AMPLIFIER SECTION 

Bass amplifier output power with an 8 Ohm load:   40 W
Treble amplifier output power with an 8 Ohm load:  40 W

Long term output power is limited by driver unit protection 
circuitry.
_____________________________________________ 
Amplifier system distortion at nominal output: 
THD 

< 0.08 % 

SMPTE-IM 

< 0.08 % 

CCIF-IM 

< 0.08 % 

DIM 100 

< 0.08 %

_____________________________________________ 
Signal to Noise ratio, referred to full output: 

 

Bass 

> 100 dB   

Treble 

> 100 dB

_____________________________________________ 
Mains voltage: 

100, 120, 220 or 230 V  

 

according to region

Voltage operating range: 

±10 %

Power consumption: 

 

Idle  

10 W

Standby 

<0,5 W   

Full output 

80 W

SYSTEM SPECIFICATIONS 

Lower cut-off frequency, –3 dB: 

< 55 Hz

_____________________________________________
Upper cut-off frequency, –3 dB: 

> 21 kHz

_____________________________________________
Free field frequency response of system: 
 

58 Hz – 20 kHz (± 2.0 dB)

_____________________________________________
Maximum short term sine wave acoustic output on axis in 
half space, averaged from 100 Hz to 3 kHz:
 

@ 1 m > 100 dB SPL

 

@ 0.5 m > 106 dB SPL

_____________________________________________
Maximum long term RMS acoustic output in same 
conditions with IEC weighted noise (limited by driver unit 
protection circuit): 

@ 1 m >  97 dB SPL

_____________________________________________
Maximum peak acoustic output per pair @ 1 m distance 
with music material: 

> 108 dB

_____________________________________________
Self generated noise level in free field @ 1m on axis:
 

< 10 dB (A-weighted)

_____________________________________________
Harmonic distortion at 85 dB SPL @ 1m on axis:
Freq: 

50…100 Hz <   2 % 

 

>100 Hz < 0.5 %

_____________________________________________
Drivers: Bass   

130 mm (5") cone 

 

Treble  

19 mm (

3

/

4

") metal dome 

Both drivers are magnetically shielded
_____________________________________________
Weight: 

5.5 kg (12.1 lb)

_____________________________________________
Dimensions:  
Height 

285 mm (11

1

/

4

”)

Width 

189 mm (7

7

/

16

")

Depth 

118 mm (7

1

/

16

”) 

CROSSOVER SECTION 

Input connector:  

Balanced 10 kOhm

 _____________________________________________
 
Input level for 100 dB SPL output at 1 m: 
 

-6 dBu at level control max 

_____________________________________________
 
Level control range:  

-40 dB relative to max output 

_____________________________________________
 
Crossover frequency, Bass/Treble: 

3.0 kHz 

_____________________________________________

Treble Tilt control operating range:  

 

 

0 to –2 dB @ 15 kHz

_____________________________________________

Bass Roll-Off control operating in a –6 dB step @ 85 Hz  
_____________________________________________

Bass Tilt control operating range in –2 dB steps:  

 

 

0 to –6 dB @ 100 Hz 

_____________________________________________

The ‘CAL’ position is with all tone controls set to ‘off’ and  
the level control to maximum (fully clockwise).

Содержание 4030B

Страница 1: ...4030B Operating Manual ...

Страница 2: ... the line of the acoustic axis The axis should be pointed towards the center of the listening area Connections Before connecting up ensure that the loudspeakers and the signal source have been switched off The power switch of the 4030B is located on the back panel see Figure 3 Connect the loudspeaker to an earthed mains connection with the supplied mains cable Never connect the loudspeaker to an u...

Страница 3: ...rol on the rear panel Setting the tone controls The frequency response of the Genelec 4030B can be adjusted to match the acoustic environ ment by setting the tone control switches on the rear panel The controls are Treble Tilt Bass Tilt and Bass Roll Off An acoustic measuring system such as WinMLS or comparable is recom mended for analyzing the effects of the adjust ments however careful listening...

Страница 4: ...the listening area Only vertical placement is pre ferred as it minimises acoustical cancellation prob lems around the crossover frequency Minimise reflections Acoustic reflections from objects close to the loudspeakers like walls cabinets etc can cause unwanted colouration blurring of the sound im age These can be minimised by placing the loud speaker clear of reflective surfaces Minimum clearance...

Страница 5: ...connected from the AC mains service unless the mains power cord is removed from the amplifier or the mains outlet Guarantee This product is guaranteed for a period of two years against faults in materials or workmanship Refer to supplier for full sales and guarantee terms Compliance to FCC rules This device complies with part 15 of the FCC Rules Operation is subject to the following conditions Thi...

Страница 6: ...ontal directiv ity characteristics of the 4030B measured at 1 m The lower curve shows the system s power response 80 85 90 95 d B r A 30 20k 50 100 200 500 1k 2k 5k 10k Hz Genelec Oy 4030 dBr vs freq Hz 7 Nov 2012 80 85 90 75 BASS ROLL OFF TREBLE TILT BASS TILT Figure 4 The curves show the effect of the Bass Tilt Treble Tilt and Bass Roll Off controls on the free field response of the 4030B ...

Страница 7: ...___________________________ Maximum peak acoustic output per pair 1 m distance with music material 108 dB _____________________________________________ Self generated noise level in free field 1m on axis 10 dB A weighted _____________________________________________ Harmonic distortion at 85 dB SPL 1m on axis Freq 50 100 Hz 2 100 Hz 0 5 _____________________________________________ Drivers Bass 13...

Страница 8: ... In Sweden Genelec Sverige Ellipsvägen 10B P O Box 5521 S 141 05 Huddinge Phone 46 8 449 5220 Fax 46 8 708 7071 Email info genelec com In the USA Genelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China Beijing Genelec Audio Co Ltd Jianwai SOHO Tower 12 Room 2605 D 1504 Chaoyang District Beijing 100022 China Phone 86 10 8580 2180 ...

Отзывы: