Check & Adjust
4.3 Combined Adjustment (l, t, i, c and Aim360)
Description
The combined adjustment procedure determines the following instrument
errors in one process:
Combined
adjustment
procedure
step-by-step
The following table explains the most common settings.
l, t
Compensator longitudinal and transversal index errors
i
Vertical index error, related to the standing axis
c
Horizontal collimation error, also called line of sight error
Aim360 Hz
Aim360 zero point error for horizontal angle option
Aim360 V
Aim360 zero point error for vertical angle option
Step
Description
1.
Main Menu: Tools...
\
Check & Adjust...
2.
TOOLS Check & Adjust Menu
Select the option: Combined (l,t,i,c,Aim)
3.
TOOLS Combined I
<Aim Adjust: On> Includes the determination of the Aim360 Hz
and V adjustment errors.
It is recommended to use a clean GeoMax circular prism as
target. Do not use a 360° prism.