GENMAX GM9000iE Скачать руководство пользователя страница 20

19

SERVICE AND MAINTENANCE

Good maintenance and service is the best guarantee for safe, economical and zero-failure operation. It also 

contributes to environmental protection.

In order to keep the generator in good condition, you must inspect and maintain it regularly. The maintenance 

schedule is as follows:

Maintenance cycle

Item

Each

First in 1 month 

or 20 hours

Then every three 

months or every 

50 hours

100 hours per 

year or use

Engine

 

oil

Gearbox gear 
Oil (if any)

Air cleaner 
element 

Settling cup (if any)

Spark plug

Spark eliminator

Idle speed 
(if any)**

Valve clearance**

Fuel tank and 
fuel filter***

Fuel line

Cylinder head,
piston

Displacement < 225cc, every 125 hours; displacement 
capacity ≥ 225cc, every 250 hours.

Check

-

fill

Replace

Replace

Check

 

oil

Inspection

Clean

Replace

Clean

Clean-adjust

Clean

Check-adjust

Check-adjust

Clean

Inspection

Remove 
carbon 
deposit**

Every two yeara (Please replace if ecessary)

√*

*    hese

T

 

items

 

shall

 

be

 

replaced

 

if

 

necessary;

**  he

T

se

 

items

 

shall

 

be

 

maintained

 

by

 

the

 

dealer

 

authorized

 

by

 

the

 

Company

,

 

unless

 

the 

user

 

has

 

proper

 

tools

 

and

 

maintenance

 

ability

 

ATTENTION

• 

 If it often works under high temperature or high load, oil shall be changed every 25 hours;

• 

 If it often works in dusty or harsh environment, air cleaner element shall be cleaned every 10 hours. If 

necessary, the air cleaner element shall be replaced every 25 hours;

• 

 It shall be maintained on spot-inspection cycle and time, whichever is earlier;

•  

If maintenance cycle time has elapsed, perform the maintenance as soon as possible as per the table 

above.

Содержание GM9000iE

Страница 1: ...9000iEDC Portable Inverter Generator 7600 GAS 7200 LPG Running Watts 9000 GAS 8550 LPG Peak Watts This manual contains important information regarding safety Operation maintenance and storage of this...

Страница 2: ...manual are intended as representative reference views only Moreover because of our continuous product improvement policy we may modify information illustrations and or speci cations to explain and or...

Страница 3: ...ery service i e assembly oil or lubricants and adjustment E Items or service that are normally required to maintain the product i e lubricants and lters F Warrantor will not pay for repairs or adjustm...

Страница 4: ...GENERATOR 16 USING THE GENERATOR 17 1 Service environment of the generator 17 2 Generator wiring 17 3 Generator grounding 18 SERVICE AND MAINTENANCE 19 1 Spark plug inspection 20 2 Adjustment of the c...

Страница 5: ...rs where the neutral is oating the operator s manual shall include the following wording or equivalent The portable generator stator winding is isolated from the frame and from the AC receptacle groun...

Страница 6: ...and familiarize yourself with the safe operation procedures of the generator Please do not use indoors Please do not use in humid environment Please do not connect it to household appliances directly...

Страница 7: ...6 SAFETY INSTRUCTIONS SAFETY LABELS AND DECALS...

Страница 8: ...7 NAMES OF COMPONENTS Drag rod Fuel tank Control panel Left enclosure Start handle Muf er Wheel Right enclosure LPG Port GM9000iED GM9000iEDC only...

Страница 9: ...ter is overloaded the reset breaker will trip to block current Main Switch Manage battery power and shutdown 120 240 Volt 30 Amp Outlet The outlet L5 30 is capable of carrying a maximum of 30 amps CO...

Страница 10: ...et breaker will trip to block current Main Switch Manage battery power and shutdown 120 240 Volt 30 Amp Outlet The outlet L5 30 is capable of carrying a maximum of 30 amps CO Alarm Shuts down the engi...

Страница 11: ...time of the generator The two factors and are displayed alternately every 8 seconds VOLTAGE Voltage display 120V and 240V switch every 16 seconds FREQUENCY Frequency display LOAD Load power display PO...

