Genelec Loudspeaker Manager (GLM) 2.0 - System Operating Manual
page 38 of 55
Table 10. Group settings for SE7261 with digital audio input
Setting
Description
View
Subwoofer Name
Name tag to help identify subwoofer
In Group
When this setting is ON the subwoofer belongs to
the current group. When the setting is OFF the
monitor is not in the group and does not play audio.
AES/EBU Digital
Channel
These controls select the subframes that the
subwoofer reproduces. Subframes of input 1 are on
the first row, subframes of input 2 are on the
second, and so on.
LFE Channel
This control selects the subframe in input 4 for the
input of the LFE channel.
LFE Channel Gain The LFE can be b10dB, when this boost is
not done in the audio source.
Bass Management
filter (frequency)
This subwoofer applies the bass management
crossover frequency (global) or a customized
crossover frequency (individual).
When ‘Bass Management Bypass’ is active,
subwoofer frequencies are reproduced by the
monitors.
Bass Management
setting is
(individual or
global)
When ‘global’ is selected all monitors and
subwoofers follow the same settings for bass
management. This is the default setting and the
normal method of using bass management.
When ‘individual’ is selected, every monitor and
subwoofer can be individually set to the desired
bass management settings. These settings can be
different for every monitor and subwoofer. This is
only recommended for special acoustic
requirements and is not typically used.
Pass Through
Mode
The ‘Pass Through Mode’ setting defaults to ON for
compatibility with SAM systems.
You can force the subwoofer AES/EBU outputs to
be high-pass filtered by setting ‘Pass Through
Mode’ to OFF.