Algebraic sign

  

Status symbols

= Initialising
Inclination adjustment
Inclination adjustment finished,
power saving mode

    

T = Kick guard active (see 

3.3

)

T = Blinks after jerky movement,

laser beam off  

    

Power supply indicator

    

Laser beam symbols:

Laser blinks when levelling
Laser off when levelling
Laser + rotor off with FB-10

 

Percent sign (see 

3.5

)

Inclination value, x/y axis resp. OFF
Rotor speed (8 = 800 rpm)

< 1/4  < 1/2  < 3/4  >3/4

Keep the button pressed until the adjustment menu is shown.

5

=

factory defaults

factory defaults

actory defaults

on. When setting the inclination, + or - can be selected and 
then inverted.

=

off (factory default)

Please note: 

Setting only possible in a range of ± 5 %.

   

   

3.10 Laser Power

    

The laser power can be regulated in 5 steps from approx. 0.5 mW 
to < 2.6 mW. 
Up to a range of approx. 200 m step 2 = < 1 mW is recommended.

   

  

 

=  <  2.6 mW (

)

  

3.11 Operation Mode Laser Beam

    

Laser beam and laser beam symbol at the operating mode 

=

display blink when levelling (

).

    

=

Laser beam is off when levelling.
However the symbol blinks at the operating mode display.

   

3.12 F

    

=

All set to factory defaults.

   

3.13 Service/Workshop Notice

First off all a phone no. for service/help appears. Then authorized 
personnel can put in a numerical code to come to the adjustment 
mode.

Select Letter

The selected letter blinks.

Change Settings

Back to Operating Display

or

or

Menu

OK

=  Select Indication of Factory Defaults

6. Locking Automatic 

(see 

19.

)

   

in the Y axis in combination with the locking receiver FE-53. Laser and receiver 
correspond via radio circuit.
By pressing the button of laser or receiver the laser starts to search for the receiver. 
As soon as the rotating laser beam hits the receiver, it is directed to the center and 
fixed there.

6.1 Operation

  

Set-up laser and receiver over the line axis, switch on 
both, switch off Y axis and set the rotor speed to 800 
rpm. As soon as the radio control is connected, the 
system starts to operate.

On the laser display an alternating direction arrow 
appears and on the receiver the LEDs are blinking 
alternately. 
Accuracy: to +/- 0.5 mm/100 m.

The FE-53 can be mounted either on the left or on the right side of the laser. 
Because of reasons of functionality, the keyboards of both devices must be on the 
same side. 

Scan mode

   

Radio control:
    connected
    connected and laser reception
    disconnected

  

Direction arrow
Centre indicator
Rotor speed 

8

 = 800 rpm

6.2 Display Locking Automatic (Horizontal Set-Up)

6.3 Scan Mode

    

It can be started either at receiver or at laser. After its activation the laser scans and 
finds the receiver automatically.

Start scan at laser:

Menu

OK

3 x

=

 

or

=

Scan starts.
The       indicates the control direction on the display.

S

 blinks

 

Note:

A radio communication with the FE-53 is provided, indicated by the 
symbol "   " on the LCD display (see 1.9).

8. 

      

8.1 Horizontal Light Plane (

)

    

Adjustment Checking

Set-up the laser upright and mark laser beam in the height of the required 
measuring distance. Turn laser device on the tripod by 180°, mark once again. If 
the adjustment is perfect, the first mark does not deviate from the second one. Turn 
device by 90°, repeat this process.

Vertical Set-Up

8.2 Horizontal Plumb Beam (

/Pipe Laying)

Horizontal Set-Up

8.3 Adjustment

   

If the adjustment is incorrect, please contact your specialist dealer.

The laser can be adjusted in the field without having to open the device. For safety 
reasons, however, adjustment should only be carried out by authorized 
personnel. See the special adjustment instructions in this regard.

Pressing the arrow buttons briefly changes the inclination value by 0.001 %. 
The value is changed with increasing speed if the button is kept pressed.

+

=   2.4   X Inclination Setting to Zero

The inclination value is set to 0.000 % by pressing the two arrow buttons at 
the same time.

Y Inclination Setting

(Vertical set-up)

or

or

Direction Setting

(Horizontal set-up)

Y   Inclination Setting to Zero or
Direction Centering

+

=  2.7

Vertical set-up:

Horizontal set-up: Device is automatically centred in middle position.