Страница 12: ...soline must be used as leaded gasoline can seriously damage internal parts of the generator Remove fuel tank cap and add gasoline to red horizontal indicating line oil level Fuel tank capacity 6 9gal...

Страница 13: ...repair carefully Tip The condition of the generator shall be inspected before using every time Pre operation inspection Fuel Check fuel level in fuel tank of the generator and fuel it if necessary Oil...

Страница 14: ...trodes of the battery 2 Press the LOW IDLE switch to OFF 4 Turn the fuel switch clockwise to ON 3 Select Boot Mode a Hand Starting Pull the starting handle to start the generator b One Button to Start...

Страница 15: ...b LPG 1 Connect the LPG hose to the LPG tank 2 Tighten the other end of the LPG hose to the generator intake 3 Turn the fuel source switch to LPG 3 1 2 GM9000iED GM9000iEDC Startup Procedure Remove th...

Страница 16: ...ote control to start the generator 6 a b c Plug in after started 7 Remote Control Pairing 1 Long press the start button for more than 5 seconds until the button red indicator is on 2 Press any key on...

Страница 17: ...d 1 Select Stop Mode a One Button to Start Press the one click start button to turn off the generator b Remote Start Press the STOP button on the remote control to turn off the generator 2 a b Press t...

Страница 18: ...e the power of generator by about 1 5 Every 300 m rising of ASL will reduce the power the generator by about 4 5 Generator wiring 2 When the generator is connected to household power source as a backu...

Страница 19: ...t up Switch on electrical equipment Tip Before increasing engine speed energy saving switch must be switched to OFF If the generator set supplies power to multi loads or electrical equipment start fro...

Страница 20: ...lacement capacity 225cc every 250 hours Check ll Replace Replace Check oil Inspection Clean Replace Clean Clean adjust Clean Check adjust Check adjust Clean Inspection Remove carbon deposit Every two...

Страница 21: ...ciousness and even death Spark plug inspection 1 Spark plug is an important part of the generator which must be inspected regularly Remove the left panel cover and remove the high voltage pack 1 Inser...

Страница 22: ...ealer with professional knowledge professional data and equipment to ensure that the adjustment is proper Replacement of oil 3 WARNING Do not drain the oil immediately after turning off the generator...

Страница 23: ...plate of air cleaner 1 Clean foam cleaner element with cleaning solvent and blow it dry Put a few drops of oil on the lter element 2 ATTENTION Be sure not to twist the foam cleaner element forcibly t...

Страница 24: ...tank of the generator in a place where smoking or with ame 1 Remove fuel tank cap and fuel tank lter screen 2 Clean fuel tank lter screen with gasoline 3 Wipe lter screen dry and put it back into fuel...

Страница 25: ...y electrical equipment Running time of the engine depends on remaining fuel in the fuel tank Open generator left exterior cover and enter carburetor Locate the clear plastic hose from the carburetor a...

Страница 26: ...the generator set in a clean and dry area 10 Generator transport 2 When the generator set is transported it shall be ensured that there is no fuel spilling Do not ll excessive fuel into fuel tank Do...

Страница 27: ...26 TROUBLESHOOTING...

Страница 28: ...27 TROUBLESHOOTING...

Страница 29: ...ltage V Rated Frequency Hz Rated Power Factor Phase Number 62 7 6 9 0 120 240 60 1 Single phase Run Time 25 h 14 Overall Dimension in Net Weight lb 30 9x22 6x29 3 233 7 GM9000iED GM9000iEDC OHV 3600 6...

Страница 30: ...29 CIRCUIT DIAGRAM GM9000iE SCHEMATICS...

Страница 31: ...30 GM9000iED GM9000iEDC SCHEMATICS CIRCUIT DIAGRAM...

Страница 32: ...31 R CHOOSING A GENERATOR 1...

Страница 33: ...e our production can keep orderly And will continue to make improvement to make sure that keep the competitiveness Welcome friends at home and abroad to visit and guide work together to create brillia...

Отзывы: