background image

Installation & Connections

Shelf and Card Connections

076R172-000

SpectraComm ADT  

2-5

Issue 2

Installation and Operation Manual

 

Figure 2-1

SC-ADT Connections (16-port Device)

SPECTRACOMM
SHELF BACK PANEL

SC 2000 SHELF
BACK PANEL

SC 1001/1002 ENCLOSURE 
BACK PANEL

J32
J48

J31
J47

J30
J46

J29
J45

J28
J44

J27
J43

J26
J42

J25
J41

J24
J40

J23
J39

J22
J38

J21
J37

J20
J36

J19
J35

J18
J34

J17
J33

J52

J14

J12

J11

J16

J15

J13

J10

J9

J8

J7

J6

J5

J2

J1

J4

J3

J51

J50

CONNECTOR 

DETAILS

ETHERNET
(LAN) PORT

B

A

INTERNAL
MODEM/LINE
ONLY

B

D

B

A

SC-ADT 16-PORT CONNECTIVITY 

PIN
1

FRONT PANEL

VIEW

CRAFT PORT/
CONTACT
SENSE

D

8
7
6
5
4
3
2
1

TERMINAL/
TRANSPORT
PORTS 1 - 8,
PORTS 9 - 16

C

PIN 8

PIN 1

(TYPICAL)

NTWK A

NTWK B

TERM

BUSINESS EQUIP.

B

A

D

MASS TERMINATION  CONNECTIONS 

J19

J18

J17

J22

J21

J20

J52

J14

J12

J11

J16

J15

J13

J10

J9

J8

J7

J6

J5

J2

J1

J4

J3

J51

J50

UNIVERSAL BACKPLANE 

ZONE 1

E

F

MASS TERM
INTERNAL
MODEM/LINE

E

MASS TERM
ETHERNET
(LAN) PORT

F

SC 5000 SHELF

1

8

2

3

4

5

6

7

ON
AL

IN
TM

ENET
1

MDM
1

MDM
2

9

16

10

11

12

13

14

15

SC ADT

1-8

9-16

PORT

C

PIN
1

PIN
1

A

D

NOTE:
INTERFACE "A" IS NOT USED
BY EXTERNAL MODEMS.

NOTE:
EXTERNAL MODEMS 
CAN ONLY USE 
PORT1 OR PORT2.

8 INPUTS

Содержание SpectraComm ADT 16-Port

Страница 1: ...The Best Connections in the Business General DataComm 6SHFWUD RPP 7 Asynchronous Data Transport Installation Operation Manual 076R172 000 Issue 2 June 2004...

Страница 2: ...demarks or registered trademarks of their respective companies or organizations Documentation Revision History GDC P N 076R172 000 Related Publications REV is the hardware revision 000 001 etc VREF is...

Страница 3: ...sure Options 1 6 SC ADT Front Panel Interface 1 7 SC ADT Applications Overview 1 8 A Terminal Server Application 1 9 A Transport Mode Application 1 10 A Contact Sense Application 1 11 Technical Specif...

Страница 4: ...Line Web Screen 4 3 Chapter 5 Additional Features Overview of Additional Features 5 1 Time Protocols 5 1 TACACS Authentication Protocol 5 2 Contact Sense 5 6 Connection Controls 5 8 Chat Communicatio...

Страница 5: ...203 729 0271 Toll Free 1 800 523 1737 Manual Organization This manual is divided into the following chapters When using the digital version of this manual click on any link shown in blue text to jump...

Страница 6: ...telephone wiring during an electrical storm Antistatic Precautions This product may contain static sensitive devices that are easily damaged by ESD electrostatic discharge ESD occurs when a person who...

Страница 7: ...ny will notify you in advance that temporary discontinuance of service may be required But if advance notice is not practical the telephone company will notify you as soon as possible Also you will be...

Страница 8: ...present are connected together This precaution may be particularly important in rural areas Caution Users should not attempt to make such connections themselves but should contact the appropriate elec...

Страница 9: ...ctricien selon le cas Avis L indice d quivalence de la sonnerie IES assign chaque dispositif terminal indique le nombre maximal de terminaux qui peuvent tre raccord s une interface La terminaison d un...

Страница 10: ...y Direct Support Repair GDC provides regular and warranty repair services through Factory Direct Support Repair at its U S headquarters in Naugatuck Connecticut This customer support organization repa...

