background image

 
 

GEMS SENSORS & CONTROLS 

 

OPERATING & INSTALLATION INSTRUCTIONS 

SERIES 2200/2600 

 

PLEASE READ CAREFULLY BEFORE INSTALLING

 

  

Part Number:   

560550-0064                                             

Issue:

   F 

 
 
 

INTRODUCTION 

 

The Series 2200/2600 pressure transducers use molecularly bonded high output strain gauges to 
provide 100mV output for full range pressure, when used with a 10V d.c. power supply. 
 
Series 2200/2600 high output pressure transducers and transmitters are fitted with an Asic 
providing various optional (at time of order) voltage outputs, and a 4-20mA current output 
capable of being used in control and indicating loops without further amplification. 
 
Series 2200/2600 with the CE Mark conform with the essential protection requirements of the 
EMC Directive 2004/108/EC amended by certified  type  testing  to  EN  61326-1  and                    
EN 61326-2-3. 

 

Series 2200/2600 with the CE0086 mark also complies with the requirements of the Pressure 
Equipment Safety Regulations 2016 and can be used as part of a safety-related system on 
Category IV pressure equipment. 
 

 

HAZARDOUS PRODUCTS

 

 

The Consumer Protection Act of 1987, Section 6 of the Health and Safety at Work Act 1974 and 
the Control of Substances Hazardous to Health Regulations 1988 require that we advise 
recipients and users of our products of any potential hazards associated with their storage, 
handling or use. 

 

The products which our Company supplies may be classified as Electrical, Electro-Mechanical 
and Electronic equipment. 

 

These products are tested and supplied in accordance with our published specifications or 
individual special requirements that are agreed in writing at time of order.  They are constructed 
so as not to affect adversely the safety of persons and property when properly installed, 
maintained and used by qualified personnel, in the applications for which they were designed and 
manufactured. 

 

Conformity with the requirements of the CE mark only applies when the installation 
conditions described in these instructions have been met.  For units supplied without a 
cable assembly connection to the transducer must be accomplished using Gems Sensors 
approved cable.  See APPROVED CABLE section.   

 
 
 
 
560550-0064 

    Issue 

   Page 

of 

 

Содержание 2200 Series

Страница 1: ...Category IV pressure equipment HAZARDOUS PRODUCTS The Consumer Protection Act of 1987 Section 6 of the Health and Safety at Work Act 1974 and the Control of Substances Hazardous to Health Regulations 1988 require that we advise recipients and users of our products of any potential hazards associated with their storage handling or use The products which our Company supplies may be classified as Ele...

Страница 2: ...xagon provided to apply a maximum torque of 15 8Nm The Customer must ensure that the pressure seal is suitable for the application If in doubt contact Gems Sensors ELECTRICAL INSTALLATION All types with the CE Mark include suppression devices providing transient protection to EN 61326 4 and EN 61326 2 3 Conformity with the requirements of the CE mark only applies when connection is made with Gems ...

Страница 3: ...ntee this instrument against faulty workmanship and material for a period of one year from date of delivery The Company undertake to repair free of charge ex works any instrument found to be defective within the specified period providing the instrument has been used within the specification in accordance with these instructions and has not been misused in any way Detailed notice of such defects a...

Страница 4: ...icer of the Company Any instrument returned without certification will be quarantined and no action will occur until cleared It may ultimately be returned to you and subject to a transportation charge MAINTENANCE Routine Inspection Not required except for periodic inspection of the cable and connector to ensure that these are neither damaged nor softened by incompatible liquid 560550 0064 Issue F ...

Страница 5: ... 1 2 3 E 2600A M2 YES MOULDED IMMERSIBLE R Y B W DRAIN 2600A F2 YES IMMERSIBLE IP67 R Y BL G 2600A 32 YES CONDUIT CABLE R W G BK 2600AU32 YES CONDUIT LEADS R W G BK 2600X 13 YES 8 4P A B D A C B D 2600X C3 YES 10 6P A B E A C B E 2600X G3 YES LARGE DIN 1 2 E 1 2 3 E 2600X M3 YES MOULDED IMMERSIBLE R BL DRAIN R W Y DRAIN 2600X F3 YES IMMERSIBLE IP67 R BK DRAIN R BK W DRAIN 2600X 33 YES CONDUIT CABL...

Страница 6: ...560550 0064 Issue F Page 6 of 7 ...

Страница 7: ...560550 0064 Issue F Page 7 of 7 ...

Отзывы: