According to IEC N°364 publication,
the pump must be installed at minimum 2
meters from the swimming pool edge.
3.1 Ventilation:
The pump’s motor is cooled
by fan, placed in the back side. You should
install the pump in a well ventilated place
(free from possible freezing), preferably in a
room.
a) If the pump is installed outdoors, it must be
protected with suitable cover.
b) If the pump is installed in a buried or
semiburied “case”, it is necessary to assure a
sufficient air entrance in order the motor
ventilation not to be damaged (the inside
temperature shoul
d not exceed the 50°C).
4. ELECTRICAL CONNECTIONS
Please make sure that the electrical
supply is interrupted nefore removing the
connection case cover or before any moving or
disassembling of the pump.
Electrical connections must be done by a
Professional and according to the local
standarts.
The pump must be connected to an external
switch.
The voltage and frequency are marked on the
characteristics plate. Please make sure that the
motor is suitable to electrical supply in the
network.
The motor should be connected to the electrical
supply as shown in the drawing, using a suitable
cable (watertight approved) and in accordance
to the local standarts.
4.1 Motor Protection:
All version must be
connected to an external motor protector.
The pump must be connected to the outlet
mass and electircal installation must have a
differential circuit.