3.2.2

 

Mounting the Indoor Unit (evaporator) 

 

The indoor unit needs to be installed upright on the 

interior wall of the cabin, away from direct sunlight or cross 
breeze; unit controls should be easily accessible by the end 
user,  unit  should  not  obstruct  walkways.  Adequate 
clearance  should  be  maintained  around  the  unit.  Special 
considerations should be made to allow condensate water 
to escape the unit without causing leaks. Please ensure the 
indoor unit is properly fastened. 

 

3.2.3

 

Installing Refrigerant Lines 

 

Inspect  provided  with  the  kit  refrigerant  lines  and 

end fittings for signs of damage before making connections. 
After connecting the lines, coil excess hose, if any, and secure 
hose  firmly to  prevent  friction  and  strain  tension.  Connect 
AC  manifold  gauge  to  the  valve  ports  located  inside  the 
outdoor unit and use vacuum pump to remove the air from 
refrigerant lines. Although the leak test has been completed 
at  the  factory,  it  is  recommended  (but  not  necessary)  to 
compete nitrogen leak test after the installation is complete. 
Alternatively,  you  could  leave  the  lines  overnight  to  make 
sure the vacuum is maintained within the lines. After test is 
complete  and  the  air  is  removed  from  the  lines 

  open 

manual valves to let refrigerant into the lines.  

 

 

 

Содержание 2600A

Страница 1: ......

Страница 2: ...iagram 6 2 2 Plumbing Diagram 7 3 INSTALLATION AND COMMISSIONING 8 3 1 Before the Install 8 3 2 Installation 10 3 2 1 Mounting the Outdoor Unit condenser 10 3 2 2 Mounting the Indoor Unit evaporator 1...

Страница 3: ...ng Lynx No idle DC split type air conditioner This service manual describes installation and operation procedures maintenance recommendations and troubleshooting tips Please read carefully before usin...

Страница 4: ...KIT 1 2 Areas of Application Lynx series split type air conditioner is designed for use in a wide variety of automotive applications such as utility vehicles ambulance armored vehicles construction v...

Страница 5: ...t rating A 50 38 Current draw A 25 70 10 45 Airflow m3 hr 250 300 Setpoint range 16 32 Refrigerant type 610 20g R 134a Working pressure 0 4 1 8 Mpa Compressor type 3 phase variable speed hermetic Comp...

Страница 6: ...the following features Variable speed compressor allows proportional cooling reducing noise and increasing efficiency Short cycling of compressor is no longer a concern Unit uses industry standard R...

Страница 7: ...info generalcomponents ca 1 800 517 7740 2 PRINCIPLE OF OPERATION 2 1 Electrical Diagram...

Страница 8: ...7 Lynx No Idle Split AC User Manual 2 2 Plumbing Diagram...

Страница 9: ...e factory tested for leaks and proven safe Every kit comes pre charged with refrigerant and contains all parts and hardware required for installation Evaporator assembly indoor unit Condenser assembly...

Страница 10: ...nd or in other ways modify factory provided refrigerant hoses Doing so will void the warranty and will cause equipment malfunctions Do not install refrigerant lines with signs of damage Do not attempt...

Страница 11: ...earance to prevent mechanical damage dust splashes of water Supporting walls should be strong enough to withstand equipment weight and provide adequate grip for the mounting screws Ease of access Unit...

Страница 12: ...11 Lynx No Idle Split AC User Manual...

Страница 13: ...es Inspect provided with the kit refrigerant lines and end fittings for signs of damage before making connections After connecting the lines coil excess hose if any and secure hose firmly to prevent f...

Страница 14: ...POE RB68EP oil should be used Please use only designated oil type Mixture of different brands of lubrication oil will form precipitates which will affect compressor lubrication 3 2 4 Wiring Install a...

Страница 15: ...ructions Look for abnormal noise vibration or smell Use manifold gauge to check refrigerant pressure throughout the cooling cycles of the unit Let the unit run continuously at full power for at least...

Страница 16: ...ecified voltage range Power supply cable is undersized Use proper gauge supply lines Incorrect temperature setting Set temperature Refrigerant leak in system Repair leak and add refrigerant Poor cooli...

Страница 17: ...y 8 Server reported data error 9 AT Incomplete instructions 10 Connection server error 11 Command sending error 12 Command sending is busy 13 Initializing network failed 14 Failed to read SIM card 15...

Страница 18: ...mal compressor shutdown 29 Over Input Voltage Protection Above 15 5V 30 Low Input Voltage Protection Below 11V 31 The evaporator temp is below freezing 32 Anti freezing Protection 33 Room Temperature...

Страница 19: ...anel on the unit itself When a button pressed on the remote the unit should beep once to acknowledge the command Use ON OFF power button to turn the unit on and off Use MODE button to switch between C...

Страница 20: ...19 Lynx No Idle Split AC User Manual The unit should not be used at temperatures below 5 41 or above 43 110...

Страница 21: ...nd fan from dust Clean evaporator condensate drain from clogs Inspect screws and bolts holding the units make sure they are tight Inspect wiring for frays Inspect refrigerant lines and insulation for...

Страница 22: ...21 Lynx No Idle Split AC User Manual 7 PARTS LIST...

Страница 23: ...info generalcomponents ca 1 800 517 7740...

Страница 24: ...23 Lynx No Idle Split AC User Manual...

Страница 25: ...info generalcomponents ca 1 800 517 7740...

Страница 26: ...25 Lynx No Idle Split AC User Manual...

Страница 27: ...info generalcomponents ca 1 800 517 7740...

Страница 28: ...27 Lynx No Idle Split AC User Manual 203 1515 Broadway St Port Coquitlam BC Canada V3C 6M2 1 800 517 7740 1 604 677 6210 info generalcomponents ca April 2020...

Отзывы: