Cinterion
®
EHS6 AT Command Set
2.12 AT^SCFG
EHS6_ATC_V03.001
15/12/3
Confidential / Released
Page 66 of 513
GPIO20 - GPIO23. IMPORTANT: Audio commands offer full functionality only if the DAI is enabled with
="GPIO/mode/DAI","std". If DAI resources are not available then DAI dependent audio commands will
respond "+CME ERROR: operation not allowed".
The changes will take effect after restart of the ME and are non-volatile.
“std“
Signal lines are assigned to this interface.
“gpio“
Signal lines are used as GPIO.
“rsv“
Signal lines are reserved by other interface. This value cannot be set by the
write command.
GPRS with AutoAttach
This parameter can be used to control whether the ME will perform a GPRS attach immediately after power-up
and registering to the network or not. If the setting is changed to "enabled" and the ME is not attached yet, it will
not initiate an attach immediately but after the next power-up and registration to the network.
If the setting is changed to "disabled" and there is no PDP context activated, the ME will detach automatically.
Parameter is global for all interfaces, non-volatile and will not be reset by
.
“disabled“
GPRS auto attach is disabled
“enabled“
(D)
GPRS auto attach is enabled
CFUN Mode
Parameter determines whether the
values for Normal mode and Airplane mode are
stored persistently.
“0“
(D)
Setting of
parameter
is stored persistently.
“1“
is volatile, i.e. changes are not reestab-
lished after restart.
Saved CFUN Mode
Indicates
parameter
which will be used for next ME restart.
Manufacturer name
Setting can be used to configure the name of the manufacturer which is displayed with the commands
and
. Maximal length of the Manufacturer name is 25 characters (or less if you use multibyte characters).
“Cinterion“
(D)
Product name
Setting can be used to configure the name of the product which is displayed with the commands
and
. Maximal length of the product name is 25 characters (or less if you use multibyte characters).
“EHS6“
(D)
<gaa>
(str)(+CSCS)(NV)
<cfun>
(str)(NV)
<cfun_save>
(str)(NV)
<manufacturer>
(str)(NV)
<product>
(str)(NV)