Configure MediaRacer 150 and 152 units
For Mavix MediaRacer 150 and 152 units to stream MPEG-4 video properly in Omnicast, you
must ensure that the unit firmware version matches the MPEG-4 version.
1
Open the Mavix Configurator and enter
Administrator
as the default username and
Admin
as the password.
2
Click the
Update Firmware
icon, and click
Manual Update
.
3
Enter the IP address, username, and password of the unit.
4
Under
MediaRacer,
select
IXX
.
5
In the
Unit firmware version
section, click
Read
.
6
Ensure that the
Firmware
version is at least
7.1.1.0
, followed by the letter “
r
”
(eg. 7.1.1.0r).
7
Ensure that the
Codec
is
Mpeg4,
and that the version matches the firmware version listed
above it.