Страница 11: ...Port Device The SC ADT 16 port card is a single width 7 inch by 9 5 inch 178 mm by 241 mm printed circuit card that provisions 16 async ports via the two front panel connector assemblies The SC ADT c...

Страница 12: ...otiates for 10 or 100 Mbps port speed full or half duplex modes and enabled disabled flow control Ethernet port auto senses HP MID X for straight thru or crossover cable connections High performance r...

Страница 13: ...es the Ethernet LAN interface for connecting the SC ADT to any standard 10 100B T LAN device including PCs servers hubs and switches Modem Ports M0 and M1 The SC ADT supports up to two external GDC Sp...

Страница 14: ...eme traffic conditions the SC ADT will handle an aggregate rate of 800 000 bits per second full duplex This translates to 50 000 bits per second per port if using sixteen async ports and 25 000 bits p...

Страница 15: ...anagement via HTTP for internet ready network monitoring An embedded web server agent allows Read or Read Write access to the SC ADT using popular browsers To enhance security the SC ADT supports web...

Страница 16: ...gure 1 1 Shelf Enclosure Configurations SPECTRACOMM 2000 SC 2000 SHELF SLOTS 1 2 POWER SUPPLY POWER ON General DataComm SC ADT 16 PORT General DataComm SC 5000 SHELF SLOTS 1 16 SC MULTIPAK ENCLOSURE S...

Страница 17: ...ion ON AL Steady GREEN indicates power is supplied to the unit Future Use Steady RED indicates a major alarm condition IN TM Steady GREEN indicates the device is in service Steady RED indicates one or...

Страница 18: ...led in the pages that follow the figure Figure 1 2 SpectraComm ADT End to End Applications Contact Relay Ports 1 8 Contact Relay Ports 1 8 REMOTE SITE A Remote Sites A and B SC ADT 16 port device with...

Страница 19: ...the PSTN The external modems use async Port 1 or Port 2 The integral modems use the modem line RJ45 connector at the shelf enclosure rear panel Dial in users connect to SC ADT in Terminal Emulation m...

Страница 20: ...pters allow connections to either terminal DTE or modem DCE devices Figure 1 4 shows multiple sites with async equipment linked together over the customer s IP Network Any DTE at any SC ADT site can e...

Страница 21: ...ansport Future option The alarm will be transported between sites and a Trap will be sent to a management station destinations for alarm transport and Trap are independent SC ADT devices are required...

Страница 22: ...onal Characteristics Data Rates 300 600 1200 2400 4800 9600 19200 38400 57600 115200 bps Modem Parameters ITU T V 34 with 9600 bps to 33 6 Kbps line speed DTE speed up to 115 2 Kbps using V 42 LAPM an...

Страница 23: ...Compliant with GR 63 Core Section 4 3 for Category A and Category B Containers NEBS Level III Compliant with GR 1089 Core GR 63 Core GR 78 Core EMI FCC Part 15 Class A Telco FCC Part 68 Approved Immun...

Страница 24: ...Introduction Specifications Technical Specifications 1 14 SpectraComm ADT 076R172 000 Installation and Operation Manual Issue 2...

Страница 25: ...erminal Server or Transport device Shelf Enclosure Installation Guidelines Locate the SpectraComm shelf in a ventilated area where the ambient temperature does not exceed environmental specifications...

Страница 26: ...two V 34 modems 115 VAC standalone 10 100Base T Ethernet 076A046 021 SC ADT 16 port with two V 34 modems 230 VAC standalone 10 100Base T Ethernet 076A046 022 SC ADT Expan 32 port rackmount 10 100Base...

Страница 27: ...rs 3 Attach the card retention bar if provided Note If you are installing the SC ADT in a SC 2000 shelf do not wall mount the shelf Wallmounting does not provide sufficient strain relief for the front...

Страница 28: ...nal modem and one of the two internal modems When the SC ADT device is to use one or two external modems each external modem must be connected to Async Port1 or Async Port2 of the SC ADT A DTE adapter...

Страница 29: ...N PORT B A INTERNAL MODEM LINE ONLY B D B A SC ADT 16 PORT CONNECTIVITY PIN 1 FRONT PANEL VIEW CRAFT PORT CONTACT SENSE D 8 7 6 5 4 3 2 1 TERMINAL TRANSPORT PORTS 1 8 PORTS 9 16 C PIN 8 PIN 1 TYPICAL...