The inclination value is set to 0.000 % by pressing the 
arrow buttons at the same time.

2.8  Quick Setting

In addition to the respective arrow button also press the ON/OFF button.

After setting one of the two arrow buttons the laser beam symbol changes to an 
arrow. It indicates the direction of movement and the current position. When end 
position is reached, the laser beam and limitation symbol blink. The setting must 
then be moved back within 2.5 minutes. If this is not done, the laser is switched off 
automatically.

Grade swap: minus or plus

(to activate see 

3.9

)

or

3. Device Settings

=  2.6

=  2.9

3.1 Switch ON/OFF Automatic Levelling

   

:

=

These are the factory defaults. They are always activated when 
switching-on the laser.

=

utomatic self-levelling cutted out in X and Y axis.

:

=

utomatic self-levelling swiched on in X axis.

These are the factory defaults. They are always activated when 
switching-on the laser.

= Automatic self-levelling swiched off.

On the display appears 

OFF %

.

= Settings unlocked (

= I

= Inclination and direction setting locked.

Now direction control is not possible.

Vertical Set-Up

Horizontal Set-Up

3.2 Sensitivity Setting (Wind/Vibration) 

The self-levelling function corrects even the smallest deviation. 
Additionally the laser beam and the laser beam symbol at the operating 
mode display blink when the limit values of step 1 to 3 are exceeded,
i. e. by influence of wind and/or vibration. 

  

1 =   0.005 % no effect
2 =   0.010 % weak effect (

)

3 =   0.015 % stronger effect

   

3.3 Kick Guard (Automatic Laser Beam Cut-Out)

= Kick guard switched on. It is only active after 30 sec. Then a 

appears

in front of the battery symbol at the operating mode display
This means the laser is switched off automatically as a precautionary 
measure in the event of a jerky movement (bump). The 

T

 then begins to 

blink. The laser must be switched on again by pressing briefly the ON-
button and the positioning must be checked and corrected if necessary.

   

= F

: Kick guard switched off.

  

   

3.4 Inclination value display in % or ‰

    

Select between % or ‰ indicator.

   

=

)

nclination setting locked.

Automatic levelling switched on.

A
On the display appears behind the 

X

 and 

Y

 

OFF

.

Now the X and Y axes can be selected and set by the arrow buttons.

A

   

factory defaults

actory defaults

When the automatic is switched off in X and Y axes, it is not possible to 
activate the kick guard.

factory defaults

3.5 Lock Function only when Setting-up Horizontally

factory defaults .

  

   

    

 

.

3.6

    

   

=

   

=

3.9

    

Radio Control On/Off

Is required for the operation with the remote control FB-10 or locking 
receiver FE-53/-61.

off (energy-saving mode)

on (

)

  

3.7 Laser Beam Modulation Mode

      

=

Standard modulation for FE-61 (

)

   

=

db

 

 

 

 

=

Modulation off

    

=

Flickering for LE-7x stationary beam

3.8 Monitoring of Locking Automatic 

When using the locking receivers FE-53/-61 the automatic locking can be 
monitored. The laser beam switches off when the laser or radio 
contact is interruped for more than 3 min.
It can be switched on again by briefly pressing the laser ON button.

   

=

off (

)

   

=

on

factory defaults

factory defaults

factory defaults

Grade swap

It is possible to transfer the inclination i. e. of a roof profile from
one side to the other.

7. Inclination Measurement Parallel to Ground

     

Even if the inclination is unknown, it can simply be adapted to the ground.

9 - 21

10 - 21

8 - 21

11 - 21

12 - 21

7 - 21

Automatik-Kanalbau-Laser 
KL-80/-81

=   2.1  ON/OFF Button

The device is switched on by pressing this button. The device and company data 
are then shown, followed by the operating display with the last settings without 
button lock. The device is then levelled and referenced on the zero point 
automatically. After the levelling phase the laser beam and laser beam symbol stop 
blinking. If this does not happen, the device must be moved into the levelling range 
by tilting it forwards. The display illumination switches off after approx. 30 seconds 
automatically. The illumination is switched on again by pressing the ON/OFF 
button shortly.
To switch off the device, press the ON/OFF button until “Auf Wiedersehen !” 
appears.

