1
OPERATING GUIDE for your
GEM-DXK2 KEYPAD
© NAPCO 2006
OI326 11/06
AC ON
READY
Страница 1: ...1 OPERATING GUIDE for your GEM DXK2 KEYPAD NAPCO 2006 OI326 11 06 AC ON READY ...
Страница 2: ... the highest industry standards To assure optimum safety and security familiarize yourself with this equipment Periodically check its condition and state of readiness by testing it at least once a week in both the ac battery and battery only modes ask your alarm professional how to make these tests INTRODUCTION IMPORTANT TEST YOUR SYSTEM WEEKLY Test your sounding device 1 While disarmed enter your...
Страница 3: ... PROGRAMMING 25 KEYPAD MESSAGES 28 GLOSSARY 32 SYSTEM TROUBLE ERROR CODES 35 TO SILENCE AN ALARM ENTER YOUR CODE AND PRESS U FOR SERVICE CALL _____________________ CENTRAL STATION _____________________ EXIT DELAY ___________________________ ENTRY DELAY _________________________ FIRE ALARM SOUND _____________________________________ BURGLAR ALARM SOUND _____________________________________ KEYPAD F...
Страница 4: ...4 R 1 2 3 B 4 5 6 C 7 8 9 0 P Q G U ARMED STATUS AC ON READY KEYPAD CONTROLS INDICATORS 2 3 4 5 6 7 8 9 10 11 12 1 ...
Страница 5: ...ctors Numerical Keys 1 9 0 Used to enter codes zone numbers etc ENTER Button Entry key Causes the entered code or selected function to be executed STAY Button 1 Bypasses all Interior Zones simultaneously STAY Mode to allow free movement within the premises Hold down P when the system is armed in STAY Mode to cancel entry delay on Exit Entry Zones causing an instant alarm upon violation 2 Scrolls t...
Страница 6: ...nnot locate or repair the problem yourself call for assistance If you cannot get immediate help bypass the problem zone s from the system by pressing B then the zone number or vice versa Note Bypassed zones are unprotected If armed with zones bypassed be sure to have the system checked as soon as possible 2 Arm the system Enter your code and press Q The green STATUS light will go off the red ARMED...
Страница 7: ...trouble Be sure to have the trouble repaired as soon as possible Silence Alarm If you enter your code while the alarm is sounding the message CAN T ARMSIL will be displayed The system will silence the alarm and will be ready to be armed again Alarm Sounding If you are attempting to arm with Easy Arm Optional and the alarm is sounding CAN T ARMSND will be displayed The alarm will not silence Only a...
Страница 8: ...access to other areas without the system status display This is NOT a high security feature To arm any area 1 Press the numerical key representing the area number 2 Press G followed by U In effect you will now be in that area 3 Enter your User Code followed by Q to arm or disarm the area Note Your code must be valid in that area 4 Press G followed by U to return to the home area Global Arming For ...
Страница 9: ... while the system is armed STAY By activating Easy Exit while the system is armed STAY the Exit Delay countdown will take place during which time you are permitted to leave through the exit door The Easy Exit Delay time will be identical to the Exit Delay time the system gives you each time it is armed STAY This will allow for example an early morning commuter to exit the house without having to d...
Страница 10: ... will appear for the GEM P9600 3200 panels Emergency Buttons Only available if programmed The Blue Emergency Buttons 7 8 9 if programmed are always active whether the system is armed or disarmed The emergency signal will only be transmitted when an Emergency Button and G are pressed at the same time Fire Emergency Simultaneously press 7 and G to alert the central station of a fire emergency Fire E...
Страница 11: ...n invalid code the keypad display Wrong Code Re enter your code immediately Alarm Indication Silencing an Alarm If the red ARMED light is flashing and ALARM is displayed an alarm occurred while you were out Proceed with caution If you suspect that an intruder may still be on the premises leave immediately and call authorities from a neighbor s phone To silence an audible alarm 1 Enter your code an...
