background image

1.  Pull emergency release cord on carriage to disengage opener to close door if 

necessary. (If unable to lower door using opener, use 

extreme caution manually closing door. Before pulling 

emergency release cord, make certain people and 

objects are clear of door opening.)

2.  Unplug opener power cord from power receptacle.

3.  Open lens cover by pressing outer tabs on both sides 

of motor and swing down to remove light bulbs. FIG. 1. 

4.  Remove wall control and Safe-T-Beam wires from 

terminal block located on rear of opener FIG. 1A. Use 

small common screwdriver to press in on orange tabs 

while gently pulling wires from block. Mark wires to 

help facilitate replacement.

5.  Remove the cotter pin & clevis from door arm to 

separate door from opener. FIG. 2.

6.  Remove motor head and rail assembly from mounting 

brackets/hardware and set on a clean work surface or floor. 

7.  Remove the 3-5/16” bolts from rail to motor mount to remove rail. FIG. 3.

Drive Sprocket Replacement

This repair will require removal of the unit from it’s mounting hardware and repairs made on a bench or floor. Refer to the 

Owners Manual and/or Installation Poster for proper assembly and carefully read and understand all warnings and cautions 

pertaining to the unit. 

FIG. 1.

39187502683

11/2014

 WARNING

 WARNING

BE SURE ELECTRICAL POWER HAS BEEN DISCONNECTED FROM THE INPUT POWER LINES PRIOR TO REMOVING THE 

MOTOR COVER. 

!

 

ANY AND ALL REPAIRS MADE TO THIS UNIT MUST BE PERFORMED WITH THE DOOR DISCONNECTED FROM THE OPENER 

AND IN THE CLOSED POSITION. 

!

Lens Cover Tabs

FIG. 2.

FIG. 3.

6   5   4   3   2   1

Wall Control 1-2

PhotoCells 3-6

Wire Tabs

FIG. 1A.

Отзывы: