Geo-Loop 40-500 Скачать руководство пользователя страница 1

40-500 Gas 

July 27, 2018

 

 

Grout Pump Automatic & Manual Troubleshooting  

40-500 Gas Wiring Diagram 

 

Turn engine off and relieve hydraulic pressure and grout pressure before troubleshooting.  
 
Note: 

Typically there is a wiring diagram on the gray Geo-Loop electric box inside the cover. If not we 
can e-mail you a copy to help troubleshoot your problem. 
 
 
 
These are wires pertaining to operation of grout pump manual and auto switches.  
 
First let’s talk through the circuit that typically will fix the problem, if the grout pump electric 
troubleshooting guide will not fix the problem.  
 
Starting with 12 volt DC from the grout pump fuse, red 14 gauge wire power supply to both 
toggle switches. 

(1) 

Grout pump manual switch has jumper wire from center terminal over to 

grout pump auto switch (either terminal).   
 
Grout pump auto toggle switch (black wire, load side of switch) powers the common terminal 
on the ratchet relay 

(3) 

located in the gray Geo-Loop electric box and two blue wires 

(5)

 going 

to the micro switches on the grout cylinders.  
 

 

(1)

 Red 14 gauge wire 

power supply from 
grout fuse  

(5)

 From grout pump auto 

single pole single throw 
toggle switch load side 
Note: old style micro 
switches use a black wire 

(see 8B diagram on page 2)

.  

 

(3)

 Ratchet Relay Com 

Red wire – grout pump 
15 amp fuse  

Keyed power 10 amp fuse 

Oil cooler fan 15 amp fuse 

Power in from battery 30 amp fuse 