AutoVu SharpX mobile installation
tip.genetec.com | AutoVu Hardware Guide for SharpX Mobile Installation
EN.410.018-XS(6) | Last updated: October 6, 2016
48
NOTE:
If it is impossible to access the inside of the body panel, consider using rivet nuts (not
provided).
3 Attach the camera housing to the camera base and secure the housing by tightening the set
screws with the provided Allen wrench.
NOTE:
You will have to loosen the set screws later to align the camera.
4 Replace any tail light assemblies or trunk liners that were removed for the installation.
Example
Watch this video to learn more. Click the
Captions
icon (
CC
) to turn on video captions in one of the
available languages.
Connecting a wheel imaging camera on a SharpX system
To check whether a parked vehicle has moved through the use of digital tire chalking, you can
connect a wheel imaging camera to the LPR Processing Unit via the Tire/Aux Imaging Adapter
Module.
To connect a wheel imaging camera on a SharpX system
1 The camera cable extension divides the cable into a separate camera cable and power cable.
Terminate the power cable with the 2-pin connector that is included with the Tire/Aux Imaging
Adapter Module.
NOTE:
If you are adding wheel imaging cameras to an older LPR Processing Unit (X1, X2), connect
the camera cable to the AUX VID 1/2 ports, and power the wheel imaging cameras using the AUX
PWR OUT 12V 0.5A MAX port.
2 Attach the Tire/Aux Imaging Adapter Module to camera ports 2 and 4 of the LPR Processing Unit
and tighten the four screws to secure the module.
3 Connect the BNC from the wheel imaging camera to the port with corresponding SharpX camera.