 

=  2.2  

When setting-up vertically, the X inclination setting, the y inclination setting and the 
rotor setting, when setting-up horizontally the lock symbol and the rotor speed are 
selected and released one after the other by pressing the MENU/OK button.
The respectively activated point blinks.
If, after setting the speed, the button is pressed again or a time of about 25 
seconds passes, the adjustment guard is reactivated automatically. This means: 
the arrow buttons do not work.

Lock-, Rotor Speed- and X Inclination 
Setting

or

=  2.3

Menu

OK

Arrow Buttons - Release
Select - Set - Confirm

Date  12/2015                                                                                                                               Subjct to change

4 - 21

5 - 21

6 - 21

1.8  Bubble Tube

 (

Set-up help).

Universal-Laser UL-89L

FE 53

-

FB-10

L -72

E

one

 for

 all

   .

 .

.

FE-61

=  2.5

Check or Change Device Settings

or automatically after 25 seconds.

6

laser beam

FE-53

Y axis

Horizontal- Set-Up

=

=

=

+

+

+

2.

Buttons

1.15 Antenna Remote Control 

(see 

21.

)

1.  

 

Description

1.1  Function

    

The automatic universal laser UL-89L is a multifunction laser with 
inclination setting for horizontal and vertical use capable of 
electronic self-levelling over three axes. It emits a laser 
beam, which turns into a light plane as it rotates. 
Another laser beam is available exactly square to it.
The operation is made at the laser or optionally with the
wireless control FB-10. The rotating laser beam in the Y axis is locked 
by the locking receiver FE-53 and the plumb beam in the Y and X axes 
by the FE-61.

1.7  Bulging 
GroundArea, niro St.

   

Protects against damages of 
coat and guarantees a secure 
stand. 
Central fastening thread 5/8“.

Identification

m

Plumb-Bea

Plumb-Up-Beam

1.12 Rotor Head

  

Rotor speed adjustable from 200 - 1000 rpm.

1.14 Handle

  

For easy handling, safe transport and simple set-up.

1.2  Inclination Symbol

 

Enables clear inclination assignment. 
The +/- and X/Y symbols indicate the inclination. The + ranges are 
light and the - ranges dark.
The symbol also shows the inclination and its change relative to 
the centre axis.

1.6 Laser Warning Sign

 

Laser

 

class 3R, P < 5 mW

1.4 Keyboard

  

Clear layout. User-friendly, self-explanatory keys.

1.5 Robust Light Metal Housing

  

Plastic-coated, swept with nitrogen, 100 % watertight.

1.3 Charging Socket

   

Behind the dust guard cap.

1.10 Optical sight

   

for quick alignment of the inclination axis.

1.13  Manual Rotor Setting

  

Pressed in: rotor motor cut out
Extracted:

rotor motor cut in again

By turning: setting of the desired position

1.11 Box Level 

in rotor head for plumb-down function.

Fixing Foot

Sliding
Foot

Horizontal Set-Up

Vertical Set-Up

Operating Instructions

Congratulations on your new GEO laser

  

This operating instructions contain enclosed in addition to 
information on how to use the laser 

important safety 

information

.

First read the safety instructions on the
supplement page 

 and then the operating 

instructions carefully before using the laser.

 

  

Please note:

1 - 3

Uncompromising versatility

   + much more

Two-Axis Inclination Laser

Levelling Laser

Aligning Laser

   Plumb Laser

   

automatically

   

lock alignment

   

find alignment

   

search for alignment

1.9  LCD-Display, Horizontal Set-up (Pipe Laying)

Lock symbol open / closed
Algebraic sign
Inclination value
Percent sign
Status symbols:

Initialising
Inclination adjustment 
Inclination adjustment finished,
power saving mode

    

T = Kick guard active (see 

3.3

)

T = Blinks after jerky movement,

laser beam off   

    

Power supply indicator 

  

Scan locking automatic

   

Radio control with FE-53/-61/FB-10:
    connected
    connected and laser reception
    disconnected

  

Direction limitation
Centring indicator
Direction arrow
Centre indicator
Laser beam symbol
Laser beam and rotor off by remote 
control
Rotor speed (8 = 800 rpm)

< 1/4  < 1/2  < 3/4  >3/4

1.16 LCD-Display, Vertical Set-up (Surface Construction)

A

=

E

=

T

=

P

=

V

= Lock

K

M

=

R

=

U

=

L

=

B

=

W

=

S

=

Automatic cut out
Sensivity
Kick guard
Percent / Per mil

Radio control
Laser beam modulation
Direction automatic
Grade swap
Laser power
Duty type - laser beam
Factory defaults
Service/workshop information

