SC-ADT Configuration
Configuring SC-ADT for Typical Applications
3-4
SpectraComm ADT
076R172-000
Installation and Operation Manual
Issue 2
Configuring SC-ADT for Typical Applications
The following procedure configures the SC-ADT for a typical deployment in your network as an
async terminal server or as an async data transport device. Procedures are the same for the 16-port
or 32-port device except where noted. Before configuring the SC-ADT, ensure that the unit has
already been initialized as described in the previous section:
Note
Some ADMIN mode configuration commands (i.e., enabling the craft port or setting up user accounts)
cannot be accessed or executed via the web interface.
Note
In the configuration sample below, [brackets] indicate user-defined entries or typical entries. For the default
of any configuration setting, use the online help or refer to the listing in
Appendix A, Application Guidelines
Basic Configuration
Management Configuration Settings
The first three steps of this procedure are required in order to configure the SC-ADT for
management. You must change the SC-ADT from its default settings, as shown. Throughout this
procedure you can type
?
following any command, sub-command or parameter for context-
sensitive online help.
1. Configure the HTTP Service to enable access by typing:
services http enable
2. Configure the SNMP Service to enable access by typing:
services snmp enable
3. If desired, enable management access via ethernet (the default setting) by typing:
services telnet enable
Optional Configuration Settings
The remaining steps use default values pre-loaded in the SC-ADT unit. If the default value applies
to your network, you do not need to re-enter it. Otherwise, enter the value that best suits your
network environment. Type
?
following any command, sub-command or parameter for context-
sensitive online help.
4. Set the system prompt by typing:
configure prompt
[ADT-16] or [ADT-32]
5. Configure the Inactivity Timer to disconnect a management session after the desired interval
(in seconds) has elapsed. Range is 0 - 10,000 sec, where 0 disables the timer.
configure inactivity
[900]