INSTRUCTION FOR PVC APPLICATION 

Cutting and chamfering: 

Pipe should be cut square. A simple method of cutting pipes square is to wrap newspaper or similar 
sheet paper around the pipe with no overlap of the edges. Mark line around pipe (felt pen is ideal). Cut 
to line with a fine toothed saw. 
Pipe ends should be chamfered at an angle of approximately 15° to about 

 

of the wall thickness with 

a coarse file, surform tool or chamfering tool. 

Solvent Weld Joints 

Pipes up to 75mm may be jointed easily with solvent adhesives. Larger sizes require special 
techniques 
and require two men to make such joints. 
1. Jointing Procedure. Mark depth of entry of the pipe into the socket and alignment mark. 
2. Make small chamfer on the edge of the pipe end with medium file. 
3. Roughen the outside of the pipe and the inside of the socket using sand paper or emery cloth up 
to the entry mark. 
4. Clean both surfaces and remove all dust, grease and swarf using a dry clean cloth and cleaner. 
5. Stir adhesive thoroughly. 
6. Apply adhesive without delay after cleaning, using a flat clean brush. Apply an even unbroken 
layer brushing axially to the pipe end and socket mouth with a heavier layer on the pipe. Where 
loose fits are found, the pipe should be given a second coat. 
7. Immediately insert the pipe into the socket up to the entry mark, align pipe and twist 90 degrees. 
Hold in position for a few seconds, then wipe off excess adhesive. 
Solvent Weld jointing of large diameter pipes require special care and our Technical Service 
Department should be contacted in case of difficulty. Always replace the lid of the can after making a 
joint and follow the instructions on the can observing any warnings. 
Joints should not be moved or disturbed for 10-15 minutes then the jointed pipe may be handled with 

Содержание PUMPEX-100M

Страница 1: ...GEMAS COUNTER CURRENT SYSTEM USER MANUAL ...

Страница 2: ...e 50 C 2 2 Water Temparature From 0 C to 50 C 2 3 Maximum working pressure permitted 2 Bar Note The ram crash to be lower that 3kgs 2 4 Maximum inlet pressure When the pump Works with a closed valve the inlet pressure should be lower than the maximum working pressure permitted always 2 5 Minimum suction pressure Type Maximum Suction Maximum Autosuction Pumpex 5m 4 m 2 6 Self Priming The PUMPEX pum...

Страница 3: ...g The pipes should be fitted in such a way that any pressure varioation caused by temperature changes do not effect the pump If the piping is very long and or high support the pump in front and behind It is reccomendable to put a retention or check valve at the outlet In case of using a suction hose it must be non compressible with a reinforcement spiral The suction pipe hose should be the shortes...

Страница 4: ...TIONS Please make sure that the electrical supply is interrupted nefore removing the connection case cover or before any moving or disassembling of the pump Electrical connections must be done by a Professional and according to the local standarts The pump must be connected to an external switch The voltage and frequency are marked on the characteristics plate Please make sure that the motor is su...

Страница 5: ... is isterrupted and it is not possible to be connected accidentally before to start working with the pump The filter basket must be checked daily and cleaned if necessary Before opening the prefilter cover please close the suction and discharge valves After the filter basket cleaning clean also the filter cover gasket and put it in its place Then check if the pump housing is full of water and if s...

Страница 6: ...ANCE Please make sure that the electrical supply is interrupted and it is not possible to be accidentaly connected before the pump to start working The pump is designed to operate maintenance under normal working conditions The motor bearings are permanently lubricated ...

Страница 7: ......

Страница 8: ......

Страница 9: ...INSTALLATION MUST BE DONE ACCORDING TO BELOW INSTRUCTION ...

Страница 10: ......

Страница 11: ... and the inside of the socket using sand paper or emery cloth up to the entry mark 4 Clean both surfaces and remove all dust grease and swarf using a dry clean cloth and cleaner 5 Stir adhesive thoroughly 6 Apply adhesive without delay after cleaning using a flat clean brush Apply an even unbroken layer brushing axially to the pipe end and socket mouth with a heavier layer on the pipe Where loose ...

Страница 12: ...on the containers When laying continuous runs of pipe joints may be made quicker than the setting times advised above The joint will not be disturbed with long lengths providing that the pipe is not twisted or the previously made joint lifted out of place Rubber Ring Joints Ensure that the spigot and socket are free from dust grit grease and as dry as possible Insert pipe into the socket without s...