Generac Power Systems PowerDial RS8000E Скачать руководство пользователя страница 14

12

Owner’s Manual for Portable Generator

Know Generator Limits

Overloading a generator can result in damage

to  the  generator  and  connected  electrical

devices.  Observe  the  following  to  prevent

overload:
• Add  up  the  total  wattage  of  all  electrical

devices to be connected at one time. This

total should NOT be greater than the gener-

ator's wattage capacity.

• The  rated  wattage  of  lights  can  be  taken

from light bulbs. The rated wattage of tools,

appliances, and motors can be found on a

data label or decal affixed to the device.

• If  the  appliance,  tool,  or  motor  does  not

give  wattage,  multiply  volts  times  ampere

rating  to  determine  watts  (volts  x  amps  =

watts).

• Some  electric  motors,  such  as  induction

types, require about three times more watts

of power for starting than for running. This

surge  of  power  lasts  only  a  few  seconds

when  starting  such  motors.  Make  sure  to

allow for high starting wattage when select-

ing electrical devices to connect to the gen-

erator:

1. Figure the watts needed to start the largest

motor.

2. Add  to  that  figure  the  running watts  of  all

other connected loads.

The Wattage Reference Guide is provided to

assist in determining how many items the gen-

erator can operate at one time.

NOTE: 

All figures are approximate. See data

label on appliance for wattage requirements.

Wattage Reference Guide

Transporting/Tipping of the Unit

Do  not  operate,  store  or  transport  the  unit  at

an angle greater than 15 degrees.

Device

Running 

Watts

*Air Conditioner (12,000 Btu)

1700

*Air Conditioner (24,000 Btu)

3800

*Air Conditioner (40,000 Btu)

6000

Battery Charger (20 Amp)

500

Belt Sander (3")

1000

Chain Saw

1200

Circular Saw (6-1/2")

800 to 1000

*Clothes Dryer (Electric)

5750

*Clothes Dryer (Gas)

700

*Clothes Washer

1150

Coffee Maker

1750

*Compressor (1 HP)

2000

*Compressor (3/4 HP)

1800

*Compressor (1/2 HP)

1400

Curling Iron

700

*Dehumidifier

650

Disc Sander (9")

1200

Edge Trimmer

500

Electric Blanket

400

Electric Nail Gun

1200

Electric Range (per element)

1500

Electric Skillet

1250

*Freezer

700

*Furnace Fan (3/5 HP)

875

*Garage Door Opener

500 to 750

Hair Dryer

1200

Hand Drill

250 to 1100

Hedge Trimmer

450

Impact Wrench

500

Iron

1200

*Jet Pump

800

Lawn Mower

1200

Light Bulb

100

Microwave Oven

700 to 1000

*Milk Cooler

1100

Oil Burner on Furnace

300

Oil Fired Space Heater (140,000 

Btu)

400

Oil Fired Space Heater (85,000 Btu)

225

Oil Fired Space Heater (30,000 Btu)

150

*Paint Sprayer, Airless (1/3 HP)

600

Paint Sprayer, Airless (hand-held)

150

Radio

50 to 200

*Refrigerator

700

Slow Cooker

200

*Submersible Pump (1-1/2 HP)

2800

*Submersible Pump (1 HP)

2000

*Submersible Pump (1/2 HP)

1500

*Sump Pump

800 to 1050

*Table Saw (10")

1750 to 2000

Television

200 to 500

Toaster

1000 to 1650

Weed Trimmer

500

* Allow 3 times the listed watts for starting these 

devices.

Содержание PowerDial RS8000E

Страница 1: ...RCHASED ______________ Register your Generac product at register generac com 1 888 922 8482 SAVE THIS MANUAL FOR FUTURE REFERENCE 000478 000209b WARNING Loss of life This product is not intended to be...

Страница 2: ...and Use Questions 11 Before Starting Engine 11 Prepare Generator for Use 11 Grounding the Generator When Used as a Portable 11 Know Generator Limits 12 Transporting Tipping of the Unit 12 Starting Pu...

Страница 3: ...d does not render the equipment unsafe Throughout this publication and on tags and decals affixed to the generator DANGER WARNING CAUTION and NOTE blocks are used to alert personnel to special instruc...

Страница 4: ...us injury WARNING 000250 WARNING Equipment and property damage Do not operate unit on uneven surfaces or areas of excessive moisture dirt dust or corrosive vapors Doing so could result in death seriou...

Страница 5: ...ric motors and generators for installation and use in accordance with the Rules of the Cana dian Electrical Code 7 ANSI PGMA G300 Safety and Perfor mance of Portable Generators Portable Generator Manu...

Страница 6: ...4 Owner s Manual for Portable Generator 0H8251B 0H4635C 5 FEET 1 5m MINIMUM FROM OBJECTS CARBON MONOXIDE CO READ MANUAL...

Страница 7: ...17 18 7 13 9 11 6 12 19 10 1 120 240 Volt AC 30 Amp Locking Receptacle NEMA L14 30R 2 Circuit Breakers AC 3 Hour Meter 4 Battery Charger Input 5 120 Volt AC 20 Amp GFCI Duplex Receptacle NEMA 5 20R 6...

Страница 8: ...rnate with elapsed time in hours and tenths The hours will flash four times then alternate with the maintenance message four times until the meter automatically resets 100 hours CHG OIL Oil Change Int...

Страница 9: ...t a suitable 4 wire grounded cord set to plug and desired load The cord set should be rated 250 Volts AC at 30 Amps or greater See Figure 2 6 Use this receptacle to operate 120 Volt AC 60 Hz single ph...

Страница 10: ...ad bolts L through rubber bumper D then through frame foot C 2 Slide hex head bolts K through holes in frame rail 3 Slide frame foot C onto hex head bolts K Install locking flange nuts J Install handl...

Страница 11: ...n fresh unleaded gasoline Minimum rating of 87 octane 87 AKI 91 RON Up to 10 ethanol gasohol is acceptable where available non ethanol premium fuel is recommended DO NOT use E85 DO NOT use a gas oil m...

Страница 12: ...from forming in fuel system parts such as the carburetor fuel hose or tank during storage Alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separation and fo...

Страница 13: ...m It is recommended to use a manual transfer switch when connecting directly to a building electrical system Connecting a portable gen erator to a building electrical system must be made in strict com...

Страница 14: ...e for wattage requirements Wattage Reference Guide Transporting Tipping of the Unit Do not operate store or transport the unit at an angle greater than 15 degrees Device Running Watts Air Conditioner...

Страница 15: ...arts release switch 3 See Figure 3 3 When engine starts rotate PowerDial to RUN Choke operation is reduced as PowerDial is rotated towards RUN If engine falters rotate PowerDial counterclockwise to ST...

Страница 16: ...n use for pro longed periods of time If the battery is unable to crank the engine plug in the 12V charger included in the accessory box RUNNING THE GENERATOR DOES NOT CHARGE THE BATTERY Use battery ch...

Страница 17: ...and unobstructed NOTE DO NOT use a garden hose to clean generator Water can enter engine fuel system and cause problems If water enters generator through cooling air slots some water will be retained...

Страница 18: ...nd oil drain plug 4 Remove oil fill cap 5 Remove oil drain plug and drain oil com pletely into a suitable container 6 Install oil drain plug and tighten securely 7 Slowly pour oil into oil fill openin...

Страница 19: ...iolation of California Public Resource Code Section 4442 to use or oper ate the engine on any forest covered brush covered or grass covered land unless the exhaust system is equipped with a spark arre...

Страница 20: ...stabilizer is added to fuel system pre pare and run engine for long term storage Run engine for 10 15 minutes to circulate sta bilizer throughout fuel system Adequately prepared fuel can be stored up...

Страница 21: ...Dirty air filter 3 Out of fuel 4 Stale fuel 5 Spark plug wire not connected to spark plug 6 Bad spark plug 7 Water in fuel 8 Overchoking 9 Low oil level 10 Excessive rich fuel mixture 11 Intake valve...

Страница 22: ...20 Owner s Manual for Portable Generator Notes...

Страница 23: ...Owner s Manual for Portable Generator 21...

Страница 24: ...rights reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45 W2929...