background image

front baffle and the cloth.The reflex port of 
the loudspeaker cabinet is located on the left 
side of the cabinet (see Figure 1). The airflow 
from the port must not be obstructed, and a 
free space of at least 5 cm (2") is required 
before the port.

Connections

Each  loudspeaker  is  delivered  with  two 
Speakon  cable  connectors.  There  is  one 
Speakon  output  on  the  amplifier  and  two 
Speakon cable inputs (one on each side) on 
the cabinet. Use only one input at any time. 
The inputs may not be used for daisy-chain-
ing several loudspeakers or connecting two 
amplifiers to a single loudspeaker.

Measure the required length of cable and 

solder the connectors on it. Pins 1- and 1+ 
carry the signal for the tweeter, pins 2- and 
2+ for the mid range driver and pins 3- and 3+ 
for the woofer. Pins 4- and 4+ are not used. 
See Table 1 below for recommended cable 
thicknesses. The  whole  cable  should  have 
an outside diameter of 8 to 20 mm (5/16" to 

13/16") to fit in the Speakon connector.

Alternatively,  pre-terminated  lengths  of 

cable are available from Genelec.

Be sure not to mix the amplifier/loudspeaker 

pairs  when  installing  multiple  loudspeakers 
at  the  same  time.  Each  amplifier  and  loud-
speaker delivered in the same box are marked 
with the same identification number and cali-
brated together for optimal performance.

Sufficient  cooling  for  the  amplifier  must 

be ensured. Leave at least ten centimeters 
(4 inches) free space above and below the 
amplifier to ensure cooling. The space adja-
cent to the amplifier must either be ventilated 
or sufficiently large to dissipate heat so that 
the ambient temperature does not rise above 
35 degrees Celsius (95°F).

There are no fans in the amplifier unit so 

it may be mounted in the listening room near 
the lodspeaker cabinet using a short cable.

Before connecting up, ensure that the mains 

switch  is  off.  Check  that  the  mains  voltage 
selector is correctly set to your local voltage. 
Audio input is made via a 10kOhm balanced 
XLR connector, but unbalanced leads may be 
used as long as pin 3 is grounded to pin 1 of 
the XLR. Once connection has been made, the 
loudspeakers are ready to be powered-up. 

Setting the input sensitivity

Adjustment of the input sensitivity of each 
loudspeaker  can  be  made  to  match  the 

output of the decoder or other source, by use 
of the input sensitivity control on the amplifier 
panel. A small screwdriver is needed for the 
adjustment. The  manufacturer  default  set-
ting for this control is -6 dBu (fully clockwise) 
which gives an SPL of 100 dB @1m with a 
-6 dBu input level. To get the full output level 
from the AOW312 an input level of +10 dBu 
is needed at this setting. 

Autostart and remote control

The AOW312 is equipped with an “Autostart” 
function,  which  automatically  turns  the 
amplifier to “standby” mode if an input signal 
has  not  been  detected  for  approximately 
thirty minutes, and back to “on” mode when 
the  signal  returns.  The  function  can  be 
deactivated by turning the “AUTOSTART” 
dip switch to “OFF”. A two-colour LED on 
the  amplifier  panel  indicates  the  ampli-
fier  status:  green  for  “on”  and  yellow  for 
“standby”. 

The amplifier mode can also be switched 

by  a  remote  control  unit  connected  to  the 
respective inputs on the amplifier. Two pairs 
of  connectors  are  provided,  1  and  2  for  a  
12 V DC type remote control, and 3 and 4 for 
an external switch or relay type control. Do 
not connect two remote controls to the loud-
speaker at the same time. Activate the func-
tion by turning the "REMOTE CONTROL" dip 
switch on the amplifier panel to "ON". Note 

Figure 2. Amplifier panel layout of the AOW312.

-1

-2

-3

-4 dB

-5

-6

MUTE

SERIAL

NUMBER

WARNING

NEVER OPERATE THIS EQUIPMENT WITHOUT A PROPER

EARTHED MAINS CONNECTION.

IT IS FORBIDDEN TO UNDO ANY SCREWS ON THIS EQUIPMENT.

SERVICING AND ADJUSTMENT MUST ONLY BE CARRIED OUT

BY QUALIFIED SERVICE PERSONNEL.

DO NOT EXPOSE TO WATER OR MOISTURE.

THIS EQUIPMENT IS CAPABLE OF PRODUCING SOUND

PRESSURE LEVELS IN EXCESS OF 85dB WHICH MAY CAUSE

PERMANENT HEARING DAMAGE.

ENSURE THAT THE CORRECT VOLTAGE IS SELECTED BEFORE

CONNECTING TO THE MAINS SUPPLY.

ELECTRIC SHOCK HAZARD!

MAINS INPUT

50 / 60 Hz

300 Watts

115 / 230 V

ON

˜

PIN 1 = GROUND

PIN 2 = + INPUT

PIN 3 = - INPUT

MAINS

VOLTAGE

SELECTOR

2

3

20Hz

100Hz

20Hz

250Hz

-8

INPUT SENSITIVITY

REQUIRED FOR

100dB SPL@1m.

REFER TO

OPERATING MANUAL

FOR MAXIMUM SPL.

SIGNAL INPUT

INPUT SENSITIVITY

-6

1

dBu

+6

+2

+4

-4

-2

0

BASS

TILT

BASS

ROLL-OFF

-2

-4 dB

-6

-8

OFF

ON

-2

-4 dB

-6

-8

OFF

ON

-2

0

-6

-4

ALL OFF

dB

-2

-8

-6

-4

0

dB

ALL OFF

CAL POSITION

ALL TONE CONTROLS : OFF

INPUT SENSITIVITY : -6dBu

20Hz

400Hz

3kHz

20kHz

FOR A FLAT FREE FIELD RESPONSE SET ALL

TONE CONTROLS TO OFF.

FOR ACCURATE OPERATION ONLY ONE

SWITCH IN EACH TONE CONTROL GROUP

SHOULD BE ON AT A TIME.

REFER TO THE OPERATING MANUAL FOR

SUGGESTED TONE CONTROL SETTINGS.

BASS

LEVEL

-1

-2

-3

-4 dB

-5

-6

MUTE

OFF

ON

0

-1

-2

-3

-4

-5

-6

dB

BASS

TREBLE

LEVEL

MID

LEVEL

OFF

ON

-1

-2

-3

-4 dB

-5

-6

MUTE

OFF

ON

TREBLE

MID

LEVEL CONTROLS

USING THE TONE CONTROLS

MADE IN FINLAND

www.genelec.com

MAGNETICALLY SHIELDED

GND

EXTERNAL

SWITCH

OR RELAY

12 V DC

REMOTE

2

3

4

1

+

REMOTE CTRL

AUTOSTART

POWER LED

STANDBY LED

REMOTE

CONTROL

OFF

ON

DO NOT USE BOTH

REMOTE CONTROL

TYPES AT THE

SAME TIME.

SWITCH THE REMOTE

CONTROL DIP SWITCH

ON WHEN USING

REMOTE CONTROL.

REMOTE CONTROL

OVERRIDES

AUTOSTART FUNCTION.

AUTOSTART SETS

THE AMPLIFIER TO

STANDBY MODE

WHEN THERE

IS NO SIGNAL.

CONNECTOR

PIN NO.

3

EXTERNAL SWITCH

4

OR RELAY

REMOTE CONTROL

TYPE

1 +

2 GND 12 V DC REMOTE

PIN 1 HIGH: ON

PIN 1 LOW: STANDBY

AMPLIFIER MODE

CONTACT CLOSED: ON

CONTACT OPEN: STANDBY

HT312A ACTIVE HOME THEATER SYSTEM

ON

TREBLE,MIDRANGE

AND BASS LEVEL

SWITCHES

BASS TILT AND

ROLL-OFF

SWITCHES

INPUT

SENSITIVITY

ADJUSTMENT

SIGNAL INPUT

CONNECTOR

MAINS VOLTAGE

SELECTOR, MAINS

CONNECTOR

AND SWITCH

REMOTE CONTROL

AND INDICATOR LED

SWITCHES

REMOTE CONTROL

CONNECTORS

400 (15 3/4")

220 (8 21/32")

47 (1 27/32")

1652 (65 1/32")

1672 (65 13/32")

1500 (59 1/16")

1360 (53 17/32")

ACOUSTIC

AXIS

181 (7 1/8")

175 (6 7/8")

246 (9 11/16")

15

°

Figure 1. Cabinet dimensions of the AOW312. The acoustic 
axis is located at the indicated height on the centerline of the 
loudspeaker cabinet.

Figure 3. AOW312 loudspeaker 
cabinet top view.

Figure 4. AOW312 loudspeaker 
cabinet top view at 15° angle.

Cable gauge

Max. length

2,0 mm

2

 (14 AWG)

30 m (100 ft)

3,3 mm

2

 (12 AWG)

40 m (130 ft)

5,3 mm

2

 (10 AWG)

60 m (200 ft)

Table 1. Recommended cable thicknesses for 
different lengths of cable

Содержание AOW312

Страница 1: ...Genelec AOW312 Active On Wall Loudspeaker Operating Manual AOW312 ...

Страница 2: ...d to an extent impossible with a pas sive system Variable input sensitivity as well as XLR line level input connectors provide easy connection and accurate level match ing to the preamplifier or surround decoder The bass midrange and treble amplifiers of the AOW312 produce 180 W for the low fre quency driver and 120 W each for the mid range and HF drivers The amplifiers are designed to operate at ...

Страница 3: ...e amplifier mode can also be switched by a remote control unit connected to the respective inputs on the amplifier Two pairs of connectors are provided 1 and 2 for a 12 V DC type remote control and 3 and 4 for an external switch or relay type control Do not connect two remote controls to the loud speaker at the same time Activate the func tion by turning the REMOTE CONTROL dip switch on the amplif...

Страница 4: ...und pressure levels in excess of 85 dB which may cause permanent hearing damage 4 A free flow of air around the amplifier is necessary to maintain sufficient cooling Do not obstruct airflow around the amplifier 5 To prevent fire or electric shock do not expose the unit to water or moisture Do not place any objects filled with liquid such as vases on or near the loudspeaker or the amplifier 6 Note ...

Страница 5: ...ONTROLS TO OFF FOR ACCURATE OPERATION ONLY ONE SWITCH IN EACH TONE CONTROL GROUP SHOULD BE ON AT A TIME REFER TO THE OPERATING MANUAL FOR SUGGESTED TONE CONTROL SETTINGS BASS LEVEL 1 2 3 4 dB 5 6 MUTE O FF ON 0 1 2 3 4 5 6 dB BASS TREBLE LEVEL MID LEVEL O FF ON 1 2 3 4 dB 5 6 MUTE O FF ON TREBLE MID LEVEL CONTROLS USING THE TONE CONTROLS MADE IN FINLAND www g en elec com MAGNE TICA LLY SHIE LDED G...

Страница 6: ...R female pin 1 gnd pin 2 pin 3 Input impedance 10 kOhm Input level for 100 dB SPL output 1m variable from 6 to 6 dBu Input level for maximum short term output variable from 22 to 10 dBu for 116 dB SPL 1m Subsonic filter 18 dB octave below 35 Hz Ultrasonic filter 12 dB octave above 25 kHz Crossover frequency Bass Mid Mid Treble 420 Hz 3 2 kHz Crossover acoustical slopes 18 24 dB octave Crossover le...

Отзывы: