Owner’s Manual for Mobile Generator

Introduction and Safety

General Hazards

Explosion and Fire Hazards

Asphyxiation. Running engines produce 
carbon monoxide, a colorless, odorless, 
poisonous gas. Carbon monoxide, if not 
avoided, will result in death or serious injury.

(000103)

DANGER

(000107)

WARNING

Hearing Loss. Hearing protection is 
recommended when using this machine. 
Failure to wear hearing protection could 
result in permanant hearing loss.

(000111)

WARNING

Moving Parts. Keep clothing, hair, and 
appendages away from moving parts. Failure 
to do so could result in death or serious injury.

(000108)

WARNING

Hot Surfaces. When operating machine, do not 
touch hot surfaces. Keep machine away from 
combustibles during use. Hot surfaces 
could result in severe burns or fire.

WARNING

In case of an emergency, press the
emergency stop button to stop the engine
immediately. Failure to do so could result
in death or serious injury.

(000298)

CAUTION

(000291)

Equipment damage. Do not attempt to start or operate 
a unit in need of repair or scheduled maintenance. 
Doing so could result in serious injury, death, or 
equipment failure or damage.

WARNING

WARNING

Risk of injury. Do not operate or service this 
machine if not fully alert. Fatigue can impair the 
ability to service this equipment and could result 
in death or serious injury.

(000215)

(000182)

WARNING

CAUTION

(000229)

Equipment or property damage. Do not block
air intake or restrict proper air flow. Doing so
could result in unsafe operation or damage
to unit.

(000105)

DANGER

Explosion and Fire. Fuel and vapors are 
extremely flammable and explosive. Add fuel 
in a well ventilated area. Keep fire and spark 
away. Failure to do so will result in death 
or serious injury.

 

WARNING

Fire risk. Fuel and vapors are extremely 
flammable. Do not operate indoors. Doing so 
could result in death, serious injury, or 
property or equipment damage.

(000281)

(000147)

WARNING

Risk of Fire. Unit must be positioned in a
manner that prevents combustible material
accumulation underneath. Failure to do so
could result in death or serious injury.

Содержание MAGNUM MLG15M

Страница 1: ...ur Generac product at WWW GENERAC COM 1 888 GENERAC 1 888 436 3722 MODEL NUMBER _________________________ SERIAL NUMBER _________________________ DATE PURCHASED ________________________ Owner s Manual...

Страница 2: ...nd some of its constituents are known to the state of California to cause cancer birth defects and other reproductive harm 000005 WARNING California Proposition 65 This product contains or emits chemi...

Страница 3: ...tch 10 Automatic Shutdown 10 Voltage Regulator 11 Derating for Altitude 11 Wet Stacking 11 Receptacle Panel 11 Shutting Down the Unit 11 Towing the Unit 11 Lifting the Unit 12 Maintenance Emissions In...

Страница 4: ...iv Owner s Manual for Mobile Generator This page intentionally left blank...

Страница 5: ...he warnings in this manual and on tags and decals affixed to the unit are therefore not all inclusive If using a procedure work method or operating technique that the manufacturer does not specificall...

Страница 6: ...CAUTION 000291 Equipment damage Do not attempt to start or operate a unit in need of repair or scheduled maintenance Doing so could result in serious injury death or equipment failure or damage WARNI...

Страница 7: ...onductor Apply first aid and get medical help Failure to do so will result in death or serious injury 000104 DANGER Electrocution Water contact with a power source if not avoided will result in death...

Страница 8: ...us injury 000137a WARNING 000162 WARNING Explosion Do not dispose of batteries in a fire Batteries are explosive Electrolyte solution can cause burns and blindness If electrolyte contacts skin or eyes...

Страница 9: ...onent Locations Table 2 1 Generator Components A Fuel Filler Location under door E Receptacle Panel not available on MLG8 units B Radiator Access Panel F Ground Studs 2 C Control Panel Locations under...

Страница 10: ...gh quality detergent oil with an appropriate classification and viscosity for the engine type and ambient temperature conditions Consult your Generac Mobile Products Authorized Dealer or the applicabl...

Страница 11: ...120VAC 120VAC 120VAC 240VAC 240VAC TURN TURN MAIN MAIN BREAKER BREAKER OFF OFF 120VAC 120VAC BREAKER BREAKER 120VAC 120VAC BREAKER BREAKER 240VAC 240VAC MAIN CIRCUIT MAIN CIRCUIT BREAKER BREAKER 240VA...

Страница 12: ...8 Owner s Manual for Mobile Generator General Information This page intentionally left blank...

Страница 13: ...ris Verify all covers are in place and secure Verify the emergency stop switch is pulled out Starting the Unit NOTE If the engine was run out of fuel or the fuel tank was drained it may be necessary t...

Страница 14: ...closed and locked Figure 3 4 Emergency Stop Switch Activate the emergency stop switch by pushing the button in until it locks down This will trip the main circuit breaker which will open the contact d...

Страница 15: ...it breaker is switched to ON I Each receptacle has an individual circuit breaker located inside the cabinet under a flip up cover Each circuit breaker corresponds with the receptacle located below it...

Страница 16: ...capacity For approximate weights see the applicable product spec sheet 2 Always remain aware of people and objects around the unit while moving 3 Use the forklift pockets with care Approach the unit...

Страница 17: ...roughly before starting Inspect condition of electrical cords Do not use the unit if insulation is cut or worn through Verify the condition of the air filter by viewing the level of the vacuum draw on...

Страница 18: ...nspect Replace Air Filter Replace Engine Oil Check Radiator and Hose Clamps Replace Engine Oil Filter Replace Fuel Filter Clean Water Separator Replace Fan Belt Check Clean Battery Inspect Adjust Valv...

Страница 19: ...asic Maintenance Schedule MLG20 Item As Required Every 250 Hours Every 500 Hours Every 1000 Hours Every 12 Months Drain Water Separator Check Coolant Level Inspect Belt Replace Engine Oil Replace Engi...

Страница 20: ...htweight oil Top Wind Models Apply a lightweight oil to the screw stem Figure 4 1 Lubrication Points Trailer Wheel Bearings The trailer axles are equipped with a grease fitting to allow lubrication of...

Страница 21: ...is usually sufficient for proper engine starting The unit must be level to maintain proper orientation of the heater while it is in operation Use only an undamaged outdoor rated three prong grounded...

Страница 22: ...18 Owner s Manual for Mobile Generator Maintenance This page intentionally left blank...

Страница 23: ...RECEPTACLE TWIST LOCK 30 AMP RECEPTACLE TWIST LOCK 50 AMP RECEPTACLE TWIST LOCK 50 AMP WHT WHT WHT WHT GRN GRN GRN GRN GRN GRN WHT RED RED WHT BLK BLK BREAKER CIRCUIT 30 AMP 30 AMP CIRCUIT BREAKER 50...

Страница 24: ...PTACLE 240 VOLT 30 AMP TWIST LOCK RECEPTACLE 90318_ORG_07 06 11 240 VOLT 30 AMP TWIST LOCK RECEPTACLE 20 AMP CIRCUIT BREAKER 20 AMP CIRCUIT BREAKER 20 AMP G F I OUTLET 20 AMP G F I OUTLET 30 AMP CIRCU...

Страница 25: ...25 16 20 AMP CIRUIT BREAKER CB GRN 20 AMP G F I OUTLET 240 VOLT 30 AMP TWIST LOCK RECEPTACLE 240 VOLT 30 AMP CIRCUIT BREAKER 20 AMP CIRUIT BREAKER GRN CB 20 AMP G F I OUTLET GRN YEL WHT WHT WHT RED R...

Страница 26: ..._A_07 25 16 20 AMP CIRUIT BREAKER CB GRN 20 AMP G F I OUTLET 240 VOLT 30 AMP TWIST LOCK RECEPTACLE 240 VOLT 30 AMP CIRCUIT BREAKER 20 AMP CIRUIT BREAKER GRN CB 20 AMP G F I OUTLET GRN YEL WHT WHT WHT...

Страница 27: ...NOID RED HOLD WHT PULL BLK COM ORN BRN BLK CONTROL RESISTANCE BLU BLU DOME LIGHT R1 R2 B BR ACC C STARTER SWITCH GRN BLU RED GRN RED BLK B B S STARTER RED BATTERY 12V EMERGENCY STOP SWITCH 1 4 3 2 N C...

Страница 28: ...AMBER TRAILER PLUG RIGHT TAIL TURN LAMP LAMP PLATE LICENSE MARKER LAMP RED BK BK BK BK RD WT BK SPLICE SPLICE SPADE SPADE LAMP TAIL TURN LEFT RD WT BK SPADE YL BN WT SPADE SPADE WT BK BN WT SPLICE GN...

Страница 29: ...______________________________________________ __________________________________________________________________________________________ ______________________________________________________________...

Страница 30: ...26 Owner s Manual for Mobile Generator Wiring Diagrams and Service Log This page intentionally left blank...

Страница 31: ......

Страница 32: ...ts reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Mobile Products LLC Generac Mobile Products 215 Power Dri...

Отзывы: