. If the tubing is allowed to uncoil naturally and the
natural bend not interrupted, the tubing will continue its coil into the well. Using the reverse
coil method will avoid difficulty in lowering the pump into the well, especially when the well
is not vertical, or has come out of alignment for any reason.
Optional Drop Tube Intake Assembly
If a Drop Tube Intake Assembly is employed, a third tubing line is necessary to connect
from the bottom of the bladder pump to the top of the drop tube intake.
For deployment of optional Drop Tube Intake Assembly, attach desired length of drop tube
between the intake
’s hose barb and hose barb on bottom of pump. For added security, a
safety cable may be installed to support the drop tube intake to the bottom of pump.
Send the drop tube intake down the well followed by the drop tube tubing, then the pump,
and finally the air and fluid discharge lines.
Figure 2-1:
Reverse Coil Method
Содержание 1.66x18
Страница 1: ...Rev 4 15 2020 Part 11150324 PFAS Free Portable Bladder Pump Installation and Operation Manual...
Страница 2: ......
Страница 13: ...11 Figure 3 1 Tank Volume vs BP Consumption...
Страница 26: ...24 Section 7 Replacement Parts List 1 66 Bladder Pump Components 18 model shown...
Страница 28: ...26 850 Bladder Pump Components...
Страница 30: ...28 675 Bladder Pump Components...
Страница 32: ...30 Notes...