control

– motion – interface

DZ 210

Monitor for Direction of Rotation and Standstill

Simple and compact unit to monitor forward motion,

reverse motion and zero motion

Universal impulse inputs for use with all common incremental

encoders and sensors (HTL, RS422 or TTL)

Two output relays (dry change-over contacts) as well as

two fast-responding power transistor outputs

Wide input frequency range (up to 500 kHz) and

fast response time (<1 msec. with f >1 kHz)

Operating Instructions

3046 Home Road. Powell, OH 43065      P: (740) 917-5781     F: (740) 917-5791     www.GenesisAutomationOnline.com      [email protected]

Содержание moTrona DZ 210

Страница 1: ...th all common incremental encoders and sensors HTL RS422 or TTL Two output relays dry change over contacts as well as two fast responding power transistor outputs Wide input frequency range up to 500...

Страница 2: ...his unit is used with applications where failure or maloperation could cause damage to a machine or hazard to the operating staff it is indispensable to meet effective precautions in order to avoid su...

Страница 3: ...6 Transistor Outputs 6 2 7 The Front LEDs 6 3 Switch Settings 6 3 1 Setup of the Impulse Inputs 6 3 2 Basic Switching Functions 7 3 3 Setting of the Standstill Time T 8 3 4 Definition of Direction of...

Страница 4: ...ls with respect to direction and standstill detection 2 Connections and Terminal Assignments The units provide a 9 position screw terminal strip on the bottom side for power supply and input signals a...

Страница 5: ...witch to any of the following characteristics Impulse formats HTL level 10 30 V TTL level differential respectively RS422 format inverted signals included TTL level single ended without inverted signa...

Страница 6: ...he unit detects standstill 3 Switch Settings 3 1 Setup of the Impulse Inputs Positions 1 to 5 of switch DIL 1 are used to set levels and switching characteristics of the impulse inputs Most of all pra...

Страница 7: ...trigger function see clarification below ON Standstill detection with post trigger function see clarification below 7 OFF Relay 2 and Out 2 to signal the opposite direction of the Rel1 Out1 indication...

Страница 8: ...the switch DIL 2 The table indicates the pause time between two input pulses that must be exceeded in order to signal standstill DIL 2 DIL 2 1 msec ON ON OFF 256 msec ON ON OFF 2 msec ON 512 msec ON...

Страница 9: ...nit must receive a consecutive number of impulses in the corresponding direction The table shows how to set the switches to define the number of impulses required for detection of the direction DIL 2...

Страница 10: ...output already after the very first impulse into the opposite direction With case 2 a window 1 has been set wherewith the short change of the phase between channels A and B does not affect the direct...

Страница 11: ...HIGH 2 5 V Input Impedance NPN and PNP 4 7 kOhms Tristate 10 kOhms Relays Dry change over switching delay approx 5 msec Switching capability 30 VDC 2 A or 125 VAC 0 6 A or 230 VAC 0 3 A Transistor out...

Страница 12: ...2 5 3 248 102 4 016 22 5 0 886 1 2 3 4 5 6 7 8 OFF ON 1 2 3 4 5 6 7 8 OFF ON Side view Top view Front view 3046 Home Road Powell OH 43065 P 740 917 5781 F 740 917 5791 www GenesisAutomationOnline com...