background image

This device is warranted against all construction or operating defects for a period of 12

months of the date of manufacture given on the warranty label on the back. If this label is

missing the warranty loses its validity. The manufacturer assumes no responsibility for

anomalies or failures caused by transport or extraneous causes such as electric discharge,

over voltage, mechanical impact, flooding, or due to improper installation or non compliance

with the technical data specified. The alarm has only dissuasive functions against theft.

To replace the battery proceed as follows:

1. Access the programming function (see paragraph 3.1 in the installation manual). In these

conditions, in fact, the control unit does not detect the sabotage alarm caused by the

opening of the sensor.

2. Open the sensor cover by pulling out the cap at the centre of the cover and removing

the fastening screw underneath.

3. Replace the battery and, if desired, check the radio transmission (SYSTEM TEST).

4. Close the cover.

5. Quit the programming function.

TECHNICAL DATA

Power supply

12V alkali battery

Current drained in resting conditions

2µA

Operation with battery charged

ca 1 year

Range of transmitter in free air

20 m

Transmission frequency

433.92 MHz

5000IS-CM - Rev. 00 / 01/ 02

5000CM

 

5000IS-CM - Rev. 00 / 01/ 02

This device is warranted against all construction or operating defects for a period of 12

months of the date of manufacture given on the warranty label on the back. If this label is

missing the warranty loses its validity. The manufacturer assumes no responsibility for

anomalies or failures caused by transport or extraneous causes such as electric discharge,

over voltage, mechanical impact, flooding, or due to improper installation or non compliance

with the technical data specified. The alarm has only dissuasive functions against theft.

To replace the battery proceed as follows:

1. Access the programming function (see paragraph 3.1 in the installation manual). In these

conditions, in fact, the control unit does not detect the sabotage alarm caused by the

opening of the sensor.

2. Open the sensor cover by pulling out the cap at the centre of the cover and removing

the fastening screw underneath.

3. Replace the battery and, if desired, check the radio transmission (SYSTEM TEST).

4. Close the cover.

5. Quit the programming function.

TECHNICAL DATA

Power supply

12V alkali battery

Current drained in resting conditions

2µA

Operation with battery charged

ca 1 year

Range of transmitter in free air

20 m

Transmission frequency

433.92 MHz

5000CM 

Отзывы: