For non-redundant power supplies and a single station battery source:
1. Connect the positive side of the battery to the terminals marked
+V
on both power entry
modules.
2. Connect the negative side of the battery to the terminals marked
-V
on both power entry
modules.
For redundant power supplies and dual station battery source:
1. Connect the positive side of one battery to the terminal marked
+V
on the “A” power input
module.
2. Connect the negative side of the same battery to the terminal marked
-V
on the “A” power
input module.
3. Connect the positive side of the second battery to the terminal marked
+V
on the “B” power
input module.
4. Connect the negative side of the second battery to the terminal marked
-V
on the “B” power
input module.
Figure 2-7