background image

GENERAC POWER SYSTEMS, INC.

P.O. BOX 297 • WHITEWATER, WI 53190

www.generac.com

Part#D5507

PLEASE NOTE:  

This installation guide is not a substitute for the

Installation and Owner’s Manual” that will be furnished

with the Guardian

®

Home Standby Generator or the

Owner’s Manual” furnished with the Guardian

®

Ultra

Source Portable Generator you may purchase in the
future. Please review the installation procedure again at
the time of generator installation. This kit is not intended
for use with the Guardian

®

Liquid-Cooled Generator

product line. This kit is not suggested to be compatible
with other generator manufacturer’s products. 

Содержание 1276-1

Страница 1: ...the Guardian Home Standby Generator or the Owner s Manual furnished with the Guardian Ultra Source Portable Generator you may purchase in the future Please review the installation procedure again at t...

Страница 2: ...Generator for emergency power now Later install your Standby for automatic emergency power 100 AMP automatic transfer switch with built in load center 30ft and 2ft pre wired conduits 5ft power cord an...

Страница 3: ...INSTALLATION DRAWING AUTOMATIC TRANSFER SWITCH CONNECTED TO THE EXTERNAL CONNECTION BOX Installation Guide...

Страница 4: ...y possible circumstance that might involve a hazard The warnings in this manual and on tags and decals affixed to the unit are therefore not all inclusive If you use a procedure work method or operati...

Страница 5: ...N TO THE HOME S MAIN DISTRIBUTION PANEL 12 UL LISTED WIRE NUTS not shown TOOLS REQUIRED Drill drill bits hole saw type and length will be determined by the materials you will be drilling and cutting o...

Страница 6: ...Let the engine run for a minute or two at no load to stabilize the internal temperatures 3 Turn off the generator 4 Turn OFF the utility power supply to the transfer switch using the means provided s...

Страница 7: ...of main distribution panel The automatic transfer switch can be located to the left or right of main distribution panel Hold transfer switch against the mounting surface Level the transfer switch and...

Страница 8: ...f a power failure Wire nut the black wire to the matching circuit lead wire from the emergency circuit breaker from load center in the transfer switch All circuit wires are color coded and labeled for...

Страница 9: ...on to enter beyond the clamp to the inside of the box TIghten clamp securely Attach ground wire green to the bottom of the box using the supplied ground screw and pre drilled hole Connect red black an...

Страница 10: ...and length of the generator mounting pad 48 L x 24 W 3 Lay black poly film to cover the area 4 Fill the area to ground level with pea gravel or crushed stone 5 Drive an 8 foot grounding rod into the g...

Отзывы: