SC-ADT Configuration
Telnet/SSH Management Overview
3-8
SpectraComm ADT
076R172-000
Installation and Operation Manual
Issue 6
Telnet/SSH Cut-Thru Procedure via Dial-out Modems
This procedure is for SC-ADT applications that employ a modem bank in front of the target device,
or when the async RS232 format for a remote craft device cannot be known by the ADT. The
Telnet/SSH caller must include a special character command in the cut-thru port number to auto-
configure the ADT port to match the intended craft device, as shown in the example below.
Figure 3-2
Auto-Configuring ADT Port Async RS-232 Format
1. Start a Telnet or SSH session to a specific port by defining the following Telnet or SSH
connection parameters, with the autoconfig code number as required (1 - 5).
telnet
[SC-ADT IP address]
2
[config code #][2-digit port number]
ssh
[SC-ADT IP address]
3
[config code #][2-digit port number]
For Example: Cut-Thru to Port 6 with port auto-config to 7M1 (code #4):
telnet 172.16.45.204 2406
or
ssh 172.16.45.204 3406
where
[n] is the auto-config code number that overrides the SC-ADT port’s async RS232
format with a temporary configuration for the duration of the call.
2. Login with a valid username and password as required.
3. A successful Telnet/SSH cut-thru connection to the port will display a confirmation string.
Note
The SC-ADT port will not be able to make a Telnet/SSH connection if its Async RS-232 format does not match
that of the intended craft device. Repeat this procedure using a different code number as needed.
4. After disconnecting the call, the SC-ADT port will revert to the original async RS232 format.
SC-ADT
Port 1
Port 2
Port 5
Port 6
Port N
MODEM
MODEM
MODEM
MODEM
MODEM
MODEM BANK
7N1
7E1
Craft
Devices
8N1
7M1
7S1
Using 2406 (Telnet)
or 3406 (SSH)
Databits Parity
Stop Bits
None
Even
Odd
Mark
Space
1
1
1
1
1
8
7
7
7
7
( DISABLED )
Async RS232 Formats
Telnet/SSH Cut-Thru with Auto-Config
Destination Device
uses 7M1 format
(Code # 4)
Example:
Port 6
Code #
Connection Type
Connection
Type
2
Telnet:
3
or SSH:
SC-ADT
Port #
01 - 32
Auto-Config
Code #
1
2
3
4
5
0
Code # 0 disables auto-config; that is, the existing format of the ADT port is maintained.
7O1
Содержание SC-ADT 16 Por
Страница 6: ...iv SpectraCommADT 076R172 000 Installation and Operation Manual Issue 6 Table of Contents...
Страница 92: ...Additional Features SNMP Traps 5 24 SpectraCommADT 076R172 000 Installation and Operation Manual Issue 6...
Страница 105: ......
Страница 106: ...The Best Connections in the Business...