
8
CONTROL FUNCTIONS
CONTROL PANEL FEATURES GM9000iE
①
120-Volt, 20-Amp Duplex Outlet (NEMA 5-20R):
The outlet is capable of carrying a maximum of 20
amps.
②
USB Duplex:
5V DC that come in 1 amps and 2.1
amps.
③
Reset:
If the inverter is overloaded, the reset
breaker will trip. The engine will continue to run, but
there will be no output from the inverter. Unplug the
devices and reduce the load. Push in the reset
breaker to reset it.
④
Low Idle:
When turned to the ON position, the
engine will sense the load needed and run at a slower
RPM to save fuel.
⑤
Ground Terminal:
The ground terminal is used to
externally ground the inverter.
⑥
Fuel Switch:
Open the fuel.
⑦
AC Breaker:
If the inverter is overloaded, the reset
breaker will trip to block current.
⑧
Main Switch:
Manage battery power and
shutdown.
⑨
120/240-Volt, 30-Amp Outlet
:
The outlet
(L5-30)
is capable of carrying a maximum of 30 amps.
⑩
CO Alarm:
Shuts down the engine in the event of
CO buildup.
⑪
One Push Start:
Press this button, the engine can
start and stop.
⑫
Voltage Selector:
Switch between 120V and 240V
voltage as required
.
⑬
120/240 Volt AC, 50 Amp NEMA 14-50R
Receptacle:
Receptacle can supply a maximum of
50 Amps.
⑭
Parallel Connectors:
To increase AC power output,
the connector sockets are used to connect the two
same type generator with special paralleling cords.
The connector sockets is only used to the
communication between the inverters, they can not
used for AC power output. The special paralleling
cords shall be purchase separately, and they shall be
approved by certification body.
11
10
12
13
14
Содержание GM9000iE
Страница 7: ...6 SAFETY INSTRUCTIONS SAFETY LABELS AND DECALS...
Страница 27: ...26 TROUBLESHOOTING...
Страница 28: ...27 TROUBLESHOOTING...
Страница 30: ...29 CIRCUIT DIAGRAM GM9000iE SCHEMATICS...
Страница 31: ...30 GM9000iED GM9000iEDC SCHEMATICS CIRCUIT DIAGRAM...
Страница 32: ...31 R CHOOSING A GENERATOR 1...