Страница 30: ...J2 J1 J4 J3 J51 J50 SHELF ADDRESS JUMPER A D CONNECTOR DETAILS ETHERNET LAN PORT B A INTERNAL MODEM LINE ONLY B B B SC ADT 32 PORT CONNECTIVITY PIN 1 FRONT PANEL VIEW CRAFT PORT CONTACT SENSE D 8 7 6...

Страница 31: ...rs located at the Expansion card rear panel J17 J23 and J33 J48 These Ethernet ports provides 10 100BASE T Ethernet connectivity and require RJ45 to RJ45 straight thru or crossover cables GDC S 078H01...

Страница 32: ...Pin1 CTS 39 Port 5 Pin1 CTS 55 Pin 2 DCD 5 Pin 2 DCD 21 Pin 3 RXD 38 Pin 3 RXD 54 Pin 4 RXD GND 4 Pin 4 RXD GND 20 Pin 5 TXD GND 37 Pin 5 TXD GND 53 Pin 6 TXD 3 Pin 6 TXD 19 Pin 7 DTR 36 Pin 7 DTR 52...

Страница 33: ...To SC ADT Transmit Data Supervisory data from the terminal 3 Craft Out From SC ADT Receive Data Supervisory data to the terminal 7 Craft GND Signal ground for craft interface Contact Sense 5 Out 1 GN...

Страница 34: ...Installation Connections Shelf and Card Connections 2 10 SpectraCommADT 076R172 000 Installation and Operation Manual Issue 2...

Страница 35: ...mands shown below If you are in User mode some commands shown below will not display _______________________System Commands______________________________ clear Reset functions configure Connect to ter...

Страница 36: ...0 0 Use at any time on the command line to get help SC ADT16 Note For online help screens describing all CLI options press Note that the CLI options for configuring the SC ADT are only available when...

Страница 37: ...cess plus the ability to set up and modify user accounts for usernames and passwords ADMIN mode also allows authentication for the CRAFT port to be turned on or off Note Some ADMIN mode configuration...

Страница 38: ...Management Configuration Settings The first three steps of this procedure are required in order to configure the SC ADT for management You must change the SC ADT from its default settings as shown Th...

Страница 39: ...name configure snmp system contact your system contact configure snmp system location your system location Creating a Login Banner SC ADT is shipped from the factory with no Login banner When you com...

Страница 40: ...ne line at a time type configure banner modify your revised text string esc char where is the line number you intend to change Use the double quoted string format to type your revised text for that li...

Страница 41: ...ectivity Note Refer to the procedure on Modem Configuration in this chapter for additional modem options If your SC ADT device is not equipped with internal modems or attached to compatible external m...

Страница 42: ...ote device 5 Enable each configured Terminal Server or Transport port by typing configure ports enable port or all For example configure ports enable all Note For Transport applications the ports enab...

Страница 43: ...ditional Features Special Consideration Modem Use If Port1 and or Port2 are configured for use by an external modem these ports will be disabled as user ports Terminal Server ports or Transport ports...

Страница 44: ...llowing steps to properly change the port mode 1 Use the chat call command to notify another users that you are intentionally disabling the link See Chapter 5 Additional Features for information on th...

Страница 45: ...xternal modems are properly connected to Port1 and or Port 2 Refer to Chapter 2 under Modem Connections as needed 2 Configure each modem interface required for dial in networking by typing configure i...

Страница 46: ...e configuration guidelines 7 To configure the answer mode of the modem type configure modem mode modem n callback or auto answer 8 If the mode is set to callback configure the callback parameters by t...

Страница 47: ...Configuring SC ADT for Typical Applications 076R172 000 SpectraCommADT 3 13 Issue 2 Installation and Operation Manual show modem callback modem n show modem mode modem n show modem use n Figure 3 3 Ty...

Страница 48: ...SC ADT Configuration Configuring SC ADT for Typical Applications 3 14 SpectraCommADT 076R172 000 Installation and Operation Manual Issue 2...

Страница 49: ...gh 5 x are supported Internet Explorer 5 0 or higher Cookies must be enabled Note At the terminal or craft interface you can toggle http disable enable to clear all cookies 2 Via the Telnet or the Cra...

Страница 50: ...privileges as assigned by an Administrator A valid password can be up to 20 alphanumeric characters If three consecutive invalid passwords are entered a temporary lock out will occur Access Modes Acce...

