SC-ADT Configuration
Configuration Overview
076R172-000
SpectraComm ADT
3-3
Issue 6
Installation and Operation Manual
Configuring SC-ADT Craft Port
1. Ensure your workstation is equipped with communication software (i.e., Hyperterminal) for
making a VT-100 connection. Consult your PC’s operating system documentation for details.
2. For initial configuration of a SC-ADT, you must configure a VT100-compatible terminal for
the following settings:
9600,8,
N,1
3. Connect the terminal to the SC-ADT
CRAFT
(console) port using the proper DB25M to
RJ45adapter (GDC P/N 029H210-001) and a RJ45 to RJ45 straight-thru cable
(GDC 830-128-807, or similar).
4. Make a Hyperterminal connection to the
CRAFT
port.
5. Hit <
CR
> a few times or press
CTRL-R
. The following Welcome screen will appear, followed
by a command line prompt:
***************************************************************************
***************************************************************************
** **
** W E L C O M E T O S P E C T R A C O M M ADT 32 **
** **
** Copyright General DataComm 2009 **
** **
** Running version is V2.0.0 **
** **
** Use "?" at any time on the command line to get help. **
***************************************************************************
***************************************************************************
SC-ADT16>
Note
For online help screens describing all CLI options, press
?
Note that the CLI options for configuring the
SC-ADT are only available when you have enabled Supervisor or Admin privileges.
6. Enable supervisor privileges by typing:
enable
[supervisor-level password]
7. The SC-ADT is now operating in supervisor mode as shown by the
#
symbol in the new CLI
prompt, with all CLI options available, except user accounts.
8. You can now configure the SC-ADT to suit your network by typing the required configurations
commands at the CLI prompt. You do not need to set parameters that coincide with system
defaults. Any configuration changes will take affect immediately.
Note
FOR ADVANCED USERS: The SC-ADT provides a utility for generating the configuration settings of a
SC-ADT into an ASCII file, simplifying the configuration of multiple SC-ADT cards. This function can also
be used to archive configuration data for specific unit or as a baseline for modified configurations.
Refer to
Appendix A, Application Guidelines
.