background image

GeneralAire GUV25403A Multivoltage Air Purifier

Installation & Maintenance Instructions

UNPACKING THE UNIT

Each GeneralAire GUV25403A Air Purifier unit is shipped with the ozone

lamp installed and the germicidal lamp placed in a tube with protective

packaging. Carefully remove lamp from the box taking care to not touch

the glass portion of the lamp with bare hands. Oils from the hands can

cause “hot spots” which reduce lamp life. Handle by the porcelain caps or

use a soft cloth. If you accidentally touch a lamp, wipe it off using a soft

cloth dampened with rubbing alcohol. The lamp is fragile and proper care

must be taken when removing from packaging.

Be sure all parts are included in the following list:

• Generalaire GUV25403A Air Purifier

• 16” Germicidal Twin H Lamp

(packed in lamp box)

• Four Sheet Metal Screws

• Installation & maintenance instructions

When installing and using this electrical equipment, basic safety precautions should always be followed including the following:

1. READ AND FOLLOW ALL INSTRUCTIONS.

2. Minimum living space for this product is 1,200 square feet.

3.

Always be sure the unit is unplugged during installation or service procedures.

4.

The ultraviolet light produced by the UV lamp is harmful to your eyes. Do not look directly at

the lamp. Should it become necessary to view the lamp, use UV-protected sunglasses.

Lors de l’installation et de l’utilisation de cet équipement, des précautions devront être suivies.

1- Lire et suivre les étapes attentivement.

2- Espace minimum d’une habitation pour ce produit est de 1,200 pi. carrés

3-

Assurez vous de toujours débrancher avant l installation ou le service.

4-

Ne pas regarder la lampe directement avec les yeux. Si nécessaire de le faire,

veuillez porter les lunettes de soleil contre les rayons U.V.

Pat. Pending

TROUBLESHOOTING

• Under normal operation the LED should light when the furnace blower is running.

• Both lamps operate from the same multivoltage ballast.

If the LED does not light:

1. Check to be sure there is power to the unit.

2. Be sure lamp connectors are fastened securely.

3. If the LED still does not light, replace lamp(s).

4. If still not operating, replace ballast.

(Please note standard off-the-shelf lamps are not compatible with this unit.

Use of improper lamps will void warranty.)

WARRANTY

The manufacturer warrants the GUV25403A air purification unit against defects in materials and

workmanship for a period of four (4) years from the date of installation. Lamps carry a warranty for

the useful life of the lamp, two (2) years. This warranty does not cover broken lamps due to shipping,

installation or handling. This warranty gives you specific legal rights and you may also have other

rights which vary from state to state.

© 2006 For service please call 248-476-5100

16” Germicidal UV-C Lamp

Protective Shield

5” Ozone UV-V Lamp

Ozone

Output

Control

Airstream

Air flow

Furnace

Return

Air Duct

GUV

25403A

Air Purifier

3 1/2”

18 3/4”

Box size is

11.75 high

x 4.25 wide.

IMPORTANT: SAFETY INSTRUCTIONS

IMPORTANT: Instructions de securité

Отзывы: