Synergis IX DIN Rail 2 Door Expander 

SY-SIX-RDM2-DIN-485 

Installation Manual 

 

Содержание Synergis IX SY-SIX-RDM2-DIN-485

Страница 1: ...Synergis IX DIN Rail 2 Door Expander SY SIX RDM2 DIN 485 Installation Manual...

Страница 2: ...tate of a product at the time of document s last revision and may not reflect the product at all times in the future In no event shall Genetec be liable to any person or entity with respect to any los...

Страница 3: ...ram 10 DC Power Encrypted Module Network 11 Door Access Control 12 Wiegand Reader Connection 12 Multiple Wiegand Reader Connection 13 RS 485 Reader Locations 13 RS 485 Reader Connection Entry Only 14...

Страница 4: ...Indicator 23 Fault Indicator 23 Power Indicator 23 Relay Indicators 24 Reader 1 Reader 2 Indicators 24 Zone Input Indicators 24 Error Code Indication 25 Error Code Display 25 Mechanical Diagram 26 Me...

Страница 5: ...ected to the RS 485 module network Up to 64 modules can be connected to the Synergis system in any combination to the network over a distance of up to 900M 3000ft Further span can be achieved with the...

Страница 6: ...ast Updated September 2018 6 Installation Requirements This equipment is to be installed in accordance with The product installation instructions The National Electrical Code ANSI NFPA 70 The Canadian...

Страница 7: ...rical codes These will vary based on country type of distribution system and other factors The integrity of all ground connections should be checked periodically General safety dictates that all metal...

Страница 8: ...closure s DIN Rail Ground Connections multiple cabinets in different rooms sectors or buildings DIN Rail Enclosure Controller Earth Ground Link connection Dialer s Earth Ground Connection Module Netwo...

Страница 9: ...he Reader Expander in a location that will facilitate easy access for wiring It is also recommended that the Reader Expander is installed in electrical rooms communication equipment rooms closets or i...

Страница 10: ...tion Manual Reader 1 2 Data received but format is incorrect Correctly formatted data received Relay 1 2 Red Relay is closed Off Relay is open Input 1 8 Off Input is not programmed Red Input is in the...

Страница 11: ...ed from an independent battery backed power supply unit capable of supplying the required voltage to all devices on the RS 485 network Warning The 12V N and N Communication input must be supplied from...

Страница 12: ...ected at one end of the cable in the metallic enclosure frame grounded Do not connect the shield to a AUX 0V or V connection on the Reader Expander Do not join the shield and black wires at the readin...

Страница 13: ...der port will operate as the exit reader and the normal reader connection shall be programmed to operate as the Entry Reader Shield is frame grounded at one point Shielded Cable RED BLACK GREEN WHITE...

Страница 14: ...1 2 3 4 5 6 7 8 9 0 X V V C BZ L2 L1 D1 D0 NB NA When the green and orange wires are not connected together the reader defaults to an entry reader RS 485 Reader Connection Entry Exit Applies to RS 48...

Страница 15: ...RED BROWN ORANGE OUT COM IN INLINE 5v REGULATOR 50mA MAX OUTPUT 5V 12V 0V 0V V V C BZ L2 L1 D1 D0 NB NA Magnetic card readers are typically operated by 5 volts Before connecting the magnetic card read...

Страница 16: ...on The Reader Expander provides two lock output relays that can be used to switch electric locks Door Lock Outputs 1N4007 Diode 12VDC Electric Locking Device Power Supply for Locking Devices Max 30VDC...

Страница 17: ...ng an input with the EOL resistor configuration the controller generates an alarm condition when the state of an input changes between open and closed and generates a tamper alarm condition when a wir...

Страница 18: ...nfigured in the system and the trouble type and group that they activate Input Number Description Type Group RDxxx 01 05 Reserved None None RDxxx 06 Door 1 Forced Forced Door Access RDxxx 07 Door 2 Fo...

Страница 19: ...ucts and other automation points Lock PGM Outputs 1 and 2 Relays are provided on PGM output 1 and 2 these are used for the Lock 1 PGM1 RD001 01 and Lock2 PGM2 RD001 02 functions and are used to contro...

Страница 20: ...ng device These functions may be disabled by programming the appropriate setting in the Reader Expander configuration PGM Number Description RDxxx 03 LED 1 Green Reader 1 RDxxx 04 LED 2 Red Reader 1 R...

Страница 21: ...Short Beep Access Denied Card Number Not Known The card number is not known in the system The card that has been presented to the reader could not be matched to a valid user in the system 1 Long Beep...

Страница 22: ...Address Configuration The address of the Reader Expander is configured via programming and will require entry of the module serial number The serial number can be found on the identification sticker...

Страница 23: ...n mode enabling the installer to easily identify the module in question Upon either a module update or the identification time period set expiring the module will return to normal operation Fault Indi...

Страница 24: ...not in the correct format Long Flash red A long FLASH 1 Second indicates that the Reader Expander has read the data and the format was correct Zone Input Indicators Whenever an input on the Reader Ex...

Страница 25: ...is not compatible with the system controller To clear this error update the module using the module update application 3 Address Too High The module address is above the maximum number available on t...

Страница 26: ...ough Reader 2 Reader 1 12VDC Input 12VDC Pass Through RS 485 Input Reader 1 12VDC Pass Through Relay 1 Relay 2 Zones 1 to 8 Reader Relay Indicators C BZ L2 L1 D1 D0 V V READER 2 12 VDC OUT C BZ L2 L1...

Страница 27: ...Installation Manual Last Updated September 2018 27 Mechanical Layout The layout shown below outlines the essential details needed to help ensure the correct installation of the Reader Expander 156 8m...

Страница 28: ...w Voltage Restore 10 5VDC Communication RS 485 Module network Offline Operation Offline Access Modes All Users First 10 Users plus 150 Card Cache No Users Readers 2 reader ports that can be configured...

Страница 29: ...e fuses Each reader port supports either Wiegand or RS485 operation but not both at the same time If combining Wiegand and RS 485 technologies they must be connected on separate ports It is important...

Страница 30: ...2 Door Expander Installation Manual Last Updated September 2018 30 New Zealand and Australia General Product Statement The RCM compliance label indicates that the supplier of the device asserts that i...

Страница 31: ...and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of...

Страница 32: ...30 seconds the entry delay has expired or another instant is violated the main alarm will be triggered and reported To comply with EN 50131 1 neither Internals Only on Part Set Zone Alarm nor Interna...

Страница 33: ...on which can be deter mined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient the receiving antenna Incre...

Страница 34: ...Expander Installation Manual Last Updated September 2018 34 Industry Canada Statement This class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme...

Страница 35: ...he Genetec Logo are trademarks of Genetec Inc and may be registered or pending registration in several jurisdictions Other trademarks used in this document may be trademarks of the manufacturers or ve...