Страница 12: ...ay Zone Day Zone s programmed YES NO A Day Zone is used to monitor a secured exit door window foil etc A problem on this type of burglary zone will cause a DAY ZN dis play followed by ZONEXX xx represents the zone number and a pulsing keypad sounder while disarmed To silence the sounder press C or arm and disarm if so programmed Correct the problem to reset the Day Zone 24 Hour Zone 24 Hour Zone s...
Страница 13: ...vidence of a fire enter your User Code and press U to turn off the alarm 4 Check smoke detector s If a smoke detector tripped its red alarm indicator light will be on After the alarm condition is corrected thermostat cooled down smoke cleared from detector etc pressing C again will reset the keypad within about 10 seconds Fire Zone Trouble 1 If a problem in the fire circuit is detected FIRE TB fir...
Страница 14: ...ith all those who use the building 1 In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals escape quickly Do not stop to pack 3 Test the door If it is hot use your alternate route through the window If the door is cool brace your shoulder against it and open it cautiously Be ready to slam the door if smoke or heat...
Страница 15: ...15 FIRE PROTECTION Floorplan Draw a plan of your premises in the space provided below Floorplan ...
Страница 16: ...res because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors will not detect oxygen levels smoke toxic gases or flames Therefore they may only be used as part of a comprehensive fire detection system in conjunction with other devices Under no circumstances should thermostatic heat d...
Страница 17: ...ition functions that are intended for use by the installer or servicer will not be displayed Note Functions may be manually scrolled forward or backward using R and B respectively Display Zone Status Identifies zones that are not secured Zones identified will auto scroll through the display window Press NEXT P and PRIOR Q to scroll bypassed zones Display Zones Bypassed Displays manually bypassed z...
Страница 18: ...ire Zone s Use NEXT and PRIOR to scroll fire troubles Activate Overview For GEM P9600 3200 panels only OPTIONAL Overview programmed for user YES NO In a partitioned system this mode displays the status of Areas 1 and 2 simultaneously The READY1 display will be replace by the OV display shown at left For each area R Area Ready z Zone Fault A Area Armed B Burglary Zone in Alarm F Fire Zone in Alarm ...
Страница 19: ...rror codes Start Exit Time OPTIONAL Start Exit Time programmed YES NO In Commercial Burglary systems exit delay may have been programmed to start after a central station ringback verification signal has been received If the ringback tone has not been received within about 30 seconds after arming a communication problem may exist Use the START EXIT TIME Function to start exit delay manually then ex...
Страница 20: ...d the key pad will begin a 15 minute countdown with the sounder pulsing During this time arm ing may be delayed an additional 1 to 4 hours as above or autoarming may be can celled by arming and disarming the panel Activate Program Program Mode programmed for user YES NO Activates the Program Mode from Keypad No 1 only Note This feature is disabled while armed Activate Download Activates the Manual...
Страница 21: ...t A display of Z01TAM tamper condition indicates that the case of the transmitter on Zone 1 is open A display of Z01SUP supervisory failure indicates that a test signal from the transmitter on Zone 1 has not been received Note Hold down G to recall the first line Relay Control OPTIONAL Turns on or off one or more programmed Relay Groups Press U to turn the displayed group on or off press NEXT to p...
Страница 22: ...p to 45 sec onds at your option by consulting with your installer Regular Burglary Non 24 Hour Zone reports are aborted by disarming within the delay period 24 Hour Zones and zones programmed to report restores must be restored first then the panel armed and disarmed all within the delay period Opening and or Closing Reporting Your system can notify the central station every time it is disarmed or...
Страница 23: ...seconds a communication problem may exist call for service The Start Exit Time function may then be used to manually start the exit delay however reporting capability may be sacrificed If your system does not report or the ringback feature was not programmed exit delay will start as soon as your code is entered Also note that if an exception window is programmed and the closing is within that wind...
Страница 24: ...24 NOTES ...
Страница 25: ... blue G button 6 The programmed code or description will not be permanently stored until you press U 7 To exit the Program Mode press C Programming User Codes Do not attempt to program a code contain ing any blank spaces between digits In selecting your codes do not program re petitive numbers 1111 consecutive numbers 1234 your birth date address or other obvious combinations Choose a code of up t...
