background image

Installation & Owners Manual

Model 570 (A & M)

Humidifier 

GFI #5710 & 5705

•  Installation by anyone other than a qualified contractor voids the warranty.

•  Product designed for residential installation only. Commercial installation voids warranty.

•  Modification or alteration of product, parts, installation instructions or local safety codes voids warranty.

•  Read our full warranty policy at the end of this document.

®

Please Read And Save These Instructions

Canadian General Filters, Ltd.

400 Midwest Rd. 

Toronto, ON M1P3A9 Canada

Toll Free:  (888) 216-9184

www.cgfproducts.com

General Filters, Inc.

43800 Grand River Avenue

Novi, Michigan 48375

Toll Free: (866) 476-5101

www.generalaire.com

Содержание 5705

Страница 1: ...anty Modification or alteration of product parts installation instructions or local safety codes voids warranty Read our full warranty policy at the end of this document Please Read And Save These Instructions Canadian General Filters Ltd 400 Midwest Rd Toronto ON M1P3A9 Canada Toll Free 888 216 9184 www cgfproducts com General Filters Inc 43800 Grand River Avenue Novi Michigan 48375 Toll Free 866...

Страница 2: ...he Control 6 How The Humidifier Works 7 Maintenance 7 Parts Drawing 8 Inside Your Box 8 Humidifier Chassis Cut Out 9 Trouble Shooting 9 FAQ s 10 Limited Warranty 11 12 Model 570 Table of Contents WARNING This symbol indicates IMPORTANT INSTRUCTIONS Failure to heed them can result in serious injury or death CAUTION This symbol indicates IMPORTANT INSTRUCTIONS Failure to heed them can result in seri...

Страница 3: ...Installation Warm Air Return Air Plenum Right or Left Side Plenum Opening Inches 8 7 8 W x 9 1 2 H Bypass Opening Inches 6 Pallet Qty 36 Cabinet Construction UV Stable Automotive Grade Plastic Humidistat Included M Models MHX3C A Models GFX3 Voltage 24VAC In The Box Humidifier Humidistat Control Bypass Damper 24V Transformer Solenoid Valve Vapor Pad Saddle Valve GCV3412 Code Valve A Models Install...

Страница 4: ...de of humidifier on cabinet centerline using connecting collar as guide The bypass is reversible and can be mounted on the right or left side of the humidifier 2 The humidifier is self retaining Slide the top side in first then slide the chassis down Level the chassis and install center screws If the by pass pipe installs to opposite side of chassis bend clip on chassis remove side panel and reins...

Страница 5: ...her a cold or a hot water pipe A side or top mount is best to avoid clogging from pipe sediment Connect 1 4 O D tubing to the saddle valve Copper tubing requires a brass compression nut and brass sleeve Plastic tubing requires a brass insert inside the tubing a plastic sleeve on the outside with a brass compression nut CAUTION Do not use plastic tubing on hot water or in contact with any hot plenu...

Страница 6: ...OOR TEMP SENSOR N W 24v 60CY ACC EAC HOT C 115v 60CY ON OFF SWITCH COMMON LEAD FURNACE C HI LO GA50 CURRENT SENSING RELAY MULTI SPEED BLOWER MOTOR 24V SOLENOID VALVE HUMIDISTAT 24 V TRANSFORMER HOT C 115v 60CY ON OFF SWITCH 24V SOLENOID VALVE 24V SOLENOID VALVE 24 V TRANSFORMER L1 C NO HOT L2 115v 60CY ON OFF SWITCH 12500 AIR PRESSURE SWITCH 24 V TRANSFORMER HUM FURNACE CONTROL BOARD C 24v 60CY 24...

Страница 7: ...se water supply valve switch electrical power off and turn humidistat off If furnace is used for summer cooling or ventilating set air damper to the SUMMER position How The Humidifier Works At Outside Temperature Recommended Setting 20 F 29 C 15 10 F 23 C 20 0 F 18 F 25 10 F 12 C 30 20 F 7 C 35 30 F 1 C 40 Maintenance Your humidifier is engineered to give helpful and trouble free humidification Fo...

Страница 8: ...Solenoid Assembly Integral Bypass Damper Accessories MHX3C Manual Humidistat 24V Transformer Saddle Valve Parts Drawing 900 14 DRAIN PAN 900 11 DAMPER KNOB 900 28 DAMPER DISK 570 2 SIDE PANEL DISCHARGE 570 40 PAD RAIL GA 10 EVAPORATOR PAD 900 15 DISTRIBUTOR TROUGH 570 13 COVER GA4231 YELLOW ORIFICE P190 COMP SLEEVE PLASTIC P102 COMP SLEEVE BRASS P101 COMPRESSION NUT 570 1 CHASSIS 900 9 NOZZLE 900 ...

Страница 9: ... be caused by any of the following Verify water supply is on Verify metering orifice is not obstructed Very hard water with high mineral content may restrict the metering orifice in as little as one heating season Replace Yellow metering orifice GA4231 if restricted GFI 7580 3 The humidifier runs without furnace operation or humidifier never shuts off Check for the following Verify humidifier and ...

Страница 10: ...ater flow If you subject the pad to cleaning you usually remove much of the coating and the pad becomes ineffective This reduces the output of the humidifier and increases water consumption Replace the Vapor Pad annually 5 Why would I want to install a humidifier For many reasons 1 Since the air in your home is always trying to reach its saturation point it will absorb water wherever it can from t...

Страница 11: ...ervicing or replacing parts is not covered under this Limited Warranty What is Not Covered Cont Shipping charges are not covered by this Limited Warranty Agreements made by third parties that are not listed in this Limited Warranty Liability for special incidental direct indirect collateral and consequential damages is excluded Some states do not allow limitation of incidental damages so the limit...

Страница 12: ...manufacturer will in no event be liable for incidental or consequential damages This limited warranty gives you specific legal rights and you may also have other rights which vary from state to state Some states do not allow either limitations on implied warranties or exclusions from incidental or consequential damages so the above exclusion and limitation may not apply to you Questions Any questi...

Страница 13: ...pression REMARQUE NE PAS UTILISER DE TUYAUX EN PLASTIQUE AVEC DE L EAU CHAUDE OU SUR UNE SURFACE DE CONTACT CHAUDE DE PLÉNUM OU DE CONDUIT L INSTALLATION DE CE ROBINET VANNE À ÉTRIER DOIT RESPECTER OU DÉPASSER LES EXIGENCES DES CODES LOCAUX ET AUTRES ORDONNANCES 4 2 1 2 DÉBIT D AIR VERS LE HAUT RETOUR D AIR AIR CHAUD DRAIN 15 2 cm 6 po 24 1 cm 9 1 2 po 22 5 cm 8 7 8 po Le modèle 570 de peut être i...

Страница 14: ...V 60 Hz COMMUTATEUR DE MARCHE ARRÊT 12500 PRESSOSTAT D AIR TRANSFORMATEUR DE 24 V HUM C 24 V 60 Hz VANNE ÉLECTROMAGNÉTIQUE DE 24 V HUMIDISTAT HUMIDISTAT HUMIDISTAT 7E 7G 7F 7H 7A à 7D Humidistat électronique 7A Vers la carte de circuits imprimés de l appareil de chauffage de 24 volts 7B Vers la source d alimentation constante utilisant un transformateur de 24 V et un manostat 7C Vers la carte de c...

Страница 15: ...nt lorsque le ventilateur de l appareil de chauffage est en marche ou que le circuit du brûleur est activé L humidificateur est maintenant prêt à fonctionner 6 Pendant la période estivale fermer l alimentation en eau et en électricité de l humidificateur Fermer le registre à air SOIN ET ENTRETIEN GARANTIE LIMITÉE Cet humidificateur lorsqu il est enregistré correctement en retournant la carte d enr...

Страница 16: ... pi2 164 m2 1770 pi2 279 m2 3000 pi2 34 9 cm 13 3 4 po 39 4 cm 15 1 2 po 33 6 cm 13 1 4 po CARACTÉRISTIQUES DE L HUMIDIFICATEUR ELITE 570 Performance d humidité prévue selon la superficie en mètres carrés pieds carrés et le type de construction ACCESSOIRES DES COMPOSANTS DE L HUMIDIFICATEUR EMBALLÉ Critères de base de la performance de l humidificateur 34 1 cm 9 1 2 po 22 5 cm 8 7 8 po ÉTÉ HIVER G...

Отзывы: