![GenICam ICD FLIR AX5 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/genicam/icd-flir-ax5/icd-flir-ax5_manual_2211780006.webp)
Date
1/6/12
© 2011-2012, FLIR Systems AB. All rights reserved worldwide. Publ. No. T 559 775, Rev. B
6 (20)
2.2.2
IP Engine status and control
To establish a connection through the Pleora eBUS SDK, you have to connect using the IP
address of the camera and retrieve a handle to the map of register nodes. Information
about them will automatically be downloaded from the camera.
2.2.2.1
Device Information registers
Registers associated with device information
Name
Type
Access Comment
DeviceVendorName
String
(32)
RO
Provides the name of the manufacturer of the
device.
DeviceModelName
String
(32)
RO
Provides the model of the device.
DeviceVersion
String
(32)
RO
Provides the version of the device.
DeviceManufacturerInfo String
(48)
RO
Provides extended manufacturer information
about the device. *)
DeviceID
String
(16)
RO
This register holds a camera identifier.
DeviceUserID
String
(16)
RW
This register holds a user-programmable
identifier.
DeviceReset
Cmd
WO
Resets the Camera Head and the IP Engine.
CameraSN
Integer RO
Camera module serial number.
SensorSN
Integer RO
Sensor serial number.
CameraFirmwareVersion Integer RO
Camera module software version.
SensorFirmwareVersion Integer RO
Sensor firmware version.
SensorResolution
Enum RO
Sensor resolution
0=Tau2 640x512, 17u
1=Tau2 336x256, 17u
2=Tau2 320x256, 25u
3=Tau2 160x128
4=Tau2 80x64
SensorFocalLength
Enum RO
Sensor focal length in millimeters
0=7.5 mm
1=9 mm
2=13 mm