Xedge Chassis Systems
Xedge 6640/6645 Chassis
032R440-000
Xedge 6000 Hardware
2-31
Issue 17
Installation & Setup Guide
Table 2-10
Xedge 6640/6645 Rear Panel Controls & Connectors
Location
Connector
Type
Function
Alarm/Status
Connector
Panel
PSU A + B
Power Supply Unit A and B
grounded AC IEC-
320 receptacle
Provides connection for an AC power
source for the power supplies in slots A and
B.
PSU C + D
Power Supply Unit C and D
grounded AC IEC-
320 receptacle
Provides connection for AC power source
for the power supplies in slots C and D.
N.O. CRITICAL
Normally Open Critical alarm
3-position header
Provides connection to alarm relay contact
that opens when a critical alarm occurs.
C. CRITICAL
Common Critical alarm
3-position header
Provides the common connection for the
critical alarm relay.
N.C. CRITICAL
Normally Closed Critical alarm
3-position header
Provides connection to alarm relay contact
that closes when a critical alarm occurs.
N.O. MAJOR
Normally Open Major alarm
3-position header
Provides connection to alarm relay contact
that opens when a major alarm trap occurs.
C. MAJOR
Common Major alarm
3-position header
Provides the common connection for the
major alarm relay.
N.C. MAJOR
Normally Closed Major alarm
3-position header
Provides connection to alarm relay contact
that closes when a major alarm occurs.
N.O. MINOR
Normally Open Minor alarm
3-position header
Provides connection to alarm relay contact
that opens when a minor alarm occurs.
C. MINOR
Common Minor alarm
3-position header
Provides the common connection for the
minor alarm relay.
N.C. MINOR
Normally Closed Minor alarm
3-position header
Provides connection to alarm relay contact
that closes when a minor alarm occurs.
N.O. AUDIBLE
Normally Open Audible alarm
3-position header
Provides connection to alarm relay that
opens when a critical, major or minor alarm
occurs. Disabled by ACO function.
C. AUDIBLE
Common Audible alarm
3-position header
Provides the common connection for the
audible alarm relay.
N.C. AUDIBLE
Normally Closed Audible alarm
3-position header
Provides connection to alarm relay that
closes when a critical, major or minor alarm
trap occurs. Disabled by ACO function.
S1-A STATUS INPUTS
S1-B STATUS INPUTS
5-position header
Provides connections for an external device
that inputs one user-configurable status.
S2-A STATUS INPUTS
S2-B STATUS INPUTS
5-position header
Provides connections for external device
that inputs a 2nd user-configurable status.
Frame ground
screw terminal
Provides connection to frame ground.
Shorting bar connects frame ground to
signal ground, if required.
Signal Ground
screw terminal
Provides connection to signal ground.
Shorting bar connects frame ground to
signal ground, if required.
System MGMT
Panel
MANAGER (MAIN)
female D25
Provides connection to the craft (local)
management interface of main slot-0.
MANAGER (STANDBY)
female D25
Provides connection to the craft (local)
management interface of standby slot 0.
ON/OFF MAIN
2-position key
Enables
ON (1)
and disables
OFF(0)
craft port access to the main slot 0.
ON/OFF STANDBY
2-position key
Enables
ON (1)
and disables
OFF(0)
craft port access to the standby slot 0.