6.2
Menu Set 1
007606_001
Menu Set 1
In the Menu Set 1, you can select the following parameters:
•
Head Speed settings
•
H.I.Alert - On/Off
•
Automatic/Manual Modes
•
Sensitivity settings
•
Beam Masking
☞
To exit the menu, highlight and select the EXIT
icon. OR: Wait for 8 seconds and the menu is
exited automatically.
☞
To display the Menu Set 2, highlight and select the
MENU 2 icon.
007608_001
Head Speed Settings
You can select three head speed settings:
•
5 rps
•
10 rps
007609_001
H.I.Alert Settings
You can choose to enable or disable the H.I.Alert function:
•
On
•
Off
When enabled, the H.I.Alert function turns on automatically
every time the Zone60 DG is turned on. The function becomes
active 30 seconds after turning on the Zone60 DG.
How does the H.I.Alert function work?
The Height of Instrument (H.I.) or Elevation Alert function prevents incorrect work caused by
movement or settling of the tripod that would cause the laser to level at a lower height.
30 seconds after the Zone60 DG has levelled and the head of the laser starts rotating, the
H.I.Alert function becomes active.
007610_001
H.I.Alert screen
The H.I.Alert function monitors the movement of the laser; if dis-
turbed, the H.I.Alert screen flashes and the Zone60 DG beeps
rapidly.
To stop the alert, turn the Zone60 DG off and on again. Check
the height of the laser before beginning to work again.
Overview
Head Speed Settings
H.I.Alert - On/Off
34
Zone60 DG Menu