![Generac Mobile G4-ECO Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/generac-mobile/g4-eco/g4-eco_owners-manual_2208807029.webp)
Owner’s Manual for G4-ECO Light Tower
25
Operation
Start Procedure
1. Turn Utility/Off/Generator selector on control panel
to the desired power source. See
for location.
•
Generator powers the light tower using the unit
generator/engine.
•
Utility powers the light tower using the power
source connected to the control panel power inlet.
See
for more
information.
NOTE:
When using utility power, the mains utility voltage
and frequency are displayed on the controller screen,
and all engine icons, inputs, alarms, and procedures are
disabled.
2. Turn ON main circuit breaker and mast light
breakers.
3. Use the controller Manual/Auto button to select the
desired mode.
•
Manual mode is the system default. In Manual
mode, the user manually turns the light tower ON
and OFF. When Manual mode is selected the
Manual mode icon will appear on the controller
screen:
.
•
Automatic mode automates light tower control
based on presets. The Light Sensor preset turns
the unit ON/OFF when ambient light reaches a
threshold. The Timer preset turns the unit ON/OFF
based at a user-defined time. When Automatic
mode is selected, the default Manual mode icon
will be replaced by Automatic mode icons:
for Light sensor, and
and
for more
information.
4. Press the controller Start/Stop button to start the
engine.
NOTE:
During startup, the unit will perform a series of
routine system checks before the light tower can be
used. The controller indicates the light tower is ready for
use when the engine icon
stops blinking and turns
solid.
5. Use the controller Lamps 1-4 On/Off buttons to
switch the desired lamps ON.
NOTE:
The lamps do not turn ON simultaneously. There
is a delay between lights. The status LED above the lamp
switch will blink during this delay, and stop blinking when
the lamp switches ON.
Lowering the Mast
WARNING
Personal Injury. Stop immediately if the mast hangs
up or the winch cable develops slack. Excess slack
could cause the mast to collapse, resulting in personal
injury or equipment damage.
(000265)
1. Shut off lights.
2. Use winch handle to lower the mast to its lowest
position. Verify the electrical cord does not get
caught in, or pinched by, the mast while it is being
lowered.
IMPORTANT NOTE:
Contract a Generac Mobil Product
Authorized Dealer immediately if the mast hangs up or
the winch cable develops slack.
Customer Convenience
Receptacles
See
. The unit is equipped with convenience
outlets for powering accessories or tools. Power is
supplied to the outlets any time the engine is running.
Each outlet has an individual circuit breaker, located on
the control panel.
The circuit breakers are labeled with the corresponding
voltage for the receptacle they protect. The standard
receptacle panel is equipped with the following
receptacles:
•
One 120/240VAC-20A L14-20R (A)
•
Two 120VAC-15A GFCI receptacle (5-15R) (B)
With all of the lights OFF, full generator power output is
available to the receptacles.
NOTE:
See
for recommended cable size and
length.
A
B
Figure 3-9. Customer Convenience Receptacles
Содержание G4-ECO
Страница 16: ...27 010832 Introduction and Safety 12 Owner s Manual for G4 ECO Light Tower Figure 1 5 Decal Locations 5 of 5 ...
Страница 32: ...28 Owner s Manual for G4 ECO Light Tower Operation This page intentionally left blank ...
Страница 39: ...Owner s Manual for G4 ECO Light Tower 35 Section 6 Wiring Diagrams AC Schematic ...
Страница 40: ...36 Owner s Manual for G4 ECO Light Tower Wiring Diagrams GTL04 Controller ...
Страница 41: ...Owner s Manual for G4 ECO Light Tower 37 Wiring Diagrams DC Schematic ...
Страница 42: ...38 Owner s Manual for G4 ECO Light Tower Wiring Diagrams LED Light Wiring ...
Страница 43: ......