Generac Mobile Products LLC
l
800-926-9768
l
920-361-4442
l
www.generacmobileproducts.com
Page 1 of 3
MLT6SK
ENGINE
•
Kubota® D1005- liquid cooled, diesel engine; Final Tier 4
o
Standby - 13.1 hp @ 1800 rpm
o
Prime - 11.7 hp @ 1800 rpm
o
3 cylinder
o
1.0 L displacement
•
Polyethylene Fuel Tank:
o
Fuel Type: Diesel
o
Fuel Capacity: 39.9 gal (151.04 L)
o
External 3.5 in. (89 mm) fill port
•
Fuel Consumption:
o
Full load: 0.58 gph (2.18 Lph)*
o
Lights Only: 0.42 gph (1.60 Lph)*
o
Maximum Runtime (Lights Only): 95 hours*
•
Cooling system capable of operating at 120°F (49°C) ambient
•
1,000-hour service interval*
•
Full flow oil filter, spin on type
•
Dry type cartridge air filter
•
60 Hz engine/generator
•
Wind Rating: 65 mph (105 kph)
*Results based on engine manufacturer and field test data after 100-hour engine break-in period and may vary based on factors including age
and maintenance of equipment, environmental conditions and fuel density. Consult the Owner's Manual for fuel and maintenance
recommendations.
GENERATOR
•
Marathon Electric
®,
Brushless
•
Up to 6kW power output
•
120/240 VAC – 50/25A
•
+/-6% capacitor voltage regulation
ENGINE CONTROLS
•
External, illuminated control panel with sealed switches
•
Four position keyed switch – (off, run, glow start)
•
Digital hour meter
•
Automatic low oil pressure/high temperature shutdown system
ELECTRICAL SYSTEM
•
30A start trip breaker (assures no load condition exists before starting)
•
Individual floodlight circuits with sealed 15A breakers
•
Standard individually breakered convenience outlets:
o
(1) 120 VAC 20 Amp GFCI duplex outlet (NEMA 5-20R type)
o
(1) 240 VAC 30 Amp twist lock outlet (NEMA L6-30R type)
•
Wiring is sized and fused to the amperage draw required
•
440CCA wet cell battery
SPECIFICATIONS
METAL HALIDE LIGHT TOWER