076R172-000
SpectraComm ADT
5-1
Issue 2
Installation and Operation Manual
Chapter 5:
Additional Features
Overview of Additional Features
The SC-ADT supports the following additional features:
•
Time Protocols
•
Authentication Protocol
•
Contact Sense
•
Connect/Disconnect Controls
•
Chat CLI Communication
•
Telnet Menu
•
System Message Log and Alarm Log
•
SNMP Traps
Time Protocols
SC-ADT supports Simple Network Time Protocol (RFC2030) and Time Protocol (RFC 868). When
configured for SNTP or TP, SC-ADT will receive and use Greenwich Mean Time (GMT) to
timestamp the SNMP traps, System Messages and Alarms when they are generated.
When neither SNTP nor TP is configured, the SC-ADT will use a relative System Up Time for
timestamping.
SNTP/TP Client Configuration Procedure
1. Configure SC-ADT for receiving GMT, type:
configure time server add
[SNTP or TP server IP address]
2. Configure SC-ADT for either SNTP or TP by typing one of the following commands:
•
To configure SC-ADT for SNTP, type:
configure time protocol sntp
[SNTP version number]
•
To configure SC-ADT for TP, type:
configure time protocol tp
3. Enable the desired protocol by typing:
configure enable time
Note
To verify the configuration, type
show time
.