Factory defaults

on/off

Laser blinks when levelling
Laser off when levelling

off/on
off/on

monitored

S

= standard for FE-61

P

= db

-

= off

F

= Flicker for LE-7x standing

on/off

                           laser beam

off/on

on/off

=
=

  

1 - 5

 :

  

I

= X axis

+

= X axis + Y axis

  

%

 or 

1 - 3

 = approx. 5 - 15 mm/100m

1 - 2 = 

 2

3 - 5 = 

 3R

Laser class
Laser class

Display Device Settings

1   2   3            

4      

  

5   6

  

7   8

  

9  10

  

11    

  

12

  

13

Although the laser is adjusted precisely by the manufacturer, jolts and strong 
vibrations can lead to maladjustment. The laser should therefore be checked 
before use:

   

1. Select a measuring area of approx. 40 m that is as horizontal as possible and

set up the laser with the counter at 0.000%.

  

2. Set up two control points, one directly in front of the laser and the other in a 

distance of approx. 40 m, and measure the distance to the centre of the laser 
beam 

"a"

 and 

"b"

.

  

3. Set up the laser behind the second measuring point and repeat the measuring 

process in reverse direction, this means measure 

"A"

 and 

"B"

.

  

4. If the adjustment is correct,   A - a = B - b. This means, the laser beam of the first

installation is parallel to the second one.

Error-free: A - a = B - b

1st build

A

a

Hz

40 m

B

b

2nd build

5.3 Height Transfer

5.2 Axis Transfer by Bearing over the Plumb Line

5.1 Axis Transfer with the Alignment Line

5. Transfer Possibilities

Alignment line

2nd plumb

Aim point

Datum

1st plumb

Aim point

plumb line

2.

3.

1.

Set up laser over the axis.

2.

Look over the plumb line and align it to the alignment rod. 

3.

Look over the plumb line to the laser beam and align the laser in the 
direction.

Measuring rod

Height point

Level device

6

5

A

B

Rod reading A

- Rod reading B
+ 65 mm
+ 1/2 
-----------------------
= Pipe invert 

Ø

4. Pipe Laying Made Easy

Mount device over the point of reference in such a way that the bubble tube is 
levelled in. Adjust the inclination and align the laser beam to the point of aim. After 
that join pipe after pipe and align each end to the target.

4.1. Set-up

The laser can be set up centrically or at a constant distance above the pipe 
invert. Suitable legs, tripods and fastening systems are available for this. 

  

Note:

If the diameter indicated on the legs does not correspond with the pipe 
diameter, the target has to be set up directly in front of the laser and must 
be adjusted to the correct height ignoring the diameter marking.

L

a

s

e

r

C

o

n

s

tr

u

c

ti

o

n

H

e

ig

h

t

Reference
Point

X

  n

ln

i

x

I

ci

at

o

A

is

Aiming Point

L

a

s

e

r

C

o

n

s

tr

u

c

ti

o

n

H

e

ig

h

t

Scanning locking receiver
Direction arrow
alternately 

OFF

 resp.

inclination value

  

  
Radio control:
    connected
    connected and laser reception
    disconnected

7.1. Operating Instructions

    

Mount laser above the reference point and align the Y inclination axis to the 
aiming point. Adjust banking in the X axis.
Measure laser construction height with the locking receiver FE-53 and a 
levelling rod. Transfer this height to the aiming point.
Release the automatic scan with the A button of the receiver.
The light plane is now automatically directed within typically 2 min./max. 5 min. 
to the centre of the receiver and locked there.
The LEDs at the FE-53 are blinking alternately. On the display 

OFF

 and the 

approx. inclination value are shown alternately.
Now the FE-53 can be removed abruptly off the laser light plane and switched 
off. After approx. 30 seconds the exact inclination value is shown on the 
display and automatically locked. The % symbol is blinking.

   

Alternatively the FE-53 can be mounted permanently to realize a long-term 
fixing of the laser light plane.

       

Please note:

Never operate the remote control or inclination setting at the 
laser in this mode because by this the laser light plane is moved. 
Precondition is an established radio link to the FE-53, indicated 
by the symbol on the LCD display.

7.2 Display Inclination Measurement (Vertical Laser Set-up)

Отзывы: