TS4000H
35
3. Apply and remove the magnet to see the sensor range appears on the display. Apply the
magnet to cycle through the ranges, and remove the magnet to select the correct range on
the display. When “
Fi
” of the sensor range menu displays, apply and remove the magnet to
exit this menu.
4. Once the correct sensor range is selected, the unit returns to the Setup Menu and depicts
“
Lo
” on the display.
5. When
“
Fi
” displays again, apply and remove the magnet to exit the Setup Menu and return
to normal operation.
NOTE:
When the Sensor Range is changed, the Warning and Alarm set points are
automatically scaled to the new range. The unit must now be calibrated to the new
range. Refer to Section 4.9.
CAUTION:
A fault occurs if the user does not complete the menu cycle. For more information
about faults and fault codes, refer to Section 7.1.
4.6.2 Warning Relay Settings
The user can adjust the Warning Relay Settings for all sensors. The factory default settings and
adjustment range for all gases other than O
2
are as follows:
Non-latching
(default)
De-energized
(default)
30% FS set point (default)
5% of FS (minimum)
Alarm relay set point (maximum)
The default settings and adjustment range for O
2
are:
19.5% by volume (default)
Alarm Relay set point (minimum)
NOTE:
In general, most configuration procedures apply to all sensors. However, there are
instances when a unique procedure is required for a given sensor or sensors.
Wherever applicable, both generic and unique procedures are detailed in this manual.