Страница 26: ...t be saved 6 Press U to save the code in mem ory Repeat steps 3 6 for each user Note To void a code blank out each digit by pressing G 0 then press the Save U button Note Duplicate Codes are not allowed therefore a duplicate Code entered in the LCD Window will erase when U is pressed To Program User Codes 1 Using Number buttons enter User Number 2 Press R 3 Using number buttons enter User Code of ...
Страница 27: ... Press U to save the code 6 Press C to exit the Program Mode Notes Note Duplicate Codes are not allowed therefore a dupli cate Code entered in the LCD Window will erase when U is pressed If the system contains more than one keypad only the keypad designated No 1 may be used for programming if in doubt which is No 1 ask your installer While in Program Mode the ARMED and STATUS lights remain off and...
Страница 28: ...ates that Chime or Watch Mode is on Note If Watch Mode is programmed MONITOR ON will not display for Chime Mode Panel reporting to central station on arming If necessary wait for ringback signal before exiting Exit delay in progress XX denotes exit time remaining If displayed BYPASSED indicates arming with zones bypassed INSTANT ON indicates arming with Instant protection Entry delay in progress X...
Страница 29: ...ay Zone zone numbers will scroll Press C to silence sounder Note Watch Mode must be active Alarm Condition followed by zone number s ALARM and zones will display after sys tem is disarmed Note zones then press C to clear keypad The alarm signal has been cancelled during the Abort Delay before an alarm signal re port was sent to the central station If cancelled after the alarm signal report was sen...
Страница 30: ...oned systems only Code not valid for area For Commercial Systems Only Code not valid for programmed time window Wrong code entered or Easy Bypass function not enabled OPTIONAL In Manager s Mode Arming prevented due to unsecured zone represents number of area with unsecured zone Press area number then G and U to switch to that area with faulted zones s displayed The faulted zone can now be secured ...
Страница 31: ... checked in E05 01 Transmitter on Zone 1 has a low battery E15 01 Transmitter on Zone 1 has its case open tamper condition OPTIONAL Commercial Systems Only Overview Mode Simultaneously shows status of Areas 1 and 2 R Area Ready Z Zone Fault A Area Armed B Bur glary Zone in Alarm F Fire Zone in Alarm T Fire Trouble c Check Trouble Area in Function Display Mode Commercial Systems Only Remote access ...
Страница 32: ...ning the system on off by entering your code at the keypad then pressing U Battery Backup power source in the control panel enclosure to provide protection in the event of a power failure BYPASS Button Enables you to manually remove one or more protective zones from the system Central Station Monitors incoming reports and emergency messages from a digital communicator and notifies the proper autho...
Страница 33: ... into two or more up to eight independent subsystems areas Pre Alarm Warning A keypad sounder alert of an impending alarm This option is programmable by zone for the same duration as that programmed for Abort Delay see Abort Delay Report A transmission to a central station notifying of a change in the status of the system alarm trouble low battery etc Ringback A beep after arming verifying the cen...
Страница 34: ...r Zone Provides exit and entry delay for interior devices Entry delay only occurs if re entry takes place through the normal exit entry door first Fire Zone Detects fire alarms or trouble conditions Interior Zones Circuits within the premises usually including space protection devices interior doors etc but not exterior doors or windows These can all be bypassed simultaneously by pressing and hold...
Страница 35: ... Keypad Response Failure NN Keypad Number E11 NN Keypad Tamper Condition NN Keypad Number E12 NN Expansion Zone Module Re sponse Failure NN Module Number E13 NN Expansion Zone Module Tam per Condition NN Module Number E14 NN Relay Board Response Fail ure NN Relay Board Num ber E15 NN RF Transmitter Tamper Condi tion NN Transmitter Num ber E16 NN Receiver Jammed NN Re ceiver Number E17 NN Receiver ...
Страница 36: ...o any or all of the following criminal tampering electrical or communications disruption it is possible for the system to fail to perform as expected NAPCO does not represent that the product system may not be compromised or circumvented or that the product or system will prevent any personal injury or property loss by burglary robbery fire or otherwise nor that the product or system will in all c...