INTRODUCTION
UV-C light is electromagnet radiation with wavelengths shorter than visible
light. UV-C can be separated into various wavelength ranges, with the short-
wavelength UV-C considered to be germicidal. Furthermore, and at the
specific wavelength range of 260 to 270 nm, UV-C is found to be mutagenic
to bacteria, viruses and other microorganisms. Germicidal UV-C kills or
inactivates microorganisms by destroying their nucleic acids and disrupting
their DNA, leaving them unable to perform vital cellular functions.
The FirstResponder® Handheld UV-C Sterilizer harnesses the germicidal power of UV-C light, in particular in the 254
nm wavelength. This unit uses shortwave UV-C lamps that emit ultraviolet light with the major peak output (~90%)
band at 253.7 nm. The doped fused quartz glass tubes of the FirstResponder lamps pass the 254 nm radiation (which
produces very low ozone levels) but blocks the 185 nm wavelength (which produce higher ozone levels). The
FirstResponder® Handheld UV-C Sterilizer is intended for use in disinfection of surfaces in laboratories, hospital
rooms, food-processing areas, or any other places where disinfecting and sterilizing are desired.
PRECAUTIONS AND WARNINGS
(a)
Read all instructions before using the devices. Use of these devices is only for intended purposes as described in this manual.
(B)
DO NOT ATTEMPT TO OPERATE THE FIRSTRESPONDER® UV-C STERILIZER WHEN AND WHERE PEOPLE AND ANIMALS ARE PRESENT AND DIRECTLY
EXPOSED TO THE UV-C LIGHT.
(C)
FOR SAFE AND PROPER OPERATIONS, DO NOT TAMPER WITH THE UNITS IN ANY WAY.
(d)
The FirstResponder® UV-C Sterilizer
emits a small amount of ozone gas when operating, which may give off a little bit of odor. This is normal, but to avoid eliminate this
odor if needed, briefly aerate the room after using the sterilizers.
(e)
Do not operate the unit if the cord or plug are damaged, if it is not working properly, or if the unit has been damaged or dropped.
(f)
Do not store the unit outdoors, or use it near open water– for example near filled sinks or water baths.
(g)
Do not attempt to repair or open the unit unless you are a qualified repair technician.
(h)
To avoid injury, handle broken lamps carefully by using protective hand, body, face, and eyewear. Dispose of broken glass in specialized sharps containers and obey all
applicable country and city laws.
DOSAGE RECOMMENDATIONS
Different germs and contaminants are susceptible to UV-C radiation at different rates. To determine the amount of time needed for sterilization,
consult Table 1 on Page 3.
SAFETY NOTIFICATION:
UV-C radiation can damage the superficial tissues of the eye, and care must be taken to avoid excessive exposures to eyes. Glass or plexiglass eyewear or face
mask can provide protection in case the motion sensor safety shut off malfunctions. Also, extended exposure of exposed skin to UV-C make cause damage to
cellular or tissue DNA and should be avoided by wearing protective clothing while near operating UV-C lamps.
Note and Disclaimer
*
The FirstResponder® UV-C Sterilizer is not a replacement or substitute for good cleaning practices. Areas to be sterilized must be free of excess contaminants, especially any
visible liquids or solids (for example bodily fluids, debris or dirt). The FirstResponder sterilizer can eliminate residual surface contaminants, especially bacterial and fungal, but only if
the UV-C light is able to directly impact the contaminated surfaces.
Any surfaces or items that are covered or are behind curtains, glass panels or plastic sheeting will not
be sterilized by the FirstResponder UV-C units.
Genlantis makes no claims and offers no guarantees of any kind that the FirstResponder® UV-C Sterilizer will eliminate 100% of
all contaminants and under all possible circumstances. For best results, users should closely follow the recommended instructions below.
Specifications
Electrical Specifications
120 volts AC, 60 Hz. (E500UVCH) / 220 volts AC, 50 Hz (E520UVCH)
Unit Dimensions (W x D x H)
Including handle: 18 x 5.5 x 6.5 inches (45.7 x 14 x 16.5 cm)
UV-C Output / Dosage
369 µW/cm
2
@ 12 inches; 735 µW/cm
2
@ 6 inches
Weight
1.5 lbs (0.6 kg)
Warranty
1 year
Catalog # Description/Content
Quantity
E500UVCH
FirstResponder® Handheld UV-C-C Sterilizer, 110V
1 Unit
E520UVCH
FirstResponder® Handheld UV-C-C Sterilizer, 220V
1 Unit
Related Products
Catalog #
FirstResponder® Sterilizer, 110V
E4110FRS
FirstResponder® Gear Sterilizer
E600PCM
SteriZAP™ UV-C-C Room Sterilizer, 110V
E500UV-CCT
SteriZAP™ UV-C-C Desktop Sterilizer, 110V
E500UV-CCD
FirstResponder® Duffle Bag Sterilizer, medium
E600DBM
FirstResponder® Duffle Bag Sterilizer, large with wheels
E600DBLW