Cinterion
®
ELS31-VA/ELS51-VA Hardware Interface Description
4.2 Mounting ELS31-VA/ELS51-VA onto the Application Platform
92
ELS31-VA_ELS51-VA_HID_v01.000
2017-01-04
Confidential / Preliminary
Page 84 of 106
4.2.4
Durability and Mechanical Handling
4.2.4.1
Storage Conditions
ELS31-VA/ELS51-VA modules, as delivered in tape and reel carriers, must be stored in sealed,
moisture barrier anti-static bags. The conditions stated below are only valid for modules in their
original packed state in weather protected, non-temperature-controlled storage locations. Nor-
mal storage time under these conditions is 12 months maximum.
Table 24:
Storage conditions
Type
Condition
Unit
Reference
Air temperature: Low
High
-25
+40
°C
IPC/JEDEC J-STD-033A
Humidity relative: Low
High
10
90 at 40°C
%
IPC/JEDEC J-STD-033A
Air pressure: Low
High
70
106
kPa
IEC TR 60271-3-1: 1K4
IEC TR 60271-3-1: 1K4
Movement of surrounding air
1.0
m/s
IEC TR 60271-3-1: 1K4
Water: rain, dripping, icing and
frosting
Not allowed
---
---
Radiation:
Solar
Heat
1120
600
W/m
2
ETS 300 019-2-1: T1.2, IEC 60068-2-2 Bb
ETS 300 019-2-1: T1.2, IEC 60068-2-2 Bb
Chemically active substances
Not
recommended
IEC TR 60271-3-1: 1C1L
Mechanically active substances Not
recommended
IEC TR 60271-3-1: 1S1
Vibration sinusoidal:
Displacement
Acceleration
Frequency range
1.5
5
2-9 9-200
mm
m/s
2
Hz
IEC TR 60271-3-1: 1M2
Shocks:
Shock spectrum
Duration
Acceleration
Semi-sinusoidal
1
50
ms
m/s
2
IEC 60068-2-27 Ea