Страница 1: ...WHOLE HOUSE DEHUMIDIFIER Installation Operating and Maintenance Manual ...

Страница 2: ...Maintenance 11 a Filter 11 8 Troubleshooting 11 9 Wiring Diagram 12 10 Physical Dimensions 12 Installation Operation and Maintenance Instructions SAFETY INSTRUCTIONS WARNING This dehumidifier must be installed by a qualified heating ventilation and air conditioning professional in compliance with all codes local and national Failure to comply with this WARNING could result in severe personal injur...

Страница 3: ...ust be considered when determining the location If the unit is mounted above a ceiling or in an attic a secondary drain pan under the entire unit is recommended This pan should have a visible overflow drain that will alert the end user that a problem exists with dehumidifier s primary drainage system SPECIFICATIONS Place the unit in a location that will allow a minimum of 22 clearance for filter r...

Страница 4: ...ING The cabinet must be permanently grounded Connect the ground wire to the Ground terminal provided in the unit Failure to ground the cabinet can result in fire electrical shock personal injury or death The electrical supply requirements are listed on the unit rating plate and in the specification table above CONDENSATE DRAIN The condensate drain must be trapped external to the unit The trap dime...

Страница 5: ... C22 1 and local building electric codes using copper conductors only ALTERNATE REMOTE DEHUMIDISTAT The dehumidifier is supplied with its own self contained dehumidistat control which includes an air sampling sequence however the unit can also be controlled by a remote dehumidistat located in a conditioned space DO NOT LOCATE THE DEHUMIDISTAT IN THE DUCTWORK It is recommended that the remote dehum...

Страница 6: ...er Do not disconnect any of the existing wires from the C W or Y terminals on the air handler furnace Disconnect the existing thermostat wire from the G terminal on the air handler furnace Using a wire nut splice this wire to a new wire and then connect to the G1 terminal on the dehumidifier Connect the G2 terminal on the dehumidifier to the G terminal on the air handler furnace All controls wirin...

Страница 7: ...talled on floor Piped return return Dependent operation furnace blower and dehumidifier must operate at the same time Dehumidifier Connected for Dependent Operation with Vertical Air Handler Furnace Connection Diagram Dependent Operation and per the following Connect the D terminals on the dehumidifier unit to the R terminal on the air handler furnace Do not disconnect any of the existing wires fr...

Страница 8: ...ion Diagram Dependent Operation REMOVE JUMPER ON S1 S2 WHEN OPTIONAL DEHUMIDISTAT IS USED WALL MOUNTED DEHUMIDISTAT OPTIONAL in the space at comfortable levels however there are times during cool or rainy weather when the air conditioning does not operate often enough to keep the humidity at a comfortable level Oftentimes homeowners lower the thermostat to try to compensate for this and cause the ...

Страница 9: ...y This dry air is drawn through the fan and then expelled through the discharge duct back to the conditioned space Dehumidifiers take latent heat heat removed from water vapor when it condenses and convert it to sensible heat heat you can feel in the form of temperature increase This exchange causes the discharge air temperature to be warmer than the entering air temperature The amount of this tem...

Страница 10: ...has become excessively dirty when cleaned at this interval it may be necessary to adjust the cleaning schedule to more frequent cleaning Excess dirt on the filter will reduce the air that can flow through it and reduce the overall effectiveness of the dehumidifier The unit Wiring Diagram is shown on page 11 and the Troubleshooting Guide is on page 12 Insure that power to the dehumidifier unit is t...

Страница 11: ...11 UNIT WIRING DIAGRAM ...

Страница 12: ... dehumidifier is correct Unit door switch is not mechanically actuated due to loose door Dehumidifier operates Filter may be dirty Clean filter continuously but does not Dehumidistat set at unrealistically low setting Reset to dehumidify approximately 50 RH Unit is noisy Ensure unit is sitting level and on all four feet Verify all panel screws are tight Water drips from unit Ensure unit is level V...

Страница 13: ...Whole House Dehumidifier Exploded View 13 ...

Страница 14: ...IDE PANEL RETURN AIR 1 17 7426 TX14 TEX VALVE 1 18 7427 FD14 FILTER DRIER 1 19 7428 CS14 COMPRESSOR 1 20 7429 BT14 BOTTOM PAN 1 21 7430 SD14 PANEL SIDE w INSULATION 1 22 7431 SP14 PANEL FILTER w INSULATION 2 23 7432 PP14 PCB MAIN 1 24 7433 HC14 SENSOR MODULE HUMIDITY W HARNESS 1 25 7434 NC14 KNOB CONTROL 1 26 7435 RI14 ISOLATOR RUBBER 4 27 7436 AF14 FOOT RUBBER ADJUSTABLE 4 28 7437 DS14 SWITCH DOO...

Страница 15: ......

Страница 16: ...Design material performance data and components subject to change without notice 05 23 06 GA1300 06 GENERAL FILTERS INC 43800 Grand River Novi MI 48375 Telephone 866 476 5101 ...