Страница 51: ...st logout of the web interface and make a Telnet or terminal connection in ADMIN mode to access execute those commands Table 4 1 Command Line Web Screen Field Description clear Displays a selectable l...

Страница 52: ...The Web Interface Introduction to Web Management 4 4 SpectraComm ADT 076R172 000 Installation and Operation Manual Issue 2...

Страница 53: ...l receive and use Greenwich Mean Time GMT to timestamp the SNMP traps System Messages and Alarms when they are generated When neither SNTP nor TP is configured the SC ADT will use a relative System Up...

Страница 54: ...TACACS server When TACACS is enabled the TACACS server becomes the central point for managing network wide usernames and passwords This is especially useful when provisioning SC ADT devices in large n...

Страница 55: ...onsiderations for using TACACS authentication listed at the end of this section Note You must log in with ADMIN privileges to execute the commands in this procedure 1 At the prompt type enable 2 Type...

Страница 56: ...type configure tacacs banner tacacs description configure tacacs banner local description TACACS Verification Procedure When a SC ADT device is enabled for TACACS authentication it is highly recommen...

Страница 57: ...typing L 4 Use the default passwords to reconfigure the SC ADT from scratch TACACS Special Considerations In order to change local authentication configuration values or enable and configure TACACS au...

Страница 58: ...Contact Sense for all ports simultaneously Each contact port must be configured as Normally Opened or Normally Closed A closed condition on a normally opened port will cause an ACTIVE condition Likewi...

Страница 59: ...enter an alphanumeric description of the contact port by typing configure contact description c contact description Note If a space is desirable in the description you must use a double quoted string...

Страница 60: ...CLI across the IP network 2 The calling CLI user initiates a text message session with the remote user by typing chat call remote unit IP address 3 A split window appears where the remote user then t...

Страница 61: ...ts that do not display in the Telnet menu i e Port8 and Port9 in the example below are not enabled or have been configured for Transport mode Figure 5 3 Telnet Menu Selections Telnet Access Procedure...

Страница 62: ...the last 100 SYS MSG events saved to the log Use this log to examine link status diagnostic test activity etc The System Message log is not saved when the unit reboots To show the last 100 logged even...

Страница 63: ...ar such information by interface by port or globally To access the help for the clear commands type To access the help for clear commands type clear To clear collected data on one particular port type...

Страница 64: ...d trap is sent Each SNMP trap is time stamped with a relative System Up Time default or with GMT if so configured refer to Time Protocols in this chapter SNMP Trap Configuration To configure SC ADT to...

Страница 65: ...or cannot be used as username logins They are only used to enable the supervisor admin mode The only default username login is defined as gdc with the password gdc This username may be deleted or its...

Страница 66: ...g 20 chars max ADT 16 or ADT 32 CLI Inactivity Timer Disconnects CLI session after the desired interval in secs has elapsed 0 to 10 000 use 0 to disable 900 HTTP Service HTTP server support for web ma...

Страница 67: ...ending data The XOFF character 13H is used to tell the terminal to stop sending data The XON character 11H tells the terminal to begin sending data again Hardware flow control is achieved by raising a...

Страница 68: ...e the configuration of the device A read write community name allows user to gather statistics and remotely configure the device The device supports MIB II system group SNMP traps Sends unit and port...

Страница 69: ...fore trying the next server on the list 1 to 10 seconds 5 Configure Time Controls the use of Simple Network Time Protocol RFC2030 and Time Protocol RFC 868 Enable or Disable Note When configured for S...

Страница 70: ...When you type the character at the beginning of a command line the screen displays all the commands available along with a one line description of each command ADT 16 _______________________System Com...

Страница 71: ...meter s interfaces Configure interface parameters ip route Configure static route table modem Configure modem parameters ports Configure port parameters prompt Configure custom prompt requires 1 param...

Страница 72: ...1 255 Entering a Command String Each command string is executed by pressing the Enter key or cr The general syntax is command subcommand s if any required argument s if any Aborting a Command Use the...

Страница 73: ...perTerminal at the CTRL interface Users can initially setup the SC ADT from a predefined configuration file rather than entering one command at a time Special Considerations for Batch Files You must b...

Страница 74: ...r faces you intend to use and that the modem IP address is properly configured 2 Check that the conf modem use command is properly set for internal or external modem 3 For the SC V F28 8 33 6 modem ch...

Страница 75: ......

Страница 76: ...The Best Connections in the Business...